1、Designation: D 3354 04Standard Test Method forBlocking Load of Plastic Film by the Parallel Plate Method1This standard is issued under the fixed designation D 3354; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method yields quantitative information regard-ing the degree of blocking (unwanted adhesion) existingbetween laye
3、rs of plastic film. It is not intended to measuresusceptibility to blocking.1.2 By this procedure, the film-to-film adhesion, expressedas a blocking load in grams, will cause two layers of film withan area of contact of 100 cm2to separate. The test method islimited to a maximum load of 200 g.1.3 The
4、 values stated in SI units are to be regarded asstandard. The values given in brackets are for information only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate saf
5、ety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This test method is similar to ISO 11502 Method B, but is nottechnically equivalent.2. Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 883 Terminology
6、Relating to PlasticsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standard:ISO 11502 Determination of Blocking Resistance33. Terminology3.1 Definitions: For definitions of terms used in this testmethod, refer to Terminology D 883.4. Summary
7、of Test Method4.1 Two pieces of film, which are in contact with each other,are placed between two 100-mm 4-in. square blocks. Theends of the films that extend past the blocks are secured to therespective upper and lower block. The force required toovercome the adhesion (blocking force) between the t
8、wopieces of film or until they reach 1.9 cm of separation ismeasured in grams using a constant-rate-of-load or a constant-rate-of separation device.5. Significance and Use5.1 Blocking develops in film processing and storage whenlayers of smooth film are in intimate contact with nearlycomplete exclus
9、ion of air. Temperature, or pressure, or both,can induce or change the degree of adhesion of the surfaces.5.2 The procedure of this test method closely simulates theoperation of separating film in some end-use applications.6. Apparatus6.1 The parallel block faces shall be square and 100 6 0.1mm (on
10、each edge with a flat and slightly knurled or sand-blasted finish of root mean square 125). A means must beprovided to prevent the blocks from sliding when they are incontact during loading.6.2 Constant-Rate-of-Load Device4:6.2.1 An instrument with 100-cm24-in.2 blocks whichelectronically times a lo
11、ading rate of 90 grams per minute (61)(see Fig. 1). The force required to separate the blocks isdisplayed electronically.NOTE 2On some constant-rate-of load devices, the weight is added bymoving a weight axially along the beam with a precision-drive system.This may be accomplished using a stepper mo
12、tor with a digital steppingdrive with 60 cycles as its reference control. The load rate must be 90grams per minute.6.3 Constant-Rate-of-Separation Testing DeviceA testingmachine of the constant-rate-of crosshead-movement type andcomprising essentially the following:6.3.1 Fixed MemberA fixed or essen
13、tially stationarymember carrying one aluminum block 100 by 100 6 1mmwith appropriate rigid adapter for mounting in a universaltesting machine.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.19 on Film and Sheeting.Curr
14、ent edition approved Sept. 1, 2004. Published May 2006. Originallyapproved in 1974. Last previous edition approved in 1996 as D 3354 - 96.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
15、information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4The sole source of supply of the electro mechanical apparatus known to thecommittee at this time is Kayeness, Inc.,
16、 East Main St., Honeybrook, PA 19344. Ifyou are aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.1Copyright ASTM International,
17、100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.3.2 Movable MemberA movable member carrying asecond aluminum block 100 by 100 6 1 mm with rigidcoupling for mounting in a universal testing machine.6.3.3 Drive MechanismA drive mechanism for impartingto the movable
18、 member a uniform, controlled velocity withrespect to the stationary member. The speed of testing, 51mm/min, is the rate of separation of the two blocks whenrunning idle (under no load). This rate of separation shall bemaintained within 5 % of the no-load value when runningunder full-capacity load.6
19、.3.4 Load IndicatorA suitable load-indicating mecha-nism capable of showing the tensile load, the greater of 1 % ofthe indicated force or 5 grams, carried by the test specimenheld by the block.6.4 Accessory EquipmentMay include a 100 by 180-mmtemplate or die, double-faced pressure-sensitive tape.7.
20、Test Specimens7.1 Cut unseparated test specimens with a 100 by 180-mmtemplate with the longer length being in the machine direction.Due to variations in gage and blocking tendencies, it isdesirable to select several sample locations across the width ofthe film. Five specimens shall be tested. If the
21、 test specimensare taken from a roll, care should be taken that the roll is ingood condition. Best results are obtained when specimens aretaken at least 25 mm below the outer surface of film rolls.8. Conditioning8.1 ConditioningCondition the test specimens at 23 62C 73.4 6 3.6F and 50 6 5 % relative
22、 humidity for not lessthan 40 h prior to test in accordance with Procedure A ofPractice D 618, for those tests where conditioning is required.In cases of disagreement, the tolerances shall be 61C61.8F and 62 % relative humidity.8.2 Test ConditionsConduct tests in the standard labora-tory atmosphere
23、of 23 6 2C 73.4 6 3.6F and 50 6 5%relative humidity, unless otherwise specified in the applicableASTM material specification. In cases of disagreements, thetolerances shall be 61C 61.8F and 62 % relative humid-ity.Procedures9. Procedure AConstant-Rate-of-Load Device9.1 Place double-coated tape over
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD33542004STANDARDTESTMETHODFORBLOCKINGLOADOFPLASTICFILMBYTHEPARALLELPLATEMETHOD 平行 测量 塑料薄膜 粘附 负荷

链接地址:http://www.mydoc123.com/p-514643.html