ASTM C1253-1993(2005) Standard Test Method for Determining the Outgassing Potential of Sealant Backing《测定密封层背衬除气能力的标准试验方法》.pdf
《ASTM C1253-1993(2005) Standard Test Method for Determining the Outgassing Potential of Sealant Backing《测定密封层背衬除气能力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1253-1993(2005) Standard Test Method for Determining the Outgassing Potential of Sealant Backing《测定密封层背衬除气能力的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1253 93 (Reapproved 2005)Standard Test Method forDetermining the Outgassing Potential of Sealant Backing1This standard is issued under the fixed designation C 1253; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method provides a procedure for determiningthe outgassing potential of a sealant backing when it i
3、spunctured during or after installation, with the puncture occur-ring before the sealant cures.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any,
4、 associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:C 717 Terminology of Building Seals and Sealants2C 11
5、93 Guide for Use of Joint Sealants23. Terminology3.1 DefinitionsRefer to Terminology C 717 for the fol-lowing terms used in this test method: sealant, cure, sealantbacking, joint, substrate, non-sag sealant, tooling, and outgas-sing.4. Summary of Test Method4.1 A sample of sealant backing material i
6、s placed betweennonporous substrates in a compressed condition, simulating theplacing of sealant backing on a job site. The sealant backing isthen punctured at intervals along its exposed face. A sealant isapplied immediately after puncture, and it is tooled to make atypical butt joint as described
7、in Guide C 1193. After tooling,the specimen is placed in an air circulating oven at elevatedtemperature for 1 h and then removed. The specimen iscompressed 1212 % of its diameter and in the compressed statereturned to the oven. The specimen is removed after anotherhour in the oven and compressed ano
8、ther 1212 % and returnedto the oven, where it remains for another 2 h. The specimen isremoved from the oven, and the sealant is allowed to finishcuring at room temperature, while in the compressed condition.The sealant is then removed from the specimen, and the backface (the face against the sealant
9、 backing) is examined. Thesealant is slit in half along its length and the size of any voidsestimated.5. Significance and Use5.1 This test method is an indicator of a potential sealingproblem that could occur if a sealant backing is flawed inmanufacture or transportation to the job site, or abused d
10、uringthe installation. If flawed, some sealant backing materials, incombination with certain environmental conditions, can out-gas, generating voids in the applied sealant before the sealantcures, thereby potentially compromising the cured sealantsintended performance.5.2 Voids are also known to be
11、caused by other means andunder certain conditions such as air entrapment during sealantapplication, trapped air in the substrate releasing into theuncured sealant, incompatibility of the sealant with the sealantbacking or substrate, or inhospitable installation conditions inthe field. This test meth
12、od is limited to identifying theoutgassing potential of a punctured sealant backing by forma-tion of a void in the soft uncured sealant under conditions ofheat and compression.6. Apparatus6.1 Air Circulating Oven, capable of maintaining a tempera-ture of 122F (50C).6.2 Test Frame and Stylus, as desc
13、ribed in Annex A1.7. Test Specimens7.1 Sealant backing should be 307.8-mm (12-in.) long andof a width appropriate for use in 12.7-mm (12-in.) wide joints.The proper width will be as specified by the sealant backingmanufacturer.NOTE 1The test method is specifically for 12.7-mm (12-in.) widejoints and
14、 sealant backings used in such joints. The procedure is adapted1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.20 onGeneral Test Methods.Current edition approved Jan. 1, 2005. Published January 2005.
15、Originallyapproved in 1993. Last previous edition approved in 1998 as C 125393(1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary
16、page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.easily to either wider or narrower joints if all compression is consideredas a percent of the joint width.8. Conditioning8.1 Condition all sealant backing and se
17、alants at standardconditions for a minimum of 12 h prior to testing. Standardconditions for this procedure are 23 6 2C (73.4 6 3.6F) and50 6 5 % relative humidity.9. Procedure9.1 Prepare the test specimen by placing the sealant backingin the simulated joint apparatus (Fig. A1.1 and Fig. A1.2),which
18、has been adjusted to a 12.7-mm (12-in.) wide opening.Exercise care not to abuse or puncture the sealant backingduring installation.9.2 Use the stylus (Fig. A1.3) to form six 9.5-mm (38-in.)deep punctures starting 38-mm (112-in.) from the end, spaced25.4-mm (1-in.) apart, and centered on the width of
19、 the sealantbacking. The marks on the channel, used to form the joint, aidin locating the quick, even placement of the punctures.9.2.1 If the sealant backing has a tendency to slip down inthe joint during the puncturing, slip a temporary solid form(such as a length of wood) beneath the backing to ho
20、ld it inplace. Remove this when the puncturing is complete.9.2.2 Time is a critical factor, so make all six punctures in 1min or less.9.3 Apply sealant over the sealant backing from a typicalcaulking gun in a pushing motion so air is not trapped betweensealant and sealant backing. Tool the sealant t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC125319932005STANDARDTESTMETHODFORDETERMININGTHEOUTGASSINGPOTENTIALOFSEALANTBACKING 测定 密封 层背衬 能力

链接地址:http://www.mydoc123.com/p-463938.html