《ASTM D4443-2007 Standard Test Method for Determining Residual Vinyl Chloride Monomer Content in PPB Range in Vinyl Chloride Homo- and Co-Polymers by Headspace Gas Chromatography《用预.pdf》由会员分享,可在线阅读,更多相关《ASTM D4443-2007 Standard Test Method for Determining Residual Vinyl Chloride Monomer Content in PPB Range in Vinyl Chloride Homo- and Co-Polymers by Headspace Gas Chromatography《用预.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4443 07Standard Test Method forDetermining Residual Vinyl Chloride Monomer Content inPPB Range in Vinyl Chloride Homo- and Co-Polymers byHeadspace Gas Chromatography1This standard is issued under the fixed designation D 4443; the number immediately following the designation indicates
2、the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method is suitable for determining t
3、he residualvinyl chloride monomer (RVM) content of homopolymer andcopolymers of vinyl chloride down to a level of ;5 ppb.1.2 This test method is applicable to any polymer form, suchas resin, compound, film, bottle wall, etc. that can be dissolvedin a suitable solvent.1.3 This standard does not purpo
4、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardstatements are given in Section
5、 9 and Note 13.NOTE 1This test method is similar to ISO 6401.2. Referenced Documents2.1 ISO Standard:ISO 6401 PlasticsHomopolymer and Copolymer Resinsof Vinyl ChlorideDetermination of Residual VinylChloride MonomerGas Chromatographic Method22.2 OSHA Standard:29 CFR 1919.1017 Vinyl Chloride33. Termin
6、ology3.1 Abbreviations:3.1.1 DMAcN,N-dimethylacetamide.3.1.2 VCMVinyl chloride monomer.4. Summary of Test Method4.1 Samples of vinyl chloride-containing polymers are dis-solved in a suitable solvent in a closed system.4.2 The polymer solution and headspace are equilibrated atan elevated temperature.
7、4.3 Aliquots of headspace gas are injected into a gaschromatograph and the vinyl chloride monomer is separated.The response of vinyl chloride monomer is determined by theuse of one of several suggested detectors.4.4 Calibration is accomplished using either (a) vinyl chlo-ride monomer in nitrogen gas
8、 standards, (b) standard solutionscontaining known amounts of vinyl chloride monomer, or (c) amethod of standard addition.5. Significance and Use5.1 Vinyl chloride-containing polymers are widely used topackage a variety of materials, including foods.5.2 Vinyl chloride monomer has been shown to be a
9、humancarcinogen. Threshold toxicity value has not been established.5.3 Plastic manufacturers, food packagers, governmentagencies, etc. have a need to know the residual vinyl chloridemonomer content of vinyl chloride-containing polymers.6. Interferences6.1 N,N- dimethylacetamide should be analyzed un
10、der iden-tical conditions to determine the absence of interferences at thevinyl chloride monomer gas chromatography (GC) retentiontime.6.2 Other solvents, monomers, or compounding aids maycause interference at the vinyl chloride monomer GC retentiontime.7. Apparatus7.1 Gas Chromatography, equipped w
11、ith either a flameionization detector (FID), a photo ionization detector (PID), ora Hall electroconductivity detector (HED), backflushing valve,and either automatic capability or manual sampling (Note 2)and ability to analyze the headspace vapors contained in asealed vial.NOTE 2If the analyses are t
12、o be performed manually (that is, bysyringe injection), then the following equipment will also be needed:(1) Constant-temperature bath or oven capable of maintaining atemperature of 90 6 1C.1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility o
13、f Subcommittee D20.70 on Analytical Methods.Current edition approved Nov. 1, 2007. Published November 2007. Originallyapproved in 1984. Last previous edition approved in 2002 as D 4443 95(2002).2Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036
14、, http:/www.ansi.org.3Available from Superintendent of Documents, US Government Printing Office,Washington, DC 20402.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.(2
15、) Gas-tight GC syringes for sampling and injection.(3) Sample bottles with fluoropolymer faces septa and caps (sizeoptional).(4) Gloves for handling hot syringes.7.2 Chromatographic Column, 3 % OV-101 on 80/1004,5mesh Chromosorb WHP4,5,18-in. (3.2-mm) outside diameterby 2 ft (0.6 m), stainless steel
16、 connected through18-in. “tee” to0.19 % picric acid on 80/100 mesh Carbopack C4,5,18-in.outside diameter by 8 ft (2.4 m), stainless steel.NOTE 3Any column packing that will resolve VCM from interfer-ences and elute VCM in a reasonable length of time (1 to 5 min) issatisfactory. For example, a 3-ft (
17、0.9-m) by18-in. (3.2-mm) outsidediameter column containing 0.19 % picric acid on 80/100 mesh Carbo-pack C can replace the recommended 3 % OV 101 column. Settingsrecommended in 11.3.1 may have to be modified to suit the packingmaterial being used.NOTE 4The VCM peak must be kept on scale to manually m
18、easurethe correct peak area or peak height. One method of achieving this withoutundue operator attention is to use a dual-channel recorder. One channel isset at a high sensitivity to obtain measurable small peaks for low-VCMsamples. The other channel is set at a lower sensitivity to keep the largerp
19、eaks from high-VCM samples on scale. Most instruments will calculatepeak height (or area) even if the peak goes off the scale on the recorder.7.3 Detector Output Filter/AmplifierThe extreme sensi-tivity of this test method is best realized when the detector(usually operated at the maximum sensitivit
20、y) output is (1)filtered to remove the high-frequency noise and (2) amplified togive a visible or measurable signal. The filter/amplifier isconnected in series between the detector and the recorder/computer.NOTE 5A Spectrum Scientific Model 1021A filter/amplifier5,6canfulfill these requirements. Oth
21、er filter/amplifiers may be available that aresuitable.7.4 Sample Headspace Vials, glass, 23 mL, withfluoropolymer-lined septa and aluminum caps.7.5 Vial Sealer.7.6 Analytical Balance, capable of weighing to 60.001 g.7.7 Statistical Programmable Calculator.NOTE 6A programmable calculator is not abso
22、lutely necessary, butcan save a considerable amount of time when large numbers of samplesare being analyzed.8. Reagents and Materials8.1 Vinyl Chloride Monomer (neat), pure, preferably insmall cylinder.8.2 Standard Cylinders, vinyl chloride monomer in nitrogenat 1 and 10 ppm by volume.8.3 Hydrogen C
23、ylinder, prepurified gas.8.4 Nitrogen, oxygen-free.NOTE 7Helium may replace nitrogen as the carrier gas.8.5 Air, breathing or water-pumped.8.6 N,N-Dimethylacetamide (DMAc), sparged with nitrogengas for up to a week at room temperature to remove chromato-graphic interferences.9. Hazards9.1 Safety Pre
24、cautions:9.1.1 Vinyl chloride monomer is a carcinogen and exposureby inhalation or dermal contact, or both, is to be avoided. Referto OSHA Standard 29 CFR 1919.1017 for regulated levels ofexposure. N,N-dimethylacetamide is a teratogen. The use of aproperly functioning hood and septum-sealed sample c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD44432007STANDARDTESTMETHODFORDETERMININGRESIDUALVINYLCHLORIDEMONOMERCONTENTINPPBRANGEINVINYLCHLORIDEHOMOANDCOPOLYMERSBYHEADSPACEGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-517074.html