ARMY A-A-52482 B-2010 SWITCH ROTARY STOPLIGHT VEHICULAR MECHANICALLY ACTUATED 28 VOLT DC [Replaced ARMY MS75064 REV C CANC NOTICE 1 ARMY MS75064 REV C ARMY MS75064 REV B]《车辆用28伏直流机.pdf
《ARMY A-A-52482 B-2010 SWITCH ROTARY STOPLIGHT VEHICULAR MECHANICALLY ACTUATED 28 VOLT DC [Replaced ARMY MS75064 REV C CANC NOTICE 1 ARMY MS75064 REV C ARMY MS75064 REV B]《车辆用28伏直流机.pdf》由会员分享,可在线阅读,更多相关《ARMY A-A-52482 B-2010 SWITCH ROTARY STOPLIGHT VEHICULAR MECHANICALLY ACTUATED 28 VOLT DC [Replaced ARMY MS75064 REV C CANC NOTICE 1 ARMY MS75064 REV C ARMY MS75064 REV B]《车辆用28伏直流机.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data that may improve this document should be sent to DAMI_STANDARDIZATIONconus.army.mil or U.S. Army RDECOM, Tank Automotive Research, Development and Engineering Center, ATTN: RDTA-EN/STND/TRANS MS #268, 6501
2、E. 11 Mile Road, Warren, MI 48397-5000. Since contact information can change, you may want to verify the currency of this address information using the ASSIST Online database at https:/assist.daps.dla.mil/online/. AMC N/A FSC 5930 INCH-POUND A-A-52482B April 14, 2010 SUPERSEDING A-A-52482A July 5, 1
3、995 COMMERCIAL ITEM DESCRIPTION SWITCH, ROTARY: STOPLIGHT, VEHICULAR, MECHANICALLY ACTUATED, 28 VOLT DC The General Services Administration has authorized the use of this commercial item description (CID) as a replacement for MS75064C(AT) for all federal agencies. 1. SCOPE. This CID covers a 28 volt
4、 (V) direct current (dc) single-pole, single-throw waterproof rotary switch intended for use with a stoplight in tactical vehicles operating on a nominal 24 Vdc electrical system. 2. SALIENT CHARACTERISTICS 2.1 Materials. Unless otherwise specified herein, materials used shall be in accordance with
5、the manufacturers drawings/specifications. The use of recovered material made in compliance with the regulatory requirements is acceptable providing that all requirements of this CID are met (see note d). 2.1.1 Dissimilar metals. Except where necessary to couple an electrical circuit, contact betwee
6、n dissimilar metals which would encourage galvanic action shall be avoided. 2.1.2 Plastic. The switch shall show no deteriorating effect during shipping, storage and usage, such as, cracking, chipping, or blistering. 2.1.3 Locking devices. Lockwashers, self-locking nuts, or other approved locking de
7、vices shall be incorporated where required to prevent loosening of components. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52482B 2 2.2 Design and configuration. Unless otherwise specified in figure 1, the design and configuration of the swit
8、ch shall be in accordance with the manufacturers drawings. Notes: 1. Dimensions are in inches, unless otherwise specified, tolerances are 1/32 on fractions, .005 on decimals, 2 on angles. Figure 1. Design and configuration. 2.3 Performance. The switch shall perform as specified here-in when energize
9、d at a rated load of 28 Vdc. 2.3.1 Voltage drop. The voltage drop between terminals shall be no greater than 150 millivolts when energized by a 28 Vdc source. 2.3.2 Overload. To determine the overload, the switch shall be energized by a 28 Vdc source and connected to loads 40 percent greater than ra
10、ted (lamp, resistive) loads. The switch shall be operated for 100 cycles at each specified load. For lamp loads, the load cycle shall be 1 0.1 second “on“ and 5 0.1 seconds “off“ (10 cycles per minute). After cycle is completed, the switch shall meet the requirements of 2.3.1. Provided by IHSNot for
11、 ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52482B 3 2.3.3 Endurance. The voltage drop shall be no greater than 500 millivolts after 50,000 cycles of operations during which the switch is energized by a 28 Vdc source and connected to the rated loads specified in 2
12、.3.2. The torque required to operate the switch shall be no less than 30 (max 70, see 2.3.5) ounce-inches. The switch shall show no evidence of malfunction during the test. 2.3.4 Dielectric strength. No burning, charring, loosening, arcing or other damage should be evidenced when applying a 1,000 V
13、root mean square (rms) voltage at a frequency of 60 cycles per second with the switch lever in each of its “on“ and “off“ positions. The applied voltage shall be increased from zero to the specified value at a rate of 400 V per second and shall be maintained between insulated terminals and ground fo
14、r one minute on each application. 2.3.5 Operating torque. The average of five measurements of the torque applied to move the switch for each direction of movement from each position should not be less than 30 nor more than 70 ounce-inches. 2.3.6 Maximum torque. With the lever turned to each extreme
15、position a torque load of 3 foot-pounds is applied to the switch. This load shall be applied gradually 5 times for each lever position and held for at least 10 seconds. No breakage, distortion or loosening of parts of the switch shall be evidenced. Subsequent to test, the switch shall meet the requi
16、rements of 2.3.1. 2.3.7 Terminal strength. The switch shall not evidence any damage, distortion or loosening of parts after applying for 10 seconds each a force of 25 pounds at the base of all terminals in four directions perpendicular to the longitude centerline of the terminals at 90E intervals, a
17、nd a 25 pounds pull along the terminal axes centerline. More so, 2.3.1 and 2.3.4 requirements shall be maintained. 2.3.8 Shock resistance. The switch shall evidence no mechanical or electrical malfunction (opening or closing of circuit) during and after exposure to 3 sawtooth shock pulses, each of 5
18、0 gravities (g) peak amplitude for 7 milliseconds (ms) duration, in both directions of each of the three orthogonal axes for a total of 18 shock pulses. One axis shall be through, or parallel to, the plane of contact movement and the lever when in “off“ position. The switch shall subsequently meet t
19、he requirements of 2.3.1 2.3.9 Vibration resistance. The switch shall evidence no electrical or mechanical malfunction when subjected to vibration for one hour along each of three mutually perpendicular axes, one of which shall be through or parallel to the switch shaft; the vibration shall be an ha
20、rmonic motion having an amplitude of 0.03 inch (0.06 inch total excursion) in a frequency sweep from 10 to 55 and return to 10 Hertz (Hz) in one minute. The switch shall subsequently meet the requirements of 2.3.1, 2.3.5 and 2.3.6. 2.4 Environmental conditions. Provided by IHSNot for ResaleNo reprod
21、uction or networking permitted without license from IHS-,-,-A-A-52482B 4 2.4.1 Salt spray resistance. The switch shall meet the requirements of 2.3.1 during and after exposure to a fog of atomized salt water of 5 percent salt solution for 200 hours at 95 +2/-3 degrees Fahrenheit (F). 2.4.2 Sand and
22、dust resistance. The switch shall meet the requirements of sc c.1 after exposure to sand and dust in an air velocity of 2500 500 feet per minute with humidity not exceeding 30% for 6 hours at 77F, and 6 hours at 160F. 2.4.3 Fungus resistance. The switch shall meet the requirements of 2.3.1, 2.3.2, 2
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52482B2010SWITCHROTARYSTOPLIGHTVEHICULARMECHANICALLYACTUATED28VOLTDCREPLACEDARMYMS75064REVCCANCNOTICE1ARMYMS75064REVCARMYMS75064REVB

链接地址:http://www.mydoc123.com/p-440013.html