ASTM D6634 D6634M-2014 7148 Standard Guide for the Selection of Purging and Sampling Devices for Groundwater Monitoring Wells《选择地下水监测井用净化和取样设备的标准指南》.pdf
《ASTM D6634 D6634M-2014 7148 Standard Guide for the Selection of Purging and Sampling Devices for Groundwater Monitoring Wells《选择地下水监测井用净化和取样设备的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6634 D6634M-2014 7148 Standard Guide for the Selection of Purging and Sampling Devices for Groundwater Monitoring Wells《选择地下水监测井用净化和取样设备的标准指南》.pdf(15页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6634/D6634M 14Standard Guide forSelection of Purging and Sampling Devices for GroundwaterMonitoring Wells1This standard is issued under the fixed designation D6634/D6634M; the number immediately following the designation indicates theyear of original adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This guide describes the characteristics and operatingprinciples of purging and sampling devices avail
3、able for use ingroundwater monitoring wells and provides criteria for select-ing appropriate devices for specific applications. The selecteddevice(s) should be capable of purging the well and providingvalid representative samples of groundwater and includeddissolved constituents. The scope does not
4、include proceduresfor purging or collecting samples from monitoring wells,sampling devices for non-aqueous phase liquids, diffusion-typesampling devices or sampling from devices other than moni-toring wells.1.2 This guide reviews many of the most commonly useddevices for purging and sampling groundw
5、ater monitoringwells. The practitioner should ensure that the purging andsampling methods used, whether or not they are addressed inthis guide, are adequate to satisfy the monitoring objectives ateach site.1.3 This guide offers an organized collection of informationor a series of options and does no
6、t recommend a specific courseof action. This guide cannot replace education or experienceand should be used in conjunction with professional judgment.Not all aspects of this guide may be applicable in all circum-stances. This ASTM guide is not intended to represent orreplace the standard of care by
7、which the adequacy of a givenprofessional service must be judged, nor should this documentbe applied without consideration of the many unique aspects ofa project. The word “Standard” in the title of this documentmeans only that the document has been approved through theASTM consensus process.1.4 The
8、 values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the sta
9、ndard. Dimensions provided are typical.1.5 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory l
10、imitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D653 Terminology Relating to Soil, Rock, and ContainedFluidsD3740 Practice for Minimum Requirements for AgenciesEngaged in Testing and/or Inspection of Soil and Rock asUsed in Engineering Design and ConstructionD5088 Practice for Dec
11、ontamination of Field EquipmentUsed at Waste SitesD6452 Guide for Purging Methods for Wells Used forGroundwater Quality Investigations3. Terminology3.1 Definitions: For definitions of general terms used withinthis guide, refer to Terminology D653.4. Summary of Guide4.1 The primary objective of groun
12、dwater sampling pro-grams is to obtain samples that are representative of existinggroundwater conditions retaining the physical and chemicalproperties of the groundwater in a specific water-bearing zone.3Depending on the purging and sampling protocol, this mayrequire that the well is purged of stagn
13、ant water, or until1This guide is under the jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Groundwater andVadose Zone Investigations.Current edition approved Feb. 1, 2014. Published February 2014. Originallyapproved in 2001. Last previous
14、 edition approved in 2006 as D6634 01 (2006).DOI: 10.1520/D6634_D6634M-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、ASTM website.3For example, the plasticizers in flexible PVC can contaminate samples withphthalate esters. The use of silicone rubber tubing, which contains no plasticizers,can obviate this problem; however, the potential for sample bias due to sorption/desorption exists with both materials (1). Thes
16、e pumps can be used with theintermediate vessel system described above, so that the sample contacts only theintake tubing and vessel avoiding contact with the pump mechanism tubing.Alternatively, using silicone rubber tubing at the pump head only can minimize thisproblem (2, 3).*A Summary of Changes
17、 section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1pre-determined purging criteria are met. Therefore, device(s)selected for use in groundwater sampling programs must becapable of purging the w
18、ell as needed or delivering to thesurface, or both, a sample representative of in-situ groundwaterconditions. A number of factors can influence whether or not aparticular sample or set of samples is representative, and one ofthe significant elements of sample collection protocols is thesampling mech
19、anism (4, 5, 6).44.2 In selecting a purging or sampling device, or both, foruse in a groundwater monitoring well, a number of factorsmust be considered.Among these are 1) outside diameter of thedevice; 2) materials from which the device and associatedequipment are made; 3) overall impact of the devi
20、ce ongroundwater sample integrity with respect to the analytes ofinterest; 4) ability to regulate the discharge rate of the device;5) depth to water; 6) ease of operation and servicing; 7)reliability and durability of the device; 8) portability of thedevice and any needed accessory equipment, if app
21、licable; 9)other operational limitations of the device; and 10) initial andoperating cost of the device and accessory equipment. Basedon these considerations, each of the devices available forpurging or sampling groundwater, or both, from monitoringwells has its own unique set of advantages and limi
22、tations.NOTE 1The quality of the result produced by this guide is dependenton the competence of the personnel performing it, and the suitability of theequipment and facilities used. Agencies that meet the criteria of PracticeD3740 are generally considered capable of competent and objectivetesting/sa
23、mpling/inspection/etc. Users of this guide are cautioned thatcompliance with Practice D3740 does not in itself ensure reliable results.Reliable results depend on many factors; Practice D3740 provides a meansof evaluating some of those factors.5. Significance and Use5.1 Appropriate purging and sampli
24、ng equipment must beused to make sure that samples collected from monitoringwells represent the groundwater chemistry of the desired waterbearing zone.5.2 This guide is intended to be a common reference forpurging and sampling devices. It can be applied to groundwaterquality sampling from monitoring
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6634D6634M20147148STANDARDGUIDEFORTHESELECTIONOFPURGINGANDSAMPLINGDEVICESFORGROUNDWATERMONITORINGWELLS

链接地址:http://www.mydoc123.com/p-523107.html