1、 Comments, suggestions, or questions on this document should be addressed to U.S. Army Soldier Systems Center, Natick, MA 01760-5018 or emailed to Joseph.MackoulNatick.Army.Mil . Since contact information can change, you may want to verify the currency of this address information using the ASSIST On
2、line database at http:/assist.daps.dla.mil . AMSC N/A FSC 4520 INCH - POUND MIL-PRF-32197 25 April 2006 PERFORMANCE SPECIFICATION HEATER, SPACE - NON-POWERED, LIQUID FUEL, SMALL This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1.1 Scope. T
3、his specification covers the performance and acceptance requirements for a non-powered, liquid fuel burning, 12,000 BTU, radiant space heater for use in the Soldier Crew Tent (SCT) and other 4 or 5 man tents. 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are specified in
4、sections 3 and 4 of this specification. This section does not include documents cited in other sections of this specification or recommended for additional information or as examples. While every effort has been made to ensure the completeness of this list, document users are cautioned that they mus
5、t meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are listed. 2.2 Government documents. The following documents form a part of this specification to the extent specified herein. Unless otherwise specified, the issues of the documents are
6、 those listed in the issue of the Department of Defense Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation. (see 6.2). Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32197 2 STANDARDS DEPARTMENT
7、OF DEFENSE MIL-STD-810 - Environmental Test Methods and Engineering Guidelines (Copies of these documents are available online at http:/assist.daps.dla.mil or from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D, Philadelphia, PA 19111-5094) 3. REQUIREMENTS 3.1 First article
8、. When specified (see 6.2), a sample shall be subjected to a first article inspection in accordance with 4.2. 3.2 Conformance. When specified (see 6.2), a sample shall be subjected to conformance inspection in accordance with 4.3. 3.3 Operating requirements. Each heater shall satisfy the following u
9、ser-oriented requirements. 3.3.1 Operation. The heater shall operate safely with all specified fuels and under all specified conditions herein with no electrical power. There shall be no exposure of flame during any mode of operation. There shall be no pool of raw liquid fuel in the burner area duri
10、ng operation or in the case of accidental flame loss. 3.3.2 Ignition. The heaters shall not require any electrical power for ignition. Ignition shall be accomplished safely in ten minutes or less with the use of a match. If priming is required it shall be accomplished safely and cleanly with no fuel
11、 spillage. If a device is required to facilitate priming it shall be securely fastened to the heater during transport. 3.3.3 Monitoring. The heaters shall incorporate a sight glass or other means for viewing the entire combustion flame during operation. 3.3.4 Liquid fuel. The heaters shall be safely
12、 operated with all of the fuels listed in Table I. TABLE I. Compatible Fuels Ambient Temperature Range Military Symbol CONUS Above +25 F DF-2 Above +10 F DF-1 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32197 3 Above -60 F JP8, DFA 3.3.5
13、Fuel supply. The heater shall have an integral fuel tank with sufficient capacity to provide 5 hours of operation when operated at 12,000 BTU/hr output, or higher. The tank shall be shielded from heat. At no time during operation shall fuel temperature exceed 100 F in the tank. The tank shall have a
14、 2-1/4” diameter fill hole to allow refueling and emptying with the fuel spout (NSN 7240-00-177-6154) that goes with the standard military 5 gallon. A small vent to allow makeup air into the tank shall be located on the top of the tank. The vent shall be capable of being closed to prevent fuel spill
15、age during transport of the heater. The heater shall also have the capability to connect to and operate from an external fuel supply. The external fuel supply will be the standard military 5 gallon fuel can elevated 4 feet above the ground with a gravity feed adapter and hose line with a Parker Hann
16、ifin female hose coupler part number B20-5BP. 3.3.6 Fuel control. The heaters shall have a fuel control that maintains a constant flow rate to the burner from the fuel tank with 10 settings. The heater settings shall be visible from a vantage point of two feet in front of the heater when the heater
17、is in the operational configuration inside the SCT. The fuel control shall provide sufficient fuel flow to achieve the full range of required heat outputs corresponding to Table II utilizing no less than 60% of the full range of 10 settings. The settings shall be permanently labeled. The fuel contro
18、l shall control fuel flow to the burner to eliminate any possibility of an unsafe over fire condition. The fuel control shall regulate the firing rate in conjunction with the heater, such that, for over 60% of the full range of settings, smoke levels shall not exceed a # 4 on the Bacharach smoke sca
19、le. The fuel control shall be located so that the heater is adjustable during operation while wearing cold weather gloves NSN 8415-00-227-1220, and it shall be sufficiently isolated from high heat so that it may be adjusted during operation without posing a burn hazard to the operator. 3.3.6.1 Fuel
20、overflow. The heater shall incorporate a fuel overflow device. The device shall divert fuel from the burner to an overflow hose leading to outside the tent in the event of a failure in the fuel control. The hose shall have a minimum length of 3 feet. 3.3.7 On/Off Valve. An on/off valve shall be loca
21、ted in an easily accessible location and shall immediately stop fuel flow to the burner when turned to the off position. The on/off valve shall be located so that it can be manipulated while wearing cold weather gloves NSN 8415-00-227-1220 and it shall be sufficiently isolated from high heat so that
22、 it may be manipulated during operation without posing a burn hazard to the operator. 3.3.8 Fuel filtering. A means to eliminate foreign particles from obstructing fuel flow shall be included. The device shall be located within a protected area on the heater and shall be located to allow for 15 minu
23、te removal, cleaning and installation using only common hand tools without the need for supplemental sealers to prevent leaks. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-PRF-32197 4 3.3.9 Combustion efficiency. The heater shall have a combus
24、tion efficiency greater than 50% when operated 10,000 BTU/hr or higher. 3.3.10 Smoke readings. The smoke reading of the heater shall not be greater than a No. 4 on the Bacharach smoke scale when the heater is operated between 9,000 BTU/Hr and 12,000 BTU/Hr. 3.3.11 Heat output. The heater shall provi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYMILPRF321972006HEATERSPACENONPOWEREDLIQUIDFUELSMALL 空间 加热器 小型 液体燃料 驱动 PDF

链接地址:http://www.mydoc123.com/p-447116.html