ASD-STAN PREN 4839-003-2016 Aerospace series Arc Fault Circuit breakers three-pole temperature compensated rated current 3 A to 25 A 115 200 V a c 400 Hz constant frequency Part 00.pdf
《ASD-STAN PREN 4839-003-2016 Aerospace series Arc Fault Circuit breakers three-pole temperature compensated rated current 3 A to 25 A 115 200 V a c 400 Hz constant frequency Part 00.pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 4839-003-2016 Aerospace series Arc Fault Circuit breakers three-pole temperature compensated rated current 3 A to 25 A 115 200 V a c 400 Hz constant frequency Part 00.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM ASD-STAN prEN 4839-003 Edition P 1 December 2016 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Rue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.org ICS: Descriptors: ENG
2、LISH VERSION Aerospace series Arc Fault Circuit breakers, three-pole, temperature compensated, rated current 3 A to 25 A, 115/200 V a.c. 400 Hz constant frequency Part 003: Without auxiliary contacts Product standard Luft- und Raumfahrt Schutzschalter, lichtbogen (berschlags) sensitiv, dreipolig, Te
3、mperaturkompensiert, Nennstrme von 3 A bis 25 A, 115/200 V a.c. 400 Hz Konstantfrequenz Teil 003: Ohne Signalkontakt Produktnorm Srie arospatiale Disjoncteurs tripolaires dtection darc compenss en temprature, intensits nominales 3 A 25 A, 115/200 V a.c. 400 Hz frquence fixe Partie 003 : Sans contact
4、s auxiliaires Norme de produit This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically approved
5、 by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examination
6、and review by users and formal agreement of ASD-STAN, the ASD-STAN prEN will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at n
7、ational level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. ASD-STAN Technical Committee approves that: “This document is published by ASD-STAN for the needs of the European Aerospace Industry. The use of this standard is entire
8、ly voluntary, and its applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” ASD-STAN reviews each standard and technical report at least every five years at which time it may be revised, reaffirmed, stabili
9、zed or cancelled. ASD-STAN invites you to send your written comments or any suggestions that may arise. All rights reserved. No parts of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or o
10、therwise, without prior written permission of ASD-STAN. Order details: E-mail: salesasd-stan.org Web address: http:/www.asd-stan.org/ Edition approved for publication 1st December 2016 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 201
11、6 ASD-STAN prEN 4839-003:2016 (E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Terms and definitions . 3 4 Dimension and mass 4 5 Characteristics . 5 6 Designation. 10 7 Rated current code 10 8 Delivery codes . 10 9 Marking 11 10 Technical specification . 11 Foreword This standard
12、 was reviewed by the Domain Technical Coordinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 4839-003:2016 (E) 3 1 Scope This sta
13、ndard specifies the required characteristics for three-pole, arc fault circuit breakers, rated currents from 3 A to 25 A, switching capacity 65 In, for use in aircraft electrical systems. Their operating temperatures are between 40 C to 85 C at a maximum altitude of Z = 15 000 m. The thermal protect
14、ion is temperature compensated and operates between 55 C and 125 C. These arc fault circuit breakers are operated by a push-pull type single pushbutton (actuator), with delayed action “trip-free“ tripping. They will continue to function up to the short-circuit current. 2 Normative references The fol
15、lowing documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3841-100, A
16、erospace series Circuit breakers Test Methods Part 100: General EN 3841-305, Aerospace series Circuit breakers Test Methods Part 305: Short-circuit performance EN 4839-001, Aerospace series Arc fault circuit breakers, three-pole, temperature compensated, rated current from 3 A to 25 A, 115 V a.c. 40
17、0 Hz constant frequency Part 001: Technical specification EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware TR 6083, Aerospace series Cut-outs for installation of electrical components 1) FED-STD-595B, Colours used in Government Procurement 3 Terms and definitions For the
18、 purposes of this document, the terms and definitions given in EN 3841-100 apply. 1) Published as ASD-STAN Technical Report at the date of publication of this standard by Aerospace and Defense industries Association of European-Standardization (ASD-STAN) (www.asd-stan.org) prEN 4839-003:2016 (E) 4 4
19、 Dimension and mass 4.1 Dimensional characteristics The circuit breakers do not have to correspond to the pictorial illustration, only the dimensions given shall be adhered to. Dimensions are in millimetres. See Figure 1. Key 1 Push button released 7 Lockwasher 2 Black colour according to FED-STD-59
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN48390032016AEROSPACESERIESARCFAULTCIRCUITBREAKERSTHREEPOLETEMPERATURECOMPENSATEDRATEDCURRENT3ATO25A115200VAC400HZCONSTANTFREQUENCYPART00PDF

链接地址:http://www.mydoc123.com/p-453599.html