ASTM D4291-2004(2009) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《用过的发动机油中痕量乙二醇的标准试验方法》.pdf
《ASTM D4291-2004(2009) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《用过的发动机油中痕量乙二醇的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4291-2004(2009) Standard Test Method for Trace Ethylene Glycol in Used Engine Oil《用过的发动机油中痕量乙二醇的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4291 04 (Reapproved 2009)Standard Test Method forTrace Ethylene Glycol in Used Engine Oil1This standard is issued under the fixed designation D 4291; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of ethyleneglycol as a contaminant in used engine oil. This test method isdesigned
3、 to quantitate ethylene glycol in the range from 5 to200 mass ppm.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the app
4、lica-bility of regulatory limitations prior to use.For specific warningstatements, see Section 6.NOTE 1A qualitative determination of glycol-base antifreeze is pro-vided in Test Methods D 2982. Procedure A is sensitive to about 100 ppm.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification
5、for Reagent WaterD 2982 Test Methods for Detecting Glycol-Base Antifreezein Used Lubricating OilsD 4057 Practice for Manual Sampling of Petroleum andPetroleum Products3. Summary of Test Method3.1 The sample of oil is extracted with water and theanalysis is performed on the water extract. A reproduci
6、blevolume of the extract is injected into a gas chromatographusing on-column injection and the eluting compounds aredetected by a flame ionization detector. The ethylene glycolpeak area is determined and compared with areas obtainedfrom the injection of freshly prepared known standards.4. Significan
7、ce and Use4.1 Leakage of aqueous engine coolant into the crank caseweakens the ability of the oil to lubricate. If ethylene glycol ispresent, it promotes varnish and deposit formation. This testmethod is designed for early detection to prevent coolant fromaccumulating and seriously damaging the engi
8、ne.5. Apparatus5.1 Gas ChromatographAny gas chromatographequipped with the following:5.1.1 Flame Ionization Detector, capable of operating con-tinuously at a temperature equivalent to the maximum columntemperature employed, and connected to the column so as toavoid any cold spots.5.1.2 Sample Inlet
9、System, providing for on-column injec-tion and capable of operating continuously at a temperatureequivalent to the maximum column temperature employed.5.2 RecorderRecording potentiometer with a full-scaleresponse time of2sorless may be used.5.3 Columns1.2-m (4-ft) by 6.4-mm (14-in.) copper tubepacke
10、d with 5 mass % Carbowax 20-M liquid phase on 30/60mesh Chromosorb T solid support. As an alternative, a fusedsilica capillary column, 15 m long with a 0.53mm ID and2.0micron film thickness of a bonded polyethylene glycol canbe used.5.4 IntegratorManual, mechanical, or electronic integra-tion is req
11、uired to determine the peak area. However, bestprecision and automated operation can be achieved withelectronic integration.5.5 CentrifugeRCF 600 minimum and centrifuge tubeswith stoppers.5.6 SyringeA microsyringe, 10 L is needed for sampleintroduction.5.7 Pasteur Pipets.5.8 Vials, 2 mL, with crimpe
12、d septum caps.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications a
13、re available.3Other grades may be used,1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.04.0L on Gas Chromatography Methods.Current edition approved April 15, 2009. Published July 2009. Originall
14、yapproved in 1983. Last previous edition approved in 2004 as D 4291 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe AST
15、M website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For Suggestions on the testing of reagents notlisted by the American Chemical Society, see Annual Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States
16、Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.provided it is first ascertained that the reagent is of sufficientlyhigh purity to permit it
17、s use without lessening the accuracy ofthe determination.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type II of Specification D 1193.6.3 Air and Hydrogen(WarningThe air supply may befrom a cylinder under high pressure. Hydr
18、ogen is an extremelyflammable gas under pressure.)6.4 Calibration MixturesA minimum of three mixtures ofwater and ethylene glycol are prepared to cover the range from5 to 200 mass ppm. Prepare one blend of approximately 2000mass ppm ethylene glycol in water to provide for accurateweighing; then, pre
19、pare dilutions of that solution.6.5 Carrier Gas, helium or nitrogen may be used with theflame ionization detector. (WarningHelium and nitrogen arecompressed gases under high pressure.)6.6 Ethylene Glycol, 99 mass % pure.6.7 n-Hexane, 99 mol % pure. (Warningn-Hexane isextremely flammable, harmful if
20、inhaled, may produce nervecell damage.)6.8 Liquid Phase and Solid Support, 5 mass % Carbowax20-M liquid phase on 30/60 mesh Chromosorb T solid support.6.9 Tubing, 6.4 mm (14 in.) in outside diameter, 1.2 m (4 ft)long of copper.6.10 Water, deionized or distilled.7. Preparation of Apparatus7.1 Packed
21、Column PreparationIf a packed column isused, prepare it using the following steps:7.1.1 Prepare the packing, 5 mass % Carbowax 20-M liquidphase on 30/60 mesh Chromosorb T solid support, by anysatisfactory method used in the practice of gas chromatogra-phy.NOTE 2Care should be taken in handling Chrom
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD429120042009STANDARDTESTMETHODFORTRACEETHYLENEGLYCOLINUSEDENGINEOIL 发动 机油 痕量 乙二醇 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-516726.html