《ASME TDP-1-2006 Recommended Practices for Prevention of Water Damage to Steam Turbines Used for Electric Power Generation Fossil-Fuel Plants《发电站用防水渍蒸汽涡轮机的推荐实施规程 矿物燃料设备》.pdf》由会员分享,可在线阅读,更多相关《ASME TDP-1-2006 Recommended Practices for Prevention of Water Damage to Steam Turbines Used for Electric Power Generation Fossil-Fuel Plants《发电站用防水渍蒸汽涡轮机的推荐实施规程 矿物燃料设备》.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、Recommended Practices for the Prevention of Water Damage to Steam Turbines Used for Electric Power GenerationFossil-Fueled PlantsAN AMERICAN NATIONAL STANDARDASME TDP-12006(Revision of ASME TDP-11998)Copyright ASME International Provided by IHS under license with ASME Not for ResaleNo reproduction o
2、r networking permitted without license from IHS-,-,-ASME TDP-12006(Revision of ASME TDP-11998)RecommendedPractices for thePrevention ofWater Damage toSteam Turbines Usedfor Electric PowerGenerationFossil-Fueled PlantsAN AMERICAN NATIONAL STANDARDThree Park Avenue New York, NY 10016Copyright ASME Int
3、ernational Provided by IHS under license with ASME Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-Date of Issuance: May 25, 2007The 2006 edition of this Standard is being issued with an automatic addenda subscription service.The use of addenda allows revisions mad
4、e in response to public review comments or committeeactions to be published as necessary. This Standard will be revised when the Society approves theissuance of a new edition.ASME issues written replies to inquiries concerning interpretations of technical aspects of thisStandard. The interpretations
5、 will be included with the above addenda service.ASME is the registered trademark of The American Society of Mechanical Engineers.This code or standard was developed under procedures accredited as meeting the criteria for American NationalStandards. The Standards Committee that approved the code or
6、standard was balanced to assure that individuals fromcompetent and concerned interests have had an opportunity to participate. The proposed code or standard was madeavailable for public review and comment that provides an opportunity for additional public input from industry, academia,regulatory age
7、ncies, and the public-at-large.ASME does not “approve,” “rate,” or “endorse” any item, construction, proprietary device, or activity.ASME does not take any position with respect to the validity of any patent rights asserted in connection with anyitems mentioned in this document, and does not underta
8、ke to insure anyone utilizing a standard against liability forinfringement of any applicable letters patent, nor assumes any such liability. Users of a code or standard are expresslyadvised that determination of the validity of any such patent rights, and the risk of infringement of such rights, ise
9、ntirely their own responsibility.Participation by federal agency representative(s) or person(s) affiliated with industry is not to be interpreted asgovernment or industry endorsement of this code or standard.ASME accepts responsibility for only those interpretations of this document issued in accord
10、ance with the establishedASME procedures and policies, which precludes the issuance of interpretations by individuals.No part of this document may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior written permission of the publisher.The American Society of Me
11、chanical EngineersThree Park Avenue, New York, NY 10016-5990Copyright 2007 byTHE AMERICAN SOCIETY OF MECHANICAL ENGINEERSAll rights reservedPrinted in U.S.A.Copyright ASME International Provided by IHS under license with ASME Not for ResaleNo reproduction or networking permitted without license from
12、 IHS-,-,-CONTENTSForeword ivCommittee Roster . v1 Scope 12 Criteria . 13 Design Recommendations . 44 Operating Recommendations. 275 Testing, Inspection, Maintenance, and Monitoring. 296 Conclusion 30Figures1 Typical Flash Tank/Separators Arrangement: Local Control System 62 Typical Flash Tank/Separa
13、tors Arrangement: Integrated Control System . 73 Typical Leveling System Arrangement: Integrated Control System . 84 Typical Attemperator System . 95 Typical Drain System With Redundant Level Elements 116 Typical Heater Steam Side Isolation System: Local Control System 147 Typical Heater Steam Side
14、Isolation System: Integrated Control System . 158 Typical Heater Tube Side Isolation System: Local Control System . 169 Typical Heater Tube Side Isolation System: Integrated Control System . 1710 Typical Deaerator Arrangement With Drain System: Local Control System . 2011 Typical Deaerator Arrangeme
15、nt With Drain System: Integrated Control System 2112 Typical Deaerator Arrangement With Inlet Isolation: Local Control System 2213 Typical Deaerator Arrangement With Inlet Isolation: Integrated Control System 2314 Main Turbine: Typical Steam Seal Arrangement . 27Tables1 Symbol Legend 52 Device Ident
16、ification Letters . 6iiiCopyright ASME International Provided by IHS under license with ASME Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-FOREWORDIn the late 1960s, a substantial increase in the number of reported occurrences of steam turbinedamage by water indu
17、ction precipitated design recommendations from the two major U.S. steamturbine manufacturers in an attempt to reduce such incidents. Consequently, utilities and designersbegan formulating their own design criteria because of the economic need to keep the generatingunits in service. Realizing the com
18、mon need for a uniform set of design criteria to alleviate thisproblem, an American Society of Mechanical Engineers (ASME) Standards Committee was formed,consisting of representatives of utilities, equipment manufacturers, and design consultants todevelop recommended practices for use in the electri
19、c generating industry.This Standard, resulting from the work and deliberation of the Turbine Water Damage Preven-tion Committee, was approved as a Standard of the American Society of Mechanical Engineersby the ASME Standardization Committee and the ASME Policy Board, Codes and Standards, onJuly 26,
20、1972.In 1979, the Committee proposed a revision to this ASME Standard to include information oncondenser steam and water dumps, direct contact feedwater heaters, and steam generators. Thisproposed revision was approved by the ASME Standardization Committee on April 25, 1980.The 1985 revision was app
21、roved as an American National Standard on September 13, 1985. In1994, the ASME Board on Standardization approved the disbandment of the Committee onTurbine Water Damage Prevention along with the withdrawal of the standard TDP-1. This wasdue to perceived lack of interest and use by the industry.Subse
22、quent interest from users and potential users for TDP-1 convinced ASME to reconstitutethe Committee under the Board on Pressure Technology Codes and Standards in June 1997. Asa result of this committees work, TDP-1-1985 was revised and approved as an American NationalStandard on June 17, 1998.The cu
23、rrent Standard is a revision of TDP-1-1998. This Standard has been reorganized toincorporate combined cycle, multiple steam generators, cycling, and cogeneration technologyand to incorporate the capabilities of modern plant instrumentation and control systems. ThisStandard is not intended to impose
24、new requirements retroactively for existing facilities. Thisrevision was approved as an American National Standard on November 6, 2006.ivCopyright ASME International Provided by IHS under license with ASME Not for ResaleNo reproduction or networking permitted without license from IHS-,-,-ASME TWDP C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASMETDP12006RECOMMENDEDPRACTICESFORPREVENTIONOFWATERDAMAGETOSTEAMTURBINESUSEDFORELECTRICPOWERGENERATIONFOSSILFUELPLANTS

链接地址:http://www.mydoc123.com/p-456993.html