ASTM C1321-2004 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems (IRCCS) in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)的安装和使用的标准实施规程》.pdf
《ASTM C1321-2004 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems (IRCCS) in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)的安装和使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1321-2004 Standard Practice for Installation and Use of Interior Radiation Control Coating Systems (IRCCS) in Building Construction《建筑物内部辐射控制涂层系统(IRCCS)的安装和使用的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1321 04Standard Practice forInstallation and Use of Interior Radiation Control CoatingSystems (IRCCS) in Building Construction1This standard is issued under the fixed designation C 1321; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice has been prepared for use by the designer,specifier, and applicator of I
3、RCCS (Interior Radiation ControlCoating Systems) for use in building construction. The scope islimited to recommendations related to the use and installationof IRCCS, including a surface(s) having a far-infrared emit-tance of 0.25 or less that is sprayed or painted.2Some examplesthat this practice i
4、s intended to address include: (1) lowemittance surfaces in vented building envelope cavities in-tended to retard radiant transfer across the vented airspace; (2)low emittance surfaces at interior building surfaces intended toretard radiant transfer to or from building inhabitants; and (3)low emitta
5、nce surfaces at interior building surfaces intended toreduce radiant transfer to or from heating or cooling systems.See Fig. 1 and Fig. 2 for typical applications.1.2 This practice covers the installation process from pre-installation inspection through post-installation. It does notcover the produc
6、tion of the Interior Radiation Control CoatingMaterials.1.3 This practice is not intended to replace the manufactur-ers installation instructions, but it shall be used in conjunctionwith such instructions. This practice is not intended to super-sede local, state, or federal codes.1.4 This practice a
7、ssumes that the installer possesses a goodworking knowledge of the application codes and regulations,safety practices, tools, equipment, and methods necessary forthe installation of Interior Coating Materials. It also assumesthat the installer understands the fundamentals of buildingconstruction tha
8、t affect the installation of an IRCCS.1.5 When the installation or use of Interior RadiationControl Coating Materials, accessories, and systems may posesafety or health problems, the manufacturer shall provide theuser appropriate current information regarding any knownproblems associated with the re
9、commended use of the compa-nys products and shall also recommend protective measures tobe employed in their safe utilization. The user shall establishappropriate safety and health practices and determine theapplicability of regulatory requirements prior to use.1.6 This standard does not purport to a
10、ddress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are contained in S
11、ections 5 and 7.2. Referenced Documents2.1 ASTM Standards:C 168 Terminology Relating to Thermal InsulationC 1371 Test Method for Determination of Emittance ofMaterials Near Room Temperature Using Portable Emis-someterE 84 Test Method for Surface Burning CharacteristicsBuilding MaterialsE 96 Test Met
12、hods for Water Vapor Transmission of Mate-rials2.2 NFPA Standards:3NFPA 54 National Fuel Gas CodeNFPA 211 Standard for Chimneys, Fireplaces and Vents2.3 Other Documents:CPSC Product Safety Fact Sheet No. 18 “The Home Elec-trical System”43. Terminology3.1 DefinitionsFor definitions of terms used in t
13、his prac-tice, refer to Terminology C 168.3.2 Definitions of Terms Specific to This Standard:3.2.1 applicatorthe person or persons who apply interiorreflective coating materials in buildings.3.2.2 conditioned spaceany space in a building that isserved by a heating or cooling system.3.2.3 Interior Ra
14、diation Control Coating Systems(IRCCS)a building construction consisting of a low emit-tance (0.25 or less) surface bounded by an open air space. An1This practice is under the jurisdiction of ASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.21 on Reflectiv
15、eInsulation.Current edition approved May 1, 2004. Published June 2004. Originallyapproved 1996. Last previous edition approved in 1998 as C 132198.2The as-manufactured emittance of Interior Radiation Control Coating product,as determined on a typical substrate, should be stated on the label (see 7.2
16、.1).3Available from National Fire Protection Association, Batterymarch Park,Quincy, MA 02269.4Available from U.S. Consumer Product Safety Commission, Washington, DC20207.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.IRCCS is used f
17、or the sole purpose of limiting heat transfer byradiation and is not specifically intended to reduce heat transferby convection or conduction.3.2.4 open air spacea vented building cavity (for ex-ample, a vented attic) or a large conditioned or unconditionedbuilding space.3.2.5 DiscussionA large buil
18、ding space is defined as onewhose minimum dimension exceeds two feet.3.2.6 ownerthe person, partnership, corporation, agency,or other entity who owns the building in which the IRCCS isto be applied whether such ownership is by virtue of deed,contract, or any other instrument for acquiring legal titl
19、e underthe laws of the state in which the building is located.4. Significance and Use4.1 This practice recognizes that effectiveness, safety, anddurability of an IRCCS depends not only on the quality of thematerials, but also on the proper installation.4.2 Improper installation of an IRCCS will redu
20、ce itsthermal effectiveness, cause fire risks and other unsafe condi-tions, and promote deterioration of the structure in which it isinstalled. Specific hazards that can result from improperinstallation include: heat buildup in recessed lighting fixtures,deterioration of failure of electrical wiring
21、 components, anddeterioration of wood structures and paint failure due tomoisture accumulation.4.3 This practice provides recommendations for the instal-lation of IRCCS materials in a safe and effective manner.Actual conditions in existing buildings will vary greatly.Insome cases additional care sho
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC13212004STANDARDPRACTICEFORINSTALLATIONANDUSEOFINTERIORRADIATIONCONTROLCOATINGSYSTEMSIRCCSINBUILDINGCONSTRUCTION

链接地址:http://www.mydoc123.com/p-464218.html