《ASTM C1719-2011 Standard Test Method for Installed Precast Concrete Tanks and Accessories by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前已安装预制混凝土罐和配件负气压(真空)测试的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM C1719-2011 Standard Test Method for Installed Precast Concrete Tanks and Accessories by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前已安装预制混凝土罐和配件负气压(真空)测试的标准试验.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1719 11Standard Test Method forInstalled Precast Concrete Tanks and Accessories by theNegative Air Pressure (Vacuum) Test Prior to Backfill1This standard is issued under the fixed designation C1719; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for testing precastconcrete tanks (and in
3、stalled accessories) used for on-sitewastewater treatment, grease interception, grit/oil separation,water storage, or other applications requiring watertight con-struction and installation. This test method uses partial vacuumto demonstrate the integrity of the installed materials and theconstructio
4、n processes.1.2 This test method is intended to be used to demonstratethe condition of the installed system (precast concrete tank andaccessories) prior to backfill.1.3 Testing of the system before backfill is necessary so asto preclude inadvertent structural overloading of the systemcomponents duri
5、ng the test.NOTE 1Vacuum test criteria presented in this test method are similarto those in general use. The test and criteria have been widely andsuccessfully used in testing manholes as specified in Test Method C1244.1.4 The values stated in inch-pound units are to be regardedas standard. The valu
6、es given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to esta
7、blish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C822 Terminology Relating to Concrete Pipe and RelatedProductsC1227 Specification for Precast Concrete Septic TanksC1244 Test Method for C
8、oncrete Sewer Manholes by theNegative Air Pressure (Vacuum) Test Prior to Backfill3. Terminology3.1 For definitions of terms relating to tanks, see Terminol-ogy C822.4. Summary of Test Method4.1 The tank shall be set in its installed position. Requiredaccessories and pipes shall be installed. All op
9、enings and pipesentering the tank shall be plugged. A vacuum shall be drawnand vacuum retention over a specified time period is used todetermine the acceptability of the tank and installed accesso-ries.5. Significance and Use5.1 This is not a routine test. The values recorded areapplicable only to t
10、he tank being tested and at the time oftesting. This test is intended only to demonstrate the sealingeffectiveness of the installed system. Structural design of thetank is defined or demonstrated within the scope of otherapplicable specifications and test methods, including Specifi-cation C1227.6. E
11、quipment Required6.1 A vacuum device is required and shall be capable ofreliably drawing the required vacuum. Suitable vacuum de-vices include vane- and venturi-type pumps, vehicle vacuumsystems, and high-performance shop-style vacuum cleaners.6.2 A vacuum measuring device is required and shall be a
12、vacuum gauge, mercury manometer, or water manometeraccurate to 0.1 in. (2.5 mm) Hg 1.4 in. (35 mm) H2O. If agauge is used, it shall be in current calibration to standardstraceable to NIST and shall have a range of no more than 10 in.(254 mm) Hg.6.3 Suitable pipes (or pipe stubs), pipe plugs, and pro
13、perblocking for same shall be used. If temporary stubs are used,they shall be of the same size and type of pipe as that to be usedin the final installation of the system, and shall be placed in thesame orientation as required by the final installation of thesystem.1This test method is under the juri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17192011STANDARDTESTMETHODFORINSTALLEDPRECASTCONCRETETANKSANDACCESSORIESBYTHENEGATIVEAIRPRESSUREVACUUMTESTPRIORTOBACKFILL

链接地址:http://www.mydoc123.com/p-465640.html