ARMY MIL-PRF-51191 G-2011 HEATER AIR ELECTRICAL FILTER UNIT M3.pdf
《ARMY MIL-PRF-51191 G-2011 HEATER AIR ELECTRICAL FILTER UNIT M3.pdf》由会员分享,可在线阅读,更多相关《ARMY MIL-PRF-51191 G-2011 HEATER AIR ELECTRICAL FILTER UNIT M3.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、INCH - POUNDDISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.MIL-PRF-51191G(EA)14 February 2011SUPERSEDINGMIL-PRF-51191F(EA)w/AMENDMENT 123 August 2010PERFORMANCE SPECIFICATIONHEATER,AIR,ELECTRICAL,FILTERUNIT,M3Reactivated for new design after 12 June 1997This specifi
2、cation is approved for use by the U.S. Army EdgewoodChemical Biological Center, Department of the Army, and is availablefor useby all Departments andAgencies of theDepartment ofDefense.1. SCOPE1.1 Scope. This specification covers electric air heaters that provide for heating air sup-pliedfromGas-Par
3、ticulate Filter Units(GPFUs) tomilitary personnel who wearNuclear-Biological-Chemical (NBC) protective masks during cold weather operations.Comments, suggestions, or questions on this document should be addressed to: U.S. Army EdgewoodChemicalBiologicalCenter, ATTN: RDCB-DEA-S, 5183BlackhawkRoad,Abe
4、rdeenProvingGround,MD 21010-5424oremailedtoAPGR-EcbcSpecsTeamconus.army.mil. Since contact informationcanchange, youmay want toverify the currency of thisaddressinformationusingthe ASSIST Online databaseat https:/assist.daps.dla.mil.AMSC N/A FSC 4240Provided by IHSNot for ResaleNo reproduction or ne
5、tworking permitted without license from IHS-,-,-MIL-PRF-51191G(EA)22. APPLICABLE DOCUMENTS2.1 General. The documents listed in this section are specified in sections 3 and 4 of thisspecification.Thissectiondoesnotincludedocumentscitedinothersectionsofthisspecifica-tionor recommendedfor additional in
6、formationor as examples. While every effort has beenmade to insure the completeness of this list, document users are cautioned that they mustmeet all specified requirements documents cited in sections 3 and 4 of this specification,whetherornottheyarelisted.2.2 Government documents.2.2.1 Specificatio
7、ns, standards, and handbooks. The following Government documentsform a part of this document to the extent specified herein. Unless otherwise specified, theissues are those cited in the solicitation or contract.DEPARTMENT OF DEFENSE STANDARDSMS27142 - Connector, Plug, Electric- Pin Contact,No. 12, 1
8、4, 16 AWG, WaterproofMS27144 - Connector, Plug, Electrical- Socket Contact,No. 14 and 16 AWG, WaterproofMIL - STD - 461 - Requirements for the Control of ElectromagneticInterference Characteristics of Subsystems and EquipmentMIL - STD - 810 - Environmental Engineering Considerations and LaboratoryTe
9、stsMIL-STD-1168 - Ammunition Lot Numbering and Ammunition Data Card(Copies of these documents are available online at https:/assist.daps.dla.mil/quicksearch orfromtheStandardizationDocumentOrderDesk,700RobbinsAvenue,Building4D,Philadel-phia, PA 19111-5094.)2.2.2 Other Government documents, drawings,
10、 and publications. The following otherGovernment documents, drawings, and publications form a part of this document to the ex-tent specified herein. Unless otherwise specified, the issues are those citedin thesolicitationor contract.Provided by IHSNot for ResaleNo reproduction or networking permitte
11、d without license from IHS-,-,-MIL-PRF-51191G(EA)3DRAWINGSU.S. ARMY EDGEWOOD CHEMICAL BIOLOGICAL CENTER5-19-1782 - Heater, Air, Electric, Filter Unit, M3(Copies are available from U.S. Army Edgewood Chemical Biological Center, ATTN:RDCB-DEA-D, 5183 Blackhawk Road, Aberdeen Proving Ground, MD 21010-5
12、424.)U.S.ARMYARMAMENT,RESEARCH,DEVELOPMENTANDENGINEERINGCENTER12910415 - Guard Assembly(Copies of thisdrawing maybe requestedonline atpica.drawing.requestconus.army.milor from U.S. Army Armament, Research, Development and Engineering Center, ATTN:RDAR-EIS-PE, Picatinny Arsenal, NJ 07806-5000.)2.3 No
13、n-Government publications. The following documents form a part of this docu-ment to the extent specified herein. Unless otherwise specified, the issues of these docu-ments are those cited in the solicitation or contract.AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)ASME B1.1 - Unified Inch Screw Th
14、readsASME B1.2 - Gages and Gaging for Unified Inch Screw ThreadsASME B1.3 - ScrewThreadGagingSystemsforAcceptability: InchandMetricScrewThreads(Copies are available online at http:/www.asme.org/Publications/ or ASME, P.O. Box2300, Fairfield, NJ 07007-2300.)2.4 Order of precedence. Unless otherwise n
15、oted hereinor inthe contract, inthe eventofa conflict between the text of this document and the references cited herein, the text of thisProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-51191G(EA)4document takes precedence. Nothing in this spe
16、cification, however, supersedes applicablelaws and regulations unless a specific exemption has been obtained.3. REQUIREMENTS3.1 First article. When specified (see 6.2), a sample shall be subjected to first article in-spection in accordance with 4.2.3.2 Interface requirements.3.2.1Maximumcriticaldime
17、nsions. Thesizeof theair heatershall notexceed thefollow-ing critical dimensions: The maximum length (distance between furthest inlet port locationandfurthestoutletportlocation)shall be nogreaterthan7.32inches. The distancebetweenthebottomofthemountingbracket(baseplate) andthe highestpoint onthe con
18、trollerhous-ing (excluding the control knob) shall be no greater than 5.95 inches when the center axis ofthe controller is oriented perpendicular to the mounting bracket. The controller shall not ex-ceed a “footprint” of 2.78 x 3.70 inches,whereby the2.78 inchesis parallelto thelongitudinalaxis of t
19、he heater to allow necessary clearance for hose connections. A“footprint” is definedas the maximum length and width of the controller in any plane parallel to the heater basewhen the controller is upright relative to the base plate.3.2.2 Compatibility with interfacing parts. In addition to the requi
20、rements in 3.2.1, thefollowing requirements shall be met to insure compatibility of the air heater with the vehicleand its Gas Particulate Filter Unit (GPFU) system. The degree of movement, orientationand number of the air inlet and outlet ports shall be equivalent to those on Drawing5-19-1782 in fo
21、rm, fit and function. Two threaded plugs, which are form, fit, and functionequivalent to those on Drawing 5-19-1782, shall be installed in the side inlet and outletports. Material selection of the plugs and heaters housing shall prevent galvanic corrosionbetween the plugs and the housing. (Additiona
22、l plugs may be required by solicitation or spe-cial packaging instruction.) Female screw threads in the inlet and outlet ports of the heaterand those in the heater for the attachment of the controller to the heater shall conform toASME B1.1 and be compatible in form, fit, and function to threads def
23、ined for the inlet andoutlet ports and inDetail B ofDrawing 5-19-1782, respectively. The cable connectors onthe air heater shall be interoperable and interchangable with those shown on Drawing5-19-1782 and in MS27142 and MS27144. The female and male connectors shall remainfirmly attached except when
24、 normal hand force is used to separate them. The hole size andpattern in the mounting bracket of the heater shall conform to Detail C of Drawing5-19-1782. The heater withcontroller shall have the capabilitytobe mountedin the guardassembly (part no. 12910415) without interference.3.2.3 Controllerfeat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF51191G2011HEATERAIRELECTRICALFILTERUNITM3PDF

链接地址:http://www.mydoc123.com/p-447423.html