1、Designation: C 1394 03 (Reapproved 2008)Standard Guide forIn-Situ Structural Silicone Glazing Evaluation1This standard is issued under the fixed designation C 1394; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONSSG is popular because of its unique method of retaining glass or other panels in smooth exteriorwalls, interrupted only by
3、narrow sealant joints. The first four-sided SSG in commercial constructionis on the former corporate headquarters building of SHG Incorporated (formerly known as Smith,Hinchman unknown structuralsealant durability; and the level of understanding of the principles of SSG by glazers. This guideaddress
4、es these concerns by providing suggestions for in situ evaluations of completed installations ofany age.1. Scope1.1 It is recommended to periodically evaluate the existingcondition of structural sealant glazing (hereinafter called SSG)installations in situ to detect problems before they becomesevere
5、 or pervasive. Evaluation of existing SSG installationsare required by certain building codes and local ordinances.This guide provides a program to evaluate the existing condi-tions, lists typical conditions, which might be found, andsuggests times when such evaluations are appropriate. Thecommittee
6、 with jurisdiction over this standard is not aware ofany comparable standards published by any other organiza-tions.2. Referenced Documents2.1 ASTM Standards:2C 717 Terminology of Building Seals and SealantsC 1392 Guide for Evaluating Failure of Structural SealantGlazingC 1401 Guide for Structural S
7、ealant Glazing3. Terminology3.1 Definitions: The definitions of the following terms usedin this guide are found in Terminology C 717: structuralsealant; structural sealant glazing; two-sided structural sealantglazing; four-sided structural sealant glazing; fluid migration.3.2 Definitions of Terms Sp
8、ecific to This Standard:3.2.1 qualified personone with a recognized degree orprofessional registration and extensive knowledge and experi-ence in the field of structural sealant glazing, and who iscapable of design, analysis, evaluation, and specifications inthe subject.4. Significance and Use4.1 Gu
9、idelines are provided for the procedures to evaluateexisting SSG installations, including two- and four-sidedinstallations. Due to the unlimited range of materials that maybe used in a particular building, the information contained inthis guide is general in nature. For a discussion of new SSGinstal
10、lations, refer to Guide C 1401.4.2 Typical conditions are listed that might be discoveredduring, or suggest the need for, such evaluations. Guidelinesare also suggested for times to perform evaluations. Theseguidelines are also necessarily general. Professional judgmentof a qualified person should b
11、e used in determining theappropriate time to perform an evaluation on a particularbuilding.1This guide is under the jurisdiction ofASTM Committee C24 on Building Sealsand Sealants and is the direct responsibility of Subcommittee C24.10 on Specifi-cations, Guides and Practices.Current edition approve
12、d May 1, 2008. Published June 2008. Originallyapproved in 1998. Last previous edition approved in 2003 as C 139403.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to t
13、he standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 This guide should not be the only reference consultedwhen determining the scope of a proposed evaluation. Forexample, the local
14、 building code and the manufacturersproduct literature for the actual materials used (if known)should also be considered.4.4 This document is not a substitute for experience andjudgment in assessing the condition of the specialized types ofconstruction discussed.5. Reasons to Perform an Evaluation5.
15、1 There are numerous reasons that a building owner ormanager (hereinafter “owner”) may choose to evaluate an SSGsystem, whether discretionary or to comply with an ordinance.The recommended evaluation levels, as discussed in Section 7,are referenced for each situation. The findings from one levelof i
16、nvestigation may trigger the need for a more in-depthinvestigation. At a minimum, it is recommended that anexisting SSG installation be evaluated when triggered by anyof the following events:5.1.1 After a natural disaster, such as an earthquake or majorwind storm, or a man-made disaster such as a bo
17、mb blast,Level 2;5.1.2 After a recall or published concern over a specificproduct or system, Level 1;5.1.3 Upon a change of property ownership, Level 1;5.1.4 Before repeating a new design, Level 1;5.1.5 As dictated by government regulations, Level 1 or 2;or5.1.6 When distress is discovered (see Sect
18、ion 8), Level 2,or, if prevalent distress is found, Level 3.5.2 In addition to event-triggered evaluations, it is recom-mended that proactive owners also perform periodic evalua-tions at the following intervals: (Note that some of theseperiods may overlap. If distress is found during any evaluation,
19、then more frequent and more in-depth evaluations should beconsidered.)5.2.1 When convenient, such as in conjunction with occa-sional glass replacement, or when access is available, Level 1;5.2.2 Immediately after installation of a new system, Level2;5.2.3 Just before expiration of the warranty perio
20、d, Level 2;5.2.4 Between 1 and 2 years after substantial completion,Level 1;5.2.5 After 5 years, Level 1;5.2.6 After 10 years, Level 2;5.2.7 After 15 years, Level 1 (if Level 2 was performed asrecommended after 10 years); and5.2.8 After 20 years, and each successive 10 years, Level 2.6. Symptoms of
21、Problems With SSG6.1 Whether due to original construction mistakes or latentdefects, SSG installations sometimes exhibit distress. Thefollowing list summarizes conditions that may indicate poororiginal construction or a subsequent failure of the structuralsealant, and therefore require evaluation. T
22、his list may not beall-inconclusive.6.1.1 Glass breakage from an unknown causeThere arenumerous potential causes of spontaneous glass breakage; ifthe cause is unknown, then it should be investigated prior toglass replacement whether an SSG defect contributed to thefailure.6.1.2 Air or water infiltra
23、tionIf air or water migratesthrough or to the structural sealant joint, then it must also havelost its structural functionat least for part of its length.Symptoms of air or water leakage include:6.1.2.1 Visible accumulation of liquid water during orfollowing storms;6.1.2.2 Wet insulation;6.1.2.3 Org
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC139420032008STANDARDGUIDEFORINSITUSTRUCTURALSILICONEGLAZINGEVALUATION 评价 原始 构造 硅酮 门窗 玻璃 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-464463.html