ASTM C202-1993(2013) Standard Test Method for Thermal Conductivity of Refractory Brick《耐火砖导热性的标准试验方法》.pdf
《ASTM C202-1993(2013) Standard Test Method for Thermal Conductivity of Refractory Brick《耐火砖导热性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C202-1993(2013) Standard Test Method for Thermal Conductivity of Refractory Brick《耐火砖导热性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C202 93 (Reapproved 2013)Standard Test Method forThermal Conductivity of Refractory Brick1This standard is issued under the fixed designation C202; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method supplements Test Method C201 andshall be used in conjunction with that test method to determinethe thermal cond
3、uctivity of refractory brick with the exceptionof insulating firebrick (use Test Method C182), and carbonrefractories. This test method is designed for refractorieshaving a conductivity factor of not more than 200 Btuin./hft2F (28.8 W/mK).1.2 UnitsThe values stated in inch-pound units are to beregar
4、ded as standard. The values given in parentheses aremathematical conversions to SI units that are provided forinformation only and are not considered standard.1.2.1 ExceptionCertain flow and weight measurementsare expressed in SI units only.1.3 This standard does not purport to address all of thesaf
5、ety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C155 Classification of Insulati
6、ng FirebrickC182 Test Method for Thermal Conductivity of InsulatingFirebrickC201 Test Method for Thermal Conductivity of RefractoriesE220 Test Method for Calibration of Thermocouples ByComparison Techniques3. Significance and Use3.1 The thermal conductivity of refractory brick is a prop-erty require
7、d for selecting their thermal transmission charac-teristics. Users select refractory brick to provide specifiedconditions of heat loss and cold face temperature, withoutexceeding the temperature limitation of the brick. This testmethod establishes placement of thermocouples and position-ing of test
8、specimens in the calorimeter.3.2 This procedure must be used with Test Method C201and requires a large thermal gradient and steady state condi-tions. The results are based upon a mean temperature.3.3 The data from this test method are suitable for specifi-cation acceptance, estimating heat loss and
9、surfacetemperature, and design of multi-layer refractory construction.3.4 The use of these data requires consideration of the actualapplication environment and conditions.4. Apparatus4.1 The apparatus shall consist of that described in TestMethod C201 with the addition of thermocouples, back-upinsul
10、ation, and refractory fiber paper as described in Sections 6and 7 of this test method.5. Test Specimens5.1 The test specimens shall be selected and prepared inaccordance with Test Method C201.6. Installation of Thermocouples in Test Specimen6.1 ThermocouplesCalibrated3thermocouples shall beembedded
11、in the test specimen at two points for measuringtemperature. Platinum-10 % rhodium/platinum thermocouplesshall be used. Wire of AWG Gage 28 (0.320 mm) shall be usedin making the thermocouples.6.2 Installation of Thermocouples The hot junction of thethermocouples shall be placed in the center of each
12、 9- by412-in. (228- by 114-mm) face and just below the surface of thetest specimen. Grooves to receive the wire shall be cut in each9- by 412-in. (228- by 114-mm) face of the brick to a depth of132 in. (0.8 mm) by means of an abrasive wheel 0.02 in. (0.5mm) in thickness. The layout for the grooves a
13、llows all of thecold junction ends of the wires to extend from one end of thebrick. A groove shall be cut in the center of each 9 by 412-in.(228- by 114-mm) face along the 412-in. (114-mm) dimensionand ending 1 in. (25.4 mm) from each edge. The path of each1This test method is under the jurisdiction
14、 of ASTM Committee C08 onRefractories and is the direct responsibility of Subcommittee C08.02 on ThermalProperties.Current edition approved Sept. 1, 2013. Published September 2013. Originallyapproved in 1945. Last previous edition approved in 2009 as C202 93 (2009)1.DOI: 10.1520/C0202-93R13.2For ref
15、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Method E220 specifies calibration procedures for thermocouples.Copyr
16、ight ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1groove is extended at an angle of 90 to one end of the brickby cutting grooves parallel to and 1.0 in. (25.4 mm) from theedge of the specimen. Before cementing4the thermocouplewires in place,
17、 measurements shall be taken to obtain, within60.01 in. (0.3 mm), the eventual distance between the centerlines of the thermocouple junctions. This shall be done bymeasuring the 212-in. (64-mm) dimension of the brick at thelocation for the hot junctions and deducting the distancebetween the center l
18、ine of each junction in its embeddedposition and the surface of the brick.7. Set-Up of Back-Up Insulation, Specimen, and SiliconCarbide Slab7.1 The calorimeter and inner and outer guards shall becovered with a 0.50-in. (12.7-mm) thick layer of Group 20insulating firebrick (see Classification C155) f
19、or the purpose ofobtaining a higher mean temperature in the test specimen thanwould result by placing the specimen directly over the calo-rimeter area. The back-up insulation shall be cut and ground soas to provide surfaces that are plane and do not vary fromparallel by more than 60.01 in (0.3 mm).
20、The sides of thepieces that are to be placed in contact shall be ground plane andat right angles to the horizontal faces. The joints between thepieces shall be tight without the use of any mortar.7.2 Two strips of refractory fiber paper 1312 by12 by 0.02in. (343 by 13 by 0.5 mm) shall be placed alon
21、g the 1312-in.(343 mm) dimension of the inner guard at the outside edges.Twelve strips of refractory fiber paper 2 by12 by 0.02 in. (51by 13 by 0.5 mm) shall be placed on the outer guard at intervalsin the pattern shown in Fig. 1. These strips serve as spacers toprevent contact between the test mate
22、rial and the calorimeterassembly. The back-up insulation shall then be placed on thecalorimeter assembly so as to provide a level and plane surface.Additional strips of refractory fiber paper of the same dimen-sions shall be placed in the same pattern upon the back-upinsulation. These strips serve a
23、s spacers to prevent contactbetween the fireclay brick and the back-up insulation. The testspecimen shall be placed centrally over the center of thecalorimeter section on its 9- by 412-in. (228- by 114-mm) face,the guard brick placed at the sides of the test specimen so as tocover completely the cal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC20219932013STANDARDTESTMETHODFORTHERMALCONDUCTIVITYOFREFRACTORYBRICK 耐火砖 导热性 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-465997.html