1、Designation: A 598/A 598M 02 (Reapproved 2007)Standard Test Method forMagnetic Properties of Magnetic Amplifier Cores1This standard is issued under the fixed designationA 598/A 598M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the mag-netic performance of fully processed cores for magne
3、ticamplifier-type applications.1.2 Tests may be conducted at excitation frequencies of 60,400, 1600 Hz, or higher frequencies.1.3 Permissible core sizes for this test method are limitedonly by the available power supplies and the range andsensitivity of the instrumentation.1.4 At specified values of
4、 full-wave sinusoidal-current ex-citation, Hmax, this test method provides procedures of deter-mining the corresponding value of maximum induction, Bmax.1.5 At specified values of half-wave sinusoidal-current ex-citation, this test method provides procedures for determiningthe residual induction, Br
5、.1.6 At increased specified values of half-wave sinusoidal-current excitation, this test method provides procedures fordetermining the dc reverse biasing magnetic field strength, H1,required to reset the induction in the core material past Brto avalue where the total induction change, DB1, becomes a
6、pproxi-mately one third of the induction change, 2 Bp. It also providesprocedures for determining the additional dc reset magneticfield strength, DH, which, combined with H1, is the valuerequired to reset the induction in the core material past Brto avalue where the total induction change, DB2, beco
7、mes approxi-mately two thirds of the induction change 2 Bp.1.7 This test method specifies procedures for determiningcore gain from the corresponding biasing and inductionchanges, DH and DB.1.8 This test method covers test procedures and require-ments for evaluation of finished cores which are to be
8、used inmagnetic-amplifier-type applications. It is not a test for basic-material magnetic properties.1.9 This test method shall be used in conjunction withPractice A 34/A 34.1.10 Explanations of symbols and abbreviated definitionsappear in the text of this test method. The official symbols anddefini
9、tions are listed in Terminology A 340.1.11 The values and equations stated in customary (cgs-emuand inch-pound) or SI units are to be regarded separately asstandard. Within this test method, SI units are shown inbrackets. The values stated in each system may not be exactequivalents; therefore, each
10、system shall be used independentlyof the other. Combining values from the two systems mayresult in nonconformance with this test method.1.12 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to e
11、stablish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A 34/A 34M Practice for Sampling and Procurement Test-ing of Magnetic MaterialsA 340 Terminology of Symbols and Definitions Relating to
12、Magnetic TestingA 596/A 596M Test Method for Direct-Current MagneticProperties of Materials Using the Ballistic Method andRing Specimens3. Terminology3.1 Definitions Below is a list of symbols and definitionsas used in this test method. The official list of symbols anddefinitions may be found in Ter
13、minology A 340. (See Table 1where indicated).3.2 Symbols:1This test method is under the jurisdiction of ASTM Committee A06 onMagnetic Properties and is the direct responsibility of SubcommitteeA06.01 on TestMethods.Current edition approved May 1, 2007. Published January 2008. Originallyapproved in 1
14、969. Last previous edition approved in 2002 as A 598/A 598M02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website
15、.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.A = cross-sectional area of test specimen corematerial, cm2m2.A1= ac ammeter for primary circuit, half-wave,average-responsive, A.A2= dc ammeter for H1biasing winding, A.A3= dc ammeter
16、 for H2biasing winding, A.A4= dc milliammeter for ac voltage calibrator, V.BmaxBr= change in test specimen induction, underhalf-wave sinusoidal-current excitationspecified for this measurement.Bm= maximum induction in a sine-current SCMac flux-current loop Gauss Tesla (Note 1).Bp= maximum value of i
17、nduction in the sine-current half-wave CM flux-current loop, forthe reset test Gauss Tesla (Note 1).Br= residual induction in an ac sine-current flux-current loop Gauss Tesla.DB = change in magnetic induction Gauss Tesla(Table 1).DB1= change in induction in the flux-current loopduring H1test Gauss T
18、esla (Table 1).DB2= change of induction in the flux current loopduring H2test Gauss Tesla (Table 1).CM = cyclic magnetization (see TerminologyA 340).D1and D2= solid state diodes or other rectifiers.D3to D6= silicon diodes.d = lamination thickness, cm m.Eavg= average value of voltage waveform, V.f =
19、frequency of test, Hz.G = core gain DB2 B1/H2,H1,GaussOeFTA/mG.Hc= coercive field strength in an SCM flux-current loop Oe A/m.Hmax= maximum magnetic field strength in a sine-current SCM ac flux-current loop, Oe A/m(Note 1).Hp= maximum value of the sine-current ac mag-netic field strength for the CM
20、reset tests, OeA/m (Note 1).H1= dc biasing (reset) magnetic field strength forthe H1test point, Oe A/m.H2= dc biasing (reset) magnetic field strength forthe H2test point, Oe A/m.DH = change in dc biasing (reset) magnetic fieldstrength, Oe A/m.N1= test winding primary, ac excitation winding,turns.N2=
21、 test winding primary, dc H1biasing winding,turns.N3= test winding primary, dc H2biasing winding,turns.N4= test winding secondary, DB pickup winding,turns.SCM = symmetrical cyclic magnetization (see Ter-minology A 340).NOTE 1Note that Hmaxand Bmax, as used in this test method, aremaximum points on t
22、he sine-current SCM or corresponding half-waveCM flux-current loops.Also, that Hpand Bpare maximum points on a CMflux-current loop corresponding to the ac half-wave sine current which isestablished in the exciting winding, N1, and held constant, during the dccurrent measurements for H1, H2,orDH. The
23、se definitions are differentfrom those used for the same symbols in Terminology A 340 for use withdc or sinusoidal-flux ac measurements.4. Summary of Test Method4.1 This test method uses the procedures commonly referredto as the “Constant Current Flux Reset Test Method”(C.C.F.R.). For graphic repres
24、entation of the magnetic ampli-fier core test see Appendix X3.4.2 Under its provision, a specific predetermined value ofsinusoidal-current excitation, Hmax,(Table 2) is established andthe corresponding induction change is measured to determinethe value of maximum induction which is then designatedBm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMA598A598M20022007STANDARDTESTMETHODFORMAGNETICPROPERTIESOFMAGNETICAMPLIFIERCORES 放大器 磁性 标准 试验 方法

链接地址:http://www.mydoc123.com/p-458891.html