ASD-STAN PREN 2591-227-2014 Aerospace series Elements of electrical and optical connection Test methods Part 227 Partial discharges test (Edition P 1).pdf
《ASD-STAN PREN 2591-227-2014 Aerospace series Elements of electrical and optical connection Test methods Part 227 Partial discharges test (Edition P 1).pdf》由会员分享,可在线阅读,更多相关《ASD-STAN PREN 2591-227-2014 Aerospace series Elements of electrical and optical connection Test methods Part 227 Partial discharges test (Edition P 1).pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、ASD-STAN STANDARD NORME ASD-STAN ASD-STAN NORM prEN 2591-227 Edition P 1 March 2014 PUBLISHED BY THE AEROSPACE AND DEFENCE INDUSTRIES ASSOCIATION OF EUROPE - STANDARDIZATION Rue Montoyer 10 - 1000 Brussels - Tel. 32 2 775 8126 - Fax. 32 2 775 8131 - www.asd-stan.org ICS: 49.060 Descriptors: ENGLISH
2、VERSION Aerospace series Elements of electrical and optical connection Test methods Part 227: Partial discharges test Srie arospatiale Organes de connexion lectrique et optique Mthodes dessais Partie 227 : Essai de dcharges partielles Luft- und Raumfahrt Elektrische und optische Verbindungselemente
3、Prfverfahren Teil 227: Teilentladungsprfung This “Aerospace Series“ Prestandard has been drawn up under the responsibility of ASD-STAN (The AeroSpace and Defence Industries Association of Europe - Standardization). It is published for the needs of the European Aerospace Industry. It has been technic
4、ally approved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After
5、 examination and review by users and formal agreement of ASD-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at nat
6、ional level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Edition approved for publication 1st March 2014 Comments should be sent within six months after the date of publication to ASD-STAN Electrical Domain Copyright 2014 by AS
7、D-STAN prEN 2591-227:2014 (E) 2 Contents Page Foreword 2 1 Scope 3 2 Normative references 3 3 Abbreviations and definitions 4 4 Applicability 4 5 Apparatus . 4 6 Test methods . 5 7 Procedure . 9 8 Pass fail criteria . 9 9 Test report 10 Foreword This standard was reviewed by the Domain Technical Coo
8、rdinator of ASD-STANs Electrical Domain. After inquiries and votes carried out in accordance with the rules of ASD-STAN defined in ASD-STANs General Process Manual, this standard has received approval for Publication. prEN 2591-227:2014 (E) 3 Introduction For a connector, the presence of partial dis
9、charge effects at operating voltage may result in a significant reduction of service life. Evidence of partial discharges during operation signifies for example: Distance between contact cavities is insufficient for the applied voltage, The quality of the insulation is inadequate possibly due to exc
10、essive size of the cavities or voids inside the insulation, A leakage way is present, resulting in a local reduction of the connector insulation properties. The most significant parameters which may influence PDIV, are, when both low pressure and high temperature could be combined (engine area for e
11、xample). The aim of this standard is to define the test method and procedure which will determine if an electrical connector will be subjected to partial discharges; in particularly, when it is exposed to a specified temperature and pressure based on an Aircraft environment. 1 Scope This test standa
12、rd defines methods to measure the partial discharge inception/extinction voltages (PDIV, PDEV) and partial discharge levels under specific temperatures and pressures on an electrical connector for aircraft use. It shall be use together with EN 2591-100. 2 Normative references The following documents
13、, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 2267-012, Aerospace series
14、Cables, electrical, for general purpose Operating temperatures between 55 C and 260 C Part 012: DZ family, single UV laser printable for use in low pressure atmosphere Product standard 1) EN 2591-100, Aerospace series Elements of electrical and optical connection Test methods Part 100: General EN 31
15、55 (all parts), Aerospace series Electrical contacts used in elements of connection EN 60270, High-voltage test techniques Partial discharge measurements ASTM D 1868-07, Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems 2) 1)
16、Published as ASD-STAN Prestandard at the date of publication of this standard. http:/www.asd-stan.org/ 2) Published by: ASTM National (US) American Society for Testing and Materials http:/www.astm.org/ prEN 2591-227:2014 (E) 4 3 Abbreviations and definitions DUT Device Under Test PD Partial Discharg
17、es For the purpose of this document, the following abbreviations shall be used: PDIV Partial Discharge Inception Voltage PDEV Partial Discharge Extinction Voltage PDIV is the lowest voltage at which continuous partial discharges occur as the applied voltage is increased. PDEV is the highest voltage
18、at which partial discharges no longer occur as the applied voltage is decreased from the inception voltage described before. More precise information on the partial discharge phenomenon can be found in ASTM D 1868-07 or in EN 60270. One definition of partial discharge can be found in 3.1.2 of the AS
19、TM D 1868-07. Test specimen or DUT: It is a connector (plug or receptacle) compliant to a required definition and configuration. 4 Applicability This test method is suitable for all types of connector used in un-pressurized area. 5 Apparatus The detection equipment shall be capable of detecting part
20、ial discharges of five (5) picocoulombs (pC) or less. The detection equipment, cautions and measurement procedures shall be equivalent to those described in ASTM D 1868-07 or in EN 60270. The frequency of the test voltage shall be between 48 Hz and 62 Hz, unless otherwise specified by the technical
21、specification. The apparatus must be capable to generate a combination of low pressure and high temperature, refer to Figure 1. prEN 2591-227:2014 (E) 5 Key 1 Monitoring 2 Power supply & DP monitoring 3 High immunity cables 4 High voltage wires 5 Temperature 6 Pressure 7 DUT (Device Under Test) 8 Cl
22、imatic chamber 9 Vacuum pump Figure 1 Example of apparatus principle 6 Test methods All contacts shall be wired with a wire qualified for high voltage purpose (use of EN 2267-012 standard or similar is recommended). Measurements shall be performed between the contact inside the concerned cavity and
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASDSTANPREN25912272014AEROSPACESERIESELEMENTSOFELECTRICALANDOPTICALCONNECTIONTESTMETHODSPART227PARTIALDISCHARGESTESTEDITIONP1PDF

链接地址:http://www.mydoc123.com/p-451188.html