1、Designation: D 5055 09Standard Specification forEstablishing and Monitoring Structural Capacities ofPrefabricated Wood I-Joists1This standard is issued under the fixed designation D 5055; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 GeneralThis specification gives procedures for estab-lishing, monitoring, and reevaluating structural
3、 capacities ofprefabricated wood I-joists. Capacities considered are shear,reaction, moment, and stiffness. Procedures for establishingcommon details are given and certain design considerationsspecific to wood I-joists are itemized.1.2 Contents of the StandardAn index and brief descrip-tion of the m
4、ain features of this specification are given inX1.1.1.1.3 Development of the StandardThe development andintent of this specification is discussed in Appendix X1.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI
5、units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determi
6、ne the applica-bility of regulatory limitations prior to use. A specific precau-tionary statement is given in 6.1.1.5.2. Referenced Documents2.1 ASTM Standards:2D 198 Test Methods of Static Tests of Lumber in StructuralSizesD 245 Practice for Establishing Structural Grades and Re-lated Allowable Pro
7、perties for Visually Graded LumberD 1990 Practice for Establishing Allowable Properties forVisually-Graded Dimension Lumber from In-Grade Testsof Full-Size SpecimensD 2559 Specification for Adhesives for Structural Lami-nated Wood Products for Use Under Exterior (Wet Use)Exposure ConditionsD 2915 Pr
8、actice for Evaluating Allowable Properties forGrades of Structural LumberD 4761 Test Methods for Mechanical Properties of Lumberand Wood-Base Structural MaterialD 5456 Specification for Evaluation of Structural Compos-ite Lumber ProductsD 5457 Specification for Computing Reference Resistanceof Wood-
9、Based Materials and Structural Connections forLoad and Resistance Factor DesignD 7247 Test Method for Evaluating the Shear Strength ofAdhesive Bonds in Laminated Wood Products at ElevatedTemperaturesE4 Practices for Force Verification of Testing MachinesE 529 Guide for Conducting Flexural Tests on B
10、eams andGirders for Building ConstructionE 699 Practice for Evaluation of Agencies Involved inTesting, Quality Assurance, and Evaluating of BuildingComponentsIEEE/ASTM SI 10 Standard for Use of the InternationalSystem of Units (SI): The Modern Metric System2.2 U.S. Product Standards:3PS-1 Structural
11、 PlywoodPS-2 Performance Standard for Wood-Based Structural-UsePanels2.3 Other Standards:CSA O86 Engineering Design in Wood4CSA Standards for Wood Adhesives O112 SeriesCSA O151 Canadian Softwood Plywood4CSA O325 Construction Sheathing4Lumber Grading Rules Approved by American LumberStandards Committ
12、ee (ALSC) or Canadian Lumber Stan-dards Accreditation Board (CLSAB)5SPS-4 Special Products Standard for Fingerjointed Flange1This specification is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.02 on Lumber and EngineeredWood Products.Current
13、 edition approved March 1, 2009. Published April 2009. Originallyapproved in 1990. Last previous edition approved in 2008 as D 5055 08ae1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
14、information, refer to the standards Document Summary page onthe ASTM website.3Available from APAThe Engineered Wood Association, 7011 South 19thStreet, Tacoma, WA98466, http:/www.apawood.org; and TECO, 2902 Terra Court,Sun Prairie, WI 53590, http:/.4Available from Canadian Standards Association (CSA
15、), 5060 Spectrum Way,Mississauga, ON L4W 5N6, Canada, http:/www.csa.ca.5Available from American Lumber Standard Committee (ALSC), P.O. Box 210,Germantown, MD 20874, http:/www.alsc.org; and Canadian Lumber StandardsAccreditation Board (CLSAB), 960 Quayside Drive, Suite 406, New Westminster,BC V3M 6G2
16、, Canada, http:/www.clsab.ca.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Stock Lumber, 200163. Terminology3.1 Definition:3.1.1 prefabricated wood I-joista structural membermanufactured using sawn or structural composite lumberfla
17、nges and structural panel webs, bonded together with exte-rior exposure adhesives, forming an “I” cross-sectional shape.These members are primarily used as joists in floor and roofconstruction.3.2 Definitions of Terms Specific to This Standard:3.2.1 capacity (or structural capacity)the numeric resul
18、tof certain calculations specified in this specification.3.2.2 design valuethe numeric value claimed by themanufacturer as appropriate for use in structural analysis.NOTE 1A brief discussion of this issue is found in X1.9.3.2.3 structural composite lumbera composite of woodelements (for example, woo
19、d strands, strips, veneer sheets, ora combination thereof), bonded with an exterior grade adhesiveand intended for structural use in dry service conditions.4. Design Considerations4.1 Design Value Adjustments:4.1.1 Duration of LoadWith the exception of reactiondesign values limited by compression pe
20、rpendicular to grain,prefabricated wood I-joists shall be designed using the strengthadjustment for load duration used in sawn lumber. Thisadjustment is determined in accordance with the section onDuration of Load Under Modification of Allowable Propertiesfor Design Use in Practice D 245.4.1.2 Repet
21、itive MembersThe repetitive member factorfor prefabricated I-joists shall be taken as 1.0.NOTE 2Committee D07 chose to reduce the repetitive member factorto unity primarily for purposes of design simplicity. A discussion of thisdecision is given in Appendix X1.4.1.3 TreatmentsSome pressure treatment
22、s affect materialstrength and the quality of prefabricated wood I-joists. TreatedI-joists shall not be used without evaluation of such effects.4.1.4 EnvironmentThe capacities developed in this speci-fication are applicable to joists used under dry conditions suchas in most covered structures.Appropr
23、iate adjustments for usesin other environments shall be made.4.2 Shear Design:4.2.1 Neglecting loads within a distance from the supportequal to the depth of the member shall not be permitted.4.2.2 Adjustments to the shear design value near the supportor at locations of continuity or where reinforcem
24、ents areprovided must be substantiated by independent testing to thegeneral intended criteria for shear capacity herein.5. Materials5.1 Flange Stock:5.1.1 All flange material shall conform to the requirementsof 6.4. In addition, when the flange material is structuralcomposite lumber, the following p
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD50552009STANDARDSPECIFICATIONFORESTABLISHINGANDMONITORINGSTRUCTURALCAPACITIESOFPREFABRICATEDWOODIJOISTSPDF

链接地址:http://www.mydoc123.com/p-518741.html