ASTM D3767-2003 Standard Practice for Rubber-Measurement of Dimensions《橡胶的标准规程 尺寸测量》.pdf
《ASTM D3767-2003 Standard Practice for Rubber-Measurement of Dimensions《橡胶的标准规程 尺寸测量》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3767-2003 Standard Practice for Rubber-Measurement of Dimensions《橡胶的标准规程 尺寸测量》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3767 03Standard Practice forRubberMeasurement of Dimensions1This standard is issued under the fixed designation D 3767; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthes
2、es indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice is intended for use in determining thegeometrical dimensio
3、ns of rubber products and specimens forphysical tests. This practice describes procedures for determin-ing length, width, thickness, diameter, and circumference. Thispractice does not cover sampling of materials or products, orlocations where a sample is to be taken.1.2 The values stated in either a
4、cceptable metric units or inother units shall be regarded separately as a standard. Thevalues stated in each system may not be exact equivalents;therefore, each system must be used independently of the other,without combining values in any other way.1.3 This standard does not purport to address all
5、of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility or regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1415 Test Method for
6、 Rubber PropertyInternationalHardnessD 3183 Practice for RubberPreparation of Pieces for TestPurposes From Products3. Summary of Practice3.1 Specific procedures are outlined depending upon size,texture, and shape of the test specimens undergoing measure-ment.3.1.1 Procedure A encompasses linear dime
7、nsions up to 30mm using a flat-footed micrometer on flat sheets and testspecimens.3.1.2 Procedure A1 encompasses thickness dimensions upto 30 mm using a micrometer with contact members that aredomed surfaces. This procedure is employed on irregularlyshaped test specimens and compression set test spe
8、cimens.3.1.3 Procedure A2 encompasses thickness measurementsof flexible cellular test specimens up to 30 mm using amicrometer with large area flat contact members.3.1.4 Procedure B encompasses linear dimensions between30 and 100 mm using a vernier caliper.3.1.5 Procedure C encompasses linear dimensi
9、ons above100 mm using a tape or linear scale.3.1.6 Procedure D encompasses thickness measurements onsoft thin materials using a microscope.3.1.7 Procedure E encompasses circumference measure-ments by cone.4. Significance and Use4.1 Dimensional measurements specified in this practice aremade for one
10、of the following purposes: (1) to determineconformance with specification requirements regarding geo-metrical properties of whole units, such as the size of rubbergloves, or the diameter and circumference of rubber hose, (2)to determine conformance with specification requirementsregarding particular
11、 functional parts of units, such as thethickness of the soles of boots, or ( 3) to determine geometricalvalues that are necessary in the calculation of test results forphysical properties for which requirements are specified, suchas the thickness of a test specimen for tensile strength. Themethod to
12、 be used shall be as specified in the detail specifica-tion or appropriate test method.4.2 Pressure applied by measuring instruments has a signifi-cant effect on the observed thickness of soft flexible materials,and it is therefore necessary to specify the pressure imposed bythe foot of the instrume
13、nt on the test piece for accuratecomparative measurements of such materials.5. Test Specimens5.1 Test specimens shall consist of a product, in whole or inpart, for which the geometric dimensions are sought, asdescribed in a detail specification or test method. Material, as1This practice is under the
14、 jurisdiction of ASTM Committee D11 on Rubber andis the direct responsibility of Subcommittee D11.10 on Physical Testing.Current edition approved Dec. 1, 2003. Published January 2004. Originallyapproved in 1979. Last previous edition approved in 2001 as D 3767 01.2For referenced ASTM standards, visi
15、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-29
16、59, United States.referenced herein, shall be interpreted as the substance(s) ofwhich a product is comprised.6. Number of Measurements6.1 Unless otherwise specified in the detail specification ortest method, three measurements shall be made on each testspecimen or product and the median value taken.
17、7. Buffing7.1 If the test specimen has uneven surfaces, such as fabricimpression or corrugations, that may interfere with the test, forexample, on the tube or cover of hose, the material may bebuffed lightly so that the surface is smooth and of uniformthickness. Buffing shall be performed in accorda
18、nce with thesections on Buffing Techniques, Abrasive Wheels, and Abra-sive Flexible Bands in Practice D 3183.8. Conditioning8.1 Unless otherwise specified in the detail specifications ortest method, geometrical measurements shall be made afterconditioning test specimens for 24 h at 23 6 5C (73.4 6 9
19、F).If Procedure D (see Section 12) is used, the relative humidityof 50 6 5 % at 23 6 2C (73.4 6 3.6F) should be maintained.PROCEDURES9. Procedures A, A1, and A2 (Dimensions of 30 mm orLess)9.1 Procedure A:9.1.1 ScopeDimensions of length, width, thickness, anddiameters of test specimens less than 30
20、mm (1.2 in.) shall bemeasured with a micrometer instrument.9.1.2 ApparatusThe apparatus shall consist of the follow-ing parts (an example of suitable apparatus is shown in Fig. 1NoteProcedure: Lift the yoke to the raised position and place the specimen between the base plate and circular presser foo
21、t. Lower the presser foot and yoke untilthe rod is resting freely on the test specimen, but with the dial-gage stem still supported. Lock the clamp and then lower the yoke fully. Read the micrometer.FIG. 1 Example of a Suitable Measuring Apparatus for Procedure AD3767032and Fig. 2):9.1.2.1 Anvil, at
22、 least 35 mm (1.4 in.) in diameter, that isattached to a rigid base plate.(1) Flat Rigid Base Plate, at least 140 mm (5.5 in.) indiameter, that is attached to a rigid frame.(2) Solid Platform Base (see Fig. 2), granite, at least 5 by 5in. square and 1.75 in. in height. The top surface is ground flat
23、and perpendicular to the guide post and micrometer assembly,at the operating height, to a tolerance of 60.002 in.9.1.2.2 Micrometer (such as a dial or digital-electronic),capable of measuring dimensions to an accuracy within 1 % ofthe dimension being measured or 0.001 mm, whichever isgreater.9.1.2.3
24、 Rigid Rod:(1) terminating in its lower end in a flat circular foot 3 to 10mm (0.12 to 0.39 in.) in diameter (see Fig. 1). The rod designshall allow various masses to be attached in order to give theoperator the capability of varying the pressure exerted on thetest specimen, by the presser foot, fro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD37672003STANDARDPRACTICEFORRUBBERMEASUREMENTOFDIMENSIONS 橡胶 标准 规程 尺寸 测量 PDF

链接地址:http://www.mydoc123.com/p-515447.html