ASTM D7008-2003 Standard Specification for Geosynthetic Alternate Daily Covers《土工合成日常备用覆盖层的标准规范》.pdf
《ASTM D7008-2003 Standard Specification for Geosynthetic Alternate Daily Covers《土工合成日常备用覆盖层的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7008-2003 Standard Specification for Geosynthetic Alternate Daily Covers《土工合成日常备用覆盖层的标准规范》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 7008 03Standard Specification forGeosynthetic Alternate Daily Covers1This standard is issued under the fixed designation D 7008; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements for reusableand nonreusable geosynthetic alternate daily covers (ADCs)used on the working face of mun
3、icipal solid waste landfills(MSWLF). Geosynthetic ADCs include a wide range ofproducts including, but not limited to, reinforced film, unrein-forced film, reinforced sheet, unreinforced sheet, coated geo-textile and uncoated geotextile.1.2 This standard addresses the base ADC materials anddoes not a
4、ddress grommets, straps or other fabricated parts.1.3 The values stated in SI units are to be regarded as thestandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-pria
5、te safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced Documents2.1 ASTM Standards:D 882 Test Methods for Tensile Properties of Thin PlasticSheetingD 1004 Test Method for Initial Tear Resistance of PlasticFilm and SheetingD 4355 Test Met
6、hod for Deterioration of Geotextiles byExposure to Light, Moisture and Heat in a Xenon Arc TypeApparatusD 4439 Terminology for GeosyntheticsD 4533 Test Method for Trapezoid Tearing Strength ofGeotextilesD 4632 Test Method for Grab Breaking Load and Elonga-tion of GeotextilesD 4833 Test Method for In
7、dex Puncture Resistance ofGeotextiles, Geomembranes and Related ProductsD 6523 Guide for Evaluation and Selection of AlternativeDaily Covers (ADCs) for Sanitary LandfillsE 96 Test Methods for Water Vapor Transmission of Mate-rials2.2 Other Standards:National Fire Protection Association (NFPA) 701 St
8、andardMethods of Fire Tests for Flame Propagation of TextilesGeosynthetic Research Institute (GRI) SpecificationGM11 Accelerated Weathering of Geomembranes using aFluorescent UVA-Condensation Exposure Device3. Terminology3.1 DefinitionsFor definitions of terms related to geosyn-thetics, refer to Ter
9、minology D 4439.3.1.1 alternate daily cover, nan alternative to the tradi-tional 15 cm (6 in.) soil cover required by the USEPA forlandfill working faces to “control disease vectors, fires, odors,blowing liter, and scavenging, without presenting a threat tohuman health and the environment.”3.1.2 fir
10、e retardant, adjin geosynthetic ADCs, meeting therequirements of NFPA 701, Method 1, Standard Method of FireTests for Flame Propagation of Textiles and Films.3.1.3 nonreusable, adjin geosynthetics, a fabric or filmintended to be placed once and then disposed of, discarded, orleft in place.3.1.4 reus
11、able, adjin geosynthetics, a fabric or membranematerial intended to be retrieved and installed more than onceto perform the cover function.3.1.5 working face, nthe area of a landfill in which wasteis actively being deposited.4. Classification of Geosynthetic ADCs4.1 NonreusableNonreusable geosynthet
12、ic ADCs consistof disposable films or geotextiles, intended to be left in placewithout retrieval. Special equipment exists to facilitate theplacement and anchoring of these materials to cover theworking face of landfills. The cover may contain pro-degradantadditives to accelerate degradation within
13、the waste to allowthe free flow of fluids and gases within the waste mass. Threeclasses of nonreusable ADCs are specified based on tensile,tear and puncture properties (see Table 1).4.2 ReusableReusable geosynthetic ADCs consist of vari-ous types of fabric or plastic membranes that have either beend
14、eveloped or adapted for use as a daily cover material. Panelsfabricated from these materials are placed over the workingface at the end of the day, and retrieved prior to the start of thenext operating day. Special mechanized equipment can be usedto facilitate the placement and retrieval of panels.
15、Three classes1This specification is under the jurisdiction of ASTM Committee D35 onGeosynthetics and is the direct responsibility of Subcommittee D35.03 on Perme-ability and Filtration.Current edition approved Dec. 1, 2003. Published February 20041Copyright ASTM International, 100 Barr Harbor Drive,
16、 PO Box C700, West Conshohocken, PA 19428-2959, United States.of reusable ADCs are specified based on tensile, tear andpuncture properties (see Table 2).4.3 Fire RetardantMeets the requirements of 6.4.4.4 UV ResistantMeets the requirements of 6.5.5. Physical Properties5.1 GeneralIn order to gain the
17、 approval of regulatoryagencies, ADCs must be demonstrated to be equivalent to soildaily cover with respect to controlling odor, blowing litter,disease vectors, scavengers and fire. Reusable ADCs must alsohave the strength and durability to withstand multiple uses, fora duration of one year. If nonr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70082003STANDARDSPECIFICATIONFORGEOSYNTHETICALTERNATEDAILYCOVERS 土工 合成 备用 覆盖层 标准规范 PDF

链接地址:http://www.mydoc123.com/p-524234.html