《ASTM D4513-2011(2017) Standard Test Method for Particle Size Distribution of Catalytic Materials by Sieving《用筛分法测定催化材料粒度分布的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4513-2011(2017) Standard Test Method for Particle Size Distribution of Catalytic Materials by Sieving《用筛分法测定催化材料粒度分布的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4513 11 (Reapproved 2017)Standard Test Method forParticle Size Distribution of Catalytic Materials by Sieving1This standard is issued under the fixed designation D4513; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of particlesize distribution of catalytic powder material using
3、a sievinginstrument and is one of several found valuable for themeasurement of particle size. This test method is particularlysuitable for particles in the 20 to 420-m range.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.
4、2.1 ExceptionIn 5.2, mesh size is the standard unit ofmeasure.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica
5、-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E11 Specification for Woven Wire Test Sieve Cloth and TestSievesE161 Specification for Precision Electroformed SievesE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE456 Terminology Rel
6、ating to Quality and Statistics3. Summary of Test Method3.1 A 50 % relative humidity-equilibrated sample of knownweight is allowed to fractionate on a series of various sizesieves to allow the various particle sizes to be collected onsuccessively smaller sieve openings.3.2 The sample fraction collec
7、ted on each sieve of the seriesis weighed and its fractional part of the original sample isdetermined.4. Significance and Use4.1 This test method can be used to determine particle sizedistributions of catalysts and supports for materialsspecifications, manufacturing control, and research and devel-o
8、pment work.5. Apparatus5.1 Laboratory Sieving Instrument, automatic with timerpreferred.5.2 U.S. Standard Sieves, or equivalent, to include microme-tres (mesh) 425(40), 250(60), 177(80), 149(100), 105(140),74(200), 44(325) and electroformed 30 and 20 micrometres.Because of their superior uniformity
9、and resistance to distor-tion or damage during use, electroformed sieves, preferablywith square holes, are recommended. Sieves with diametersbetween 6 and 10 cm are suggested.5.3 Ultrasonic Cleaning Tank, 100 W.5.4 Transmitted Light Microscope, 300 magnification, withcalibrated scale eyepiece.5.5 He
10、at Gun Dryer, (hair dryer or equivalent).5.6 Analytical Balance, capable of weighing to 0.001 g.5.7 Sample Splitter, Chute Type, or Spinning Riffler, withspinning riffler preferred.6. Reagents6.1 Antistatic Coating, (record cleaning spray or equiva-lent.)6.2 Alcohol-Water SolutionOne part ethanol to
11、 nine partsdeionized or distilled water.7. Sampling7.1 The sample must be free-flowing and homogeneous. Ifparticle size segregation is apparent to either the eye or fromobservation under a microscope, remix and resample thematerial using the proper riffling procedure.7.2 Equilibrate the sample at 20
12、 to 25C (68 to 77F) in adesiccator with a humidity level of 50 %. A 24-h period isusually sufficient.1This test method is under the jurisdiction of ASTM Committee D32 onCatalysts and is the direct responsibility of Subcommittee D32.02 on Physical-Mechanical Properties.Current edition approved Feb. 1
13、, 2017. Published February 2017. Originallyapproved in 1985. Last previous edition approved in 2011 as D451311). DOI:10.1520/D4513-11R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
14、nformation, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardi
15、zation established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.18. Calibration and Standardization8.1 Prior to use, check all sieves for damage or impropercl
16、eaning. If woven-wire sieves are used rather than the pre-ferred electroformed sieves, it is especially important tocarefully inspect the wire surface for wear, misalignment, tears,creases, or separation along the edges.NOTE 1Specifications for wire cloth sieves are described in Specifi-cation E11 a
17、nd specifications for electroformed sieves are described inSpecification E161.9. Procedure9.1 Select appropriate sieves for the sample being analyzed,typically the 149, 105, 74, 44, and 20-m sieves.NOTE 2For optimum results, the estimated particle size should bedetermined by microscopic examination
18、at 100300X. Sieves may then beselected to cover the size range of the particles.9.2 Clean 44 and 20-m sieves prior to use in an ultrasonicbath using a 10 % ethanol, 90 % water mixture. Dry the sievesin a low temperature air jet (hair dryer or equivalent) and allowto equilibrate at room temperature f
19、or 30 min before obtainingthe tare weights.9.3 Tare each sieve and the fines collector pan, recordingeach weight to the nearest 0.001 g.9.4 After taring, moisten a sheet of tissue paper withantistatic spray and coat the inside wall surface of each sieveby rubbing with the coated tissue.9.5 Place the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD451320112017STANDARDTESTMETHODFORPARTICLESIZEDISTRIBUTIONOFCATALYTICMATERIALSBYSIEVING 筛分 测定 催化

链接地址:http://www.mydoc123.com/p-517259.html