ASTM D4597-2010 Standard Practice for Sampling Workplace Atmospheres to Collect Gases or Vapors with Solid Sorbent Diffusive Samplers《用固体吸附剂扩散采样器从工作地点大气中采集气体或蒸气样品的标准操作规程》.pdf
《ASTM D4597-2010 Standard Practice for Sampling Workplace Atmospheres to Collect Gases or Vapors with Solid Sorbent Diffusive Samplers《用固体吸附剂扩散采样器从工作地点大气中采集气体或蒸气样品的标准操作规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4597-2010 Standard Practice for Sampling Workplace Atmospheres to Collect Gases or Vapors with Solid Sorbent Diffusive Samplers《用固体吸附剂扩散采样器从工作地点大气中采集气体或蒸气样品的标准操作规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4597 10Standard Practice forSampling Workplace Atmospheres to Collect Gases orVapors with Solid Sorbent Diffusive Samplers1This standard is issued under the fixed designation D4597; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the sampling of workplace atmo-spheres for the presence of certain gases
3、 or vapors by means ofdiffusion across a specified quiescent region and subsequentsorption on a solid sorbent (1).21.2 A list of organic compounds which are applicable tosolid sorbent sampling where the sorbent is contained in a bedthrough which air is passed is given in Annex A1 of PracticeD3686. D
4、iffusive samplers may be applicable to a similarrange of compounds but this must be confirmed by reference tothe individual sampler manufacturers literature.1.3 The valid use of diffusive samplers depends on theexistence of actual laboratory or field validation, or both.Guidance on validation can be
5、 obtained from published proto-cols (2-6). This practice is not designed to cover the verifica-tion, validation, or specific test procedures used to assess theaccuracy or precision of diffusive samplers.1.4 The values stated in SI units shall be regarded as thestandard.1.5 This standard does not pur
6、port to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D1
7、356 Terminology Relating to Sampling and Analysis ofAtmospheresD3686 Practice for Sampling Atmospheres to Collect Or-ganic Compound Vapors (Activated Charcoal Tube Ad-sorption Method)D3687 Practice for Analysis of Organic Compound VaporsCollected by the Activated Charcoal Tube AdsorptionMethodD6306
8、Guide for Placement and Use of Diffusion Con-trolled Passive Monitors for Gaseous Pollutants in IndoorAir2.2 Other Document:4Title 29CFR 1910.1000 Subpart Z Occupational Health andSafety Standard3. Terminology3.1 Terminology D1356 contains definitions of terms usedin this practice.3.2 Definitions of
9、 Terms Specific to This Standard:3.2.1 diffusionthe movement of gas or vapor moleculesfrom a region of high concentration to a region of lowconcentration as described by Ficks first law (8.1).3.2.2 diffusive samplerassembly used for sampling gas orvapor molecules from the atmosphere.3.2.3 sampling r
10、atethe ratio of mass of a given compoundcollected by a diffusive sampler per unit time of exposure to theconcentration of that compound in the atmosphere beingsampled. The sampling rate is sometimes referred to as theuptake rate. Units are ng (or mg)/ mg/m3/min (or h), which aredimensionally equival
11、ent to a volume flow-rate (for examplecm3/min).4. Summary of Practice4.1 Molecules (gases and vapors) are sampled from theatmosphere by a diffusive sampler. During the samplingprocess, the molecules diffuse from the environment adjacentto the sampler through a region of defined geometric structurean
12、d into a region containing the sorbent medium. The theory ofdiffusive sampling is given in this practice.4.2 Instructions are given for the correct use of the samplingdevices to enable their field application.4.3 Information on the calculation of environmental concen-tration based on sampler assay i
13、s given.1This practice is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.04 on Workplace Air Quality.Current edition approved Nov. 1, 2010. Published January 2011. Originallyapproved in 1987. Last previous edition approved in 2010 as D
14、4597 03(2009)1.DOI: 10.1520/D4597-10.2The boldface numbers in parentheses refer to the list of references at the end ofthis practice.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume infor
15、mation, refer to the standards Document Summary page onthe ASTM website.4Code of Federal Regulations, available from U.S. Government Printing Office,Washington, DC 20402.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance
16、 and Use5.1 Regulations such as those promulgated by the U.S.Occupational Safety and Health Administration in 29 CFR1910.1000 designate that certain hazardous gases and vaporsmust not be present in the workplace air at concentrationsabove specific values.5.2 This practice, when used in conjunction w
17、ith an analyti-cal technique, such as that given for organic compounds inPractice D3687, may provide a means for the determination oftime-weighted airborne concentrations of many of the hazard-ous gases and vapors in applicable regulations (for example,29CFR 1919.1000,), as well as others.5.3 The ma
18、nufacturers literature should be consulted forthe appropriate list of chemicals which may be sampled by aparticular device.6. Interferences6.1 The diffusive sampling process can be jeopardized byphysical blockage of entrances to the interior of the device suchas by liquid droplets or dust particles.
19、6.2 The diffusive sampling process can be jeopardized bystructural damage to any membranes or other elements used tocontrol either the geometry of the diffusion path or turbulencewithin the diffusion path.6.3 The diffusive sampling process can be jeopardized byair movement within the diffusion path.
20、 Recent sampler de-signs have incorporated elements to decrease this possibility.6.4 The diffusive sampling process can be jeopardized byinsufficient mixing of the air external to the sampler. This isknown as starvation. The manufacturer should provide arecommended minimum ambient air velocity, belo
21、w which thesampler should not be used.6.5 The diffusive sampling process can be jeopardized if theconcentration in air at the sorbent interface becomes sufficientto significantly alter the diffusion gradient within the diffusionpath. This can occur through sorbent saturation, either from thepresence
22、 of competing species (which may include water vapormolecules), or the selection of an inappropriate sorbent mate-rial for the concentration and time of exposure, or by increasedtemperature. The manufacturer should provide, or the usershould determine, the range of conditions over which signifi-cant
23、 bias from sorbent saturation will not occur.6.6 Errors may arise in estimating exposure using diffusivesamplers in instances in which the concentration of the gas orvapor being sampled varies significantly over time.6.7 Where multiple gases or vapors are sampled simulta-neously, care must be exerci
24、sed to ensure there is no mutualinterference in the analytical method chosen.7. Apparatus7.1 Diffusive Sampling Devices:7.1.1 A diffusive sampler consists of a cavity or group ofcavities containing air and terminated at one end by a sorbentsubstrate and opening at the other to the environment. Theca
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD45972010STANDARDPRACTICEFORSAMPLINGWORKPLACEATMOSPHERESTOCOLLECTGASESORVAPORSWITHSOLIDSORBENTDIFFUSIVESAMPLERS

链接地址:http://www.mydoc123.com/p-517466.html