ASTM C1319-2001(2006) Standard Specification for Concrete Grid Paving Units《混凝土格子铺设装置的标准规范》.pdf
《ASTM C1319-2001(2006) Standard Specification for Concrete Grid Paving Units《混凝土格子铺设装置的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1319-2001(2006) Standard Specification for Concrete Grid Paving Units《混凝土格子铺设装置的标准规范》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1319 01 (Reapproved 2006)Standard Specification forConcrete Grid Paving Units1This standard is issued under the fixed designation C 1319; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the requirements for concretegrid paving units for vehicular trafficways, parking areas, soilstabilization,
3、and revetments. Maximum dimensions are 24long by 24 in. wide (610 by 610 mm), with a minimumnominal thickness of 318 in. (80 mm).NOTE 1When particular features are desired, such as weight classifi-cation, higher compressive strength, surface texture, finish, color, or otherspecial features, such pro
4、perties should be specified separately by thepurchaser. However, local sellers should be consulted as to availability ofunits having the desired features.1.2 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnotes(excluding those in table
5、s and figures) shall not be consideredas requirements of the standard.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:2C33 Specification for Concrete AggregatesC 140 Test Me
6、thods for Sampling and Testing ConcreteMasonry Units and Related UnitsC 150 Specification for Portland CementC 331 Specification for Lightweight Aggregates for Con-crete Masonry UnitsC 595 Specification for Blended Hydraulic CementsC 618 Specification for Coal Fly Ash and Raw or CalcinedNatural Pozz
7、olan for Use in ConcreteC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1157 Performance Specification for Hydraulic CementC 1209 Terminology of Concrete Masonry Units and Re-lated UnitsC 1232 Terminology of Masonry3. Terminology3.1 Terminology defined in
8、 Terminology C 1209 and Ter-minology C 1232 shall apply for this specification.4. Materials4.1 Cementitious MaterialsMaterials shall conform to thefollowing applicable ASTM specifications:4.1.1 Portland CementsSpecification C 150.4.1.2 Modified Portland CementPortland cement con-forming to Specifica
9、tion C 150, modified as follows:4.1.2.1 Calcium carbonate, with a minimum 85 % CaCO3content, shall be permitted to be interground with the cement,provided the requirements of Specification C 150 as modifiedare met: limitation on insoluble residue is 1.5 % and limitationon loss on ignition is 7 %.4.1
10、.3 Blended Hydraulic CementsSpecification C 595.4.1.4 Hydraulic CementSpecification C 1157.4.1.5 PozzolansSpecification C 618.4.1.6 Blast Furnace Slag CementsSpecification C 989.4.2 AggregatesAggregates shall conform to one of thefollowing ASTM specifications, except that grading require-ments shall
11、 not necessarily apply:4.2.1 Normal WeightSpecification C33.4.2.2 LightweightSpecification C 331.4.3 Other ConstituentsAir-entraining agents, coloringpigments, integral water repellents, and finely ground silica,shall be previously established as suitable for use in concretegrid paving units and sha
12、ll conform to applicable ASTMstandards, or they shall be shown by test or experiencesatisfactory to the specifier and not to be detrimental to thedurability of the concrete grid paving unit or any materialcustomarily used in grid paving construction.5. Physical Requirements5.1 At the time of deliver
13、y to the work site, the units shallconform to the physical requirements prescribed in Table 1.5.2 DurabilityDurability shall be demonstrated by provenfield performance satisfactory to the specifier that the gridpaver units have adequate durability for the intended use.1This specification is under th
14、e jurisdiction of ASTM Committee C15 onManufactured Masonry Units and is the direct responsibility of SubcommitteeC15.03 on Concrete Masonry Units and Related Units.Current edition approved Dec. 1, 2006. Published December 2006. Originallyapproved in 1995. Last previous edition approved in 2001 as C
15、 1319 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC131920012006STANDARDSPECIFICATIONFORCONCRETEGRIDPAVINGUNITS 混凝土 格子 铺设 装置 标准规范 PDF

链接地址:http://www.mydoc123.com/p-464208.html