ASTM C829-1981(2005) Standard Practices for Measurement of Liquidus Temperature of Glass by the Gradient Furnace Method《用梯度炉法测量玻璃的液化温度的规程》.pdf
《ASTM C829-1981(2005) Standard Practices for Measurement of Liquidus Temperature of Glass by the Gradient Furnace Method《用梯度炉法测量玻璃的液化温度的规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C829-1981(2005) Standard Practices for Measurement of Liquidus Temperature of Glass by the Gradient Furnace Method《用梯度炉法测量玻璃的液化温度的规程》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 829 81 (Reapproved 2005)Standard Practices forMeasurement of Liquidus Temperature of Glass by theGradient Furnace Method1This standard is issued under the fixed designation C 829; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These practices cover procedures for determining theliquidus temperature (Note 1) of a glass
3、(Note 1) by establish-ing the boundary temperature for the first crystalline com-pound, when the glass specimen is held at a specified tempera-ture gradient over its entire length for a period of timenecessary to obtain thermal equilibrium between the crystallineand glassy phases.NOTE 1These terms a
4、re defined in Definitions C 162.1.2 Two methods are included, differing in the type ofsample, apparatus, procedure for positioning the sample, andmeasurement of temperature gradient in the furnace. Bothmethods have comparable precision. Method B is preferred forvery fluid glasses because it minimize
5、s thermal and mechanicalmixing effects.1.2.1 Method A employs a trough-type platinum container(tray) in which finely screened glass particles are fused into athin lath configuration defined by the trough.1.2.2 Method B employs a perforated platinum tray onwhich larger screened particles are position
6、ed one per hole onthe plate and are therefore melted separately from each other.21.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and de
7、termine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3C 162 Terminology of Glass and Glass Products2.2 Other Document:NIST Certificate for Liquidus Temperature, SRM 77343. Significance and Use3.1 These practices are useful for determining the ma
8、ximumtemperature at which crystallization will form in a glass, and aminimum temperature at which a glass can be held, forextended periods of time, without crystal formation andgrowth.4. Apparatus4.1 The apparatus for determining the liquidus temperatureshall consist essentially of an electrically h
9、eated gradientfurnace, a device for controlling the furnace temperature,temperature measuring equipment, and other items listed.4.1.1 Furnace:4.1.1.1 Method AHorizontal temperature gradient, electri-cally heated furnace, tube type, as illustrated in Fig. 1, Fig. 2,and Fig. 3 and described in A1.1.4.
10、1.1.2 Method BAn alternative furnace detail employingpregrooved Al2O3cores and dual windings, as illustrated inFig. 4 and Fig. 5, and described in A1.2.4.1.1.3 Equivalent temperature gradient conditions may alsobe obtained with furnaces having multiple windings equippedwith separate power and contro
11、l, or a tapped winding shuntedwith suitable resistances. For high precision, temperaturegradients in excess of 10C/cm should be avoided.4.1.2 Furnace Temperature Control:4.1.2.1 Method AA suitable temperature controller shallbe provided to maintain a fixed axial temperature distributionover the leng
12、th of the furnace.4.1.2.2 Method BArheostat shall be used to supply powerto the outer winding.Aseparate rheostat and controller shall beused for the inner core winding. The basic furnace temperaturelevel is achieved by controlling power to both inner and outercore windings. The slope of the gradient
13、 is achieved byadjusting power input to the outer core winding only. Theestablished temperature gradient is then maintained by control-ling power to the inner core winding only.4.1.3 Temperature-Measuring Equipment Furnace tem-peratures shall be measured with calibrated Type R or S1These practices a
14、re under the jurisdiction of ASTM Committee C14 on Glassand Glass Products and are the direct responsibility of Subcommittee C14.04 onPhysical and Mechanical Properties.Current edition approved Sept. 1, 2005. Published November 2005. Originallyapproved in 1976. Last previous edition approved in 2000
15、 as C 829-81(2000).2From NBS Research Paper RP2096, Vol 44, May 1950, by O. H. Grauer andE. H. Hamilton, with modification and improvement by K. J. Gajewski, Ford MotorCo., Glass Research and Development Office (work unpublished).3For referenced ASTM standards, visit the ASTM website, www.astm.org,
16、orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 3460, Gaithersburg, MD 20899-34601Copyri
17、ght ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.thermocouples in conjunction with a calibrated potentiometer,or other comparable instrumentation, capable of measurementswithin 0.5C. In addition to control thermocouples, Method Arequires an
18、unshielded supported thermocouple for insertioninto the furnace chamber to determine temperature gradients,and Method B requires five thermocouples mounted in thespecimen support fixture as shown in Fig. 6. An alternativemethod is to attach (spot weld) the thermocouples to a fixedplatinum or platinu
19、m alloy plate which supports the tray orperforated plate. A solid-state digital thermometer capable ofthe measurement accuracy specified may be used for tempera-ture measurement.4.1.4 MicroscopeAmicroscope capable of resolution of atleast 5 m at 1003 is required. A petrographic microscope ispreferre
20、d for ease of crystal identification under polarized light.4.1.5 Additional Equipment for Method A:4.1.5.1 Laboratory stand to support thermocouple horizon-tally (see Fig. 7).4.1.5.2 Trough-type platinum boats (see Fig. 8 and AnnexA2).4.1.5.3 Reshaping die for trough-type boats (see Fig. 8).4.1.5.4
21、Stainless steel mortar and pestle. ( The stainless steelmust be magnetic.)NOTE 1See A1.1 for further description.1. Outer shell (stainless steel) 7. Outer protection tube2. End plate (Transite)48. Sil-O-Cel5insulation3. End plate (quartz) 9. Control thermocouple (platinum/rhodium)4. Stand 10. Heatin
22、g element wire5. Inner protection tube 11. Specimen tray6. Heating element tubeFIG. 1 Liquidus Furnace (Method A)Material: 26-gage stainless steelFIG. 2 Liquidus Furnace Shell (Method A)MillimetresNo. of TurnsA: 6 turns4.8-mm spacingB: 13 turns9.5-mm spacingC: 5 turns6.4-mm spacingD: 24 turns4.8-mm
23、spacingFIG. 3 Recommended Liquidus Furnace Winding (Method A)C 829 81 (2005)24.1.5.5 Sieve, U.S. Standard, No. 20 (850-m) with receiverpan.4.1.5.6 Small horseshoe magnet.4.1.5.7 Glass vials with covers.4.1.5.8 Graduated measuring rod.4.1.5.9 Stainless steel tongs.4.1.5.10 Other minor items as descri
24、bed in the text.4.1.6 Additional Equipment for Method B:4.1.6.1 Riding device for simultaneously holding and posi-tioning multiple thermocouples and a perforated platinum tray.This device is provided with leveling screws, a means forlateral adjustment, and a positive stop for precisely locating theb
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC82919812005STANDARDPRACTICESFORMEASUREMENTOFLIQUIDUSTEMPERATUREOFGLASSBYTHEGRADIENTFURNACEMETHOD

链接地址:http://www.mydoc123.com/p-508457.html