《ASTM D4444-2008 Standard Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters《手持式水分仪的实验室标准和校准的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4444-2008 Standard Test Method for Laboratory Standardization and Calibration of Hand-Held Moisture Meters《手持式水分仪的实验室标准和校准的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4444 08Standard Test Method forLaboratory Standardization and Calibration of Hand-HeldMoisture Meters1This standard is issued under the fixed designation D 4444; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method applies to th
3、e measurement of moisturecontent (MC) of solid wood products, including those contain-ing additives (that is, chemicals or adhesives) for laboratorystandardization and calibration of hand-held moisture meters1.2 This test method makes no distinction between metermeasurement technologies for standard
4、ization and calibrationrequirements. Provision is made for test specimen size toaccommodate specific meters. Appendix X1 provides an ex-planatory discussion and history corresponding to the manda-tory sections. Fundamental measurement technologies aredescribed in Appendix X2 when available.1.2.1 Met
5、ers employing differing technologies may notprovide equivalent readings under the same conditions. Whenthis test method has been applied, it is assumed that thereferenced meter is acceptable unless otherwise specified.Meters shall be calibrated with respect to MC by directmeasurement as determined b
6、y Test Methods D 4442.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior
7、to use.2. Referenced Documents2.1 ASTM Standards:2D 1990 Practice for Establishing Allowable Properties forVisually-Graded Dimension Lumber from In-Grade Testsof Full-Size SpecimensD 2915 Practice for Evaluating Allowable Properties forGrades of Structural LumberD 4442 Test Methods for Direct Moistu
8、re Content Measure-ment of Wood and Wood-Base MaterialsD 4933 Guide for Moisture Conditioning of Wood andWood-Based MaterialsD 5536 Practice for Sampling Forest Trees for Determina-tion of Clear Wood PropertiesD 7438 Practice for Field Calibration and Application ofHand-Held Moisture Meters2.2 Other
9、 ASTM Sources:ASTM Standards on Precision and Bias for Various Appli-cations, 19923. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 conductance metersConductance meters are thosethat measure predominantly ionic conductance between pointsof applied voltage, usually direct current
10、. Direct-current con-ductance meters are commonly referred to as “resistance”meters. Most commercial conductance meters are high-inputimpedance (about 1012V), wide-range (104to 1012V) ohm-meters.3.1.2 dielectric metersDielectric meters transmit electro-magnetic wave energy into the wood to detect th
11、e influence ofmoisture in the wood on these waves as an estimate of MC.Wave energy is most often in the radiofrequency range;hand-held meters commonly are placed directly on the woodsurface.4. Significance and Use4.1 Hand-held meters provide a rapid means of samplingMC of wood-based materials during
12、 and after processing tomaintain quality assurance and compliance with standards.These measurements are influenced by actual MC, a number ofother wood variables, environmental conditions, geometry ofthe measuring probe circuitry, and design of the meter. Themaximum accuracy can only be obtained by a
13、n awareness of1This test method is under the jurisdiction of ASTM Committee D07 on Woodand is the direct responsibility of Subcommittee D07.01 on Fundamental TestMethods and Properties.Current edition approved April 1, 2008. Published May 2008. Originallyapproved in 1984. Last previous edition appro
14、ved in 2003 as D 4444 92 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International
15、, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the effect of each parameter on the meter output and correctionof readings as specified by this test method.4.1.1 This test method employs controlled conditions andstraight-grain, clear wood specimens to provide me
16、asurementsthat are reproducible in a laboratory. The controlled conditionsprevent moisture and temperature gradients in the test speci-men.4.1.2 In laboratory calibration, the reference direct moisturemeasurements (for example, Test Methods D 4442) shall bemade only in the area of direct measurement
17、 of the meter. Thisminimizes error associated with sampling of differing areas ofmeasurement between this test method and that of the reference(Test Methods D 4442).4.2 Most uses of hand-held moisture meters employ correla-tive (predictive) relationships between the meter reading andwood areas or vo
18、lumes that exceed that of the direct metermeasurement (for example, larger specimens, pieces of lumber,or lots). These correlative relationships are beyond the scope ofthis test method. (See Practice D 7438.)5. Standardization5.1 GeneralStandardization provides a measured relation-ship to a standard
19、 reference material that can be used to ensurethat a meter is operating properly. Standardization shall beperformed to establish the integrity of the meter and electrode.Standardization shall be done before calibration and use. Ifalternate electrodes can be used with a meter, standardizationshall be
20、 done for all electrode types and alternate assemblies.5.2 Standardization shall be based, where feasible, on thedirect measurement region of the meter as supplied by themeter manufacturer. If not supplied by the manufacturer, thearea of direct measurement shall be determined by test.5.2.1 If the ma
21、nufacturer recommends an area, a method, ora standard specimen for standardization that does not reflect theentire direct measurement area of the meter, this shall be notedas the manufacturer recommendation.5.2.2 The meter circuit and electrode shall be tested withexternal reference material to veri
22、fy the precision and bias inthe meter response range of anticipated use. The meter shall beevaluated over the range of environmental conditions recom-mended by the manufacturer. The sensitivity of this standard-ization procedure to temperature of the meter shall be part ofthe evaluation.5.2.2.1 The
23、sensitivity of the standardization reference ma-terial to the range of environmental conditions in 5.2.2 shall beevaluated.5.2.3 ReportThe report shall indicate (in the metermanual, on the meter or meter scale, or on the suppliedreference standard) the meter model, and the electrodes forwhich the st
24、andardization is valid. The sensitivity of the meter,the electrode assembly and the reference material, as evaluatedin 5.2.2.1, shall be reported.5.2.3.1 The manufacturers recommendation on frequencyof standardization shall be included in the report.6. Calibration6.1 GeneralCalibration of a meter an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44442008STANDARDTESTMETHODFORLABORATORYSTANDARDIZATIONANDCALIBRATIONOFHANDHELDMOISTUREMETERS 手持

链接地址:http://www.mydoc123.com/p-517078.html