1、Comments, suggestions, or questions on this document should be addressed to: U.S. ARMY TOPOGRAPHIC ENGINEERING CENTER, ATTN: CEERD-TS-T, 7701 TELEGRAPH ROAD, ALEXANDRIA, VA 22315-3864 or emailed to pd-tetec.army.mil . Since contact information can change, you may want to verify the currency of this
2、address information using the ASSIST Online database at www.dodssp.daps.mil . AMSC N/A FSC 6675 Distribution Statement A. Approved for public release; distribution is unlimited. A-A-52036B 28 June 2004 SUPERSEDING A-A-52036A 20 September 1999 COMMERCIAL ITEM DESCRIPTION LEVEL, SURVEYING, SELF-LEVELI
3、NG, AND TILTING The General Services Administration has authorized the use of this Commercial Item Description (CID) for all federal agencies. The original issue of this CID replaced MIL-L-52918. 1. SCOPE. 1.1 Abstract. This commercial item description covers levels (instruments) used for taking dif
4、ferential elevation measurements, in surveying and other engineering applications. The complete instrument shall consist of an internal focusing telescope capable of 360 degree rotation, image lens system, cross hairs (horizontal and vertical), leveling system, tripod, and accessories. 2. CLASSIFICA
5、TION. The levels shall be classified as follows: Type I Tilting level Style A With plane-parallel optical micrometer attachment Style B Without plane-parallel optical micrometer attachment Type II Self-leveling level Style A With horizontal circle graduations Style B Without horizontal circle gradua
6、tions Class 1 1st order accuracy Class 2 2nd order accuracy METRIC Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52036B 23. SALIENT CHARACTERISTICS. 3.1 Accuracy. Accuracy shall be certifiable, for the life of the level, to permit not greater t
7、han 1.54 seconds of error (1storder) for class 1 instruments; and not greater than 3.07 seconds of error (2ndorder) for class 2 instruments. 3.2 Level types. 3.2.1 Tilting level. A tilting instrument (type I) shall require manual leveling prior to use and periodic checking for maintenance of a level
8、 horizontal line of sight during use. The instrument shall be provided with a circular spirit level, or similar device, for initial coarse leveling and a graduated leveling readout device and leveling screws for precise leveling. The type I, style A level shall be equipped with a parallel-plane opti
9、cal micrometer that allows the operator to measure horizontal distances, within instrument limits. The type I, style B level shall not be equipped with an optical micrometer. 3.2.2 Self-leveling. A self-leveling instrument (type II) shall automatically maintain the telescope in a level position, unt
10、il no longer needed, once the instrument has been manually brought to a defined approximation of level. Type II instruments shall have provisions for measuring horizontal distances. The type II, style A instrument shall have provisions for horizontal full circle angle measurement; the style B instru
11、ment shall not. Type II levels shall be equipped with an automatic compensator, with a working range of not less than 15 seconds of arc, that shall maintain a true horizontal level line of sight at all telescope positions. After telescope rotation, the instrument shall return to true level in not gr
12、eater than 5 seconds. 3.3 Optical system. The optical system of either type instrument shall be aberration free, provide a clear, bright, high contrast, and sharp image throughout the focusing range and field of view. The image may be erect or inverted. Optical properties shall be as follows: a. Mag
13、nification: Not less than 30 diameters at an accuracy of 5 percent b. Objective lens effective aperture: Not less than 39 millimeters (mm) c. Minimum focus distance: Not greater than 3.7 meters d. Minimum field of view: Not less than 60 minutes of arc e. Resolution: Not less than 4 seconds of arc f.
14、 Eye relief distance: Not less than 7 mm 3.3.1 Reticle. The reticle shall be a pattern of permanent opaque lines, on a distortion free, optically transparent medium. It shall be adjustable for precise positioning of the cross hairs, in the horizontal and vertical planes, about the central line of si
15、ght axis of the telescope. The reticle shall be positioned in the eyepiece focus and so as to eliminate distortion during collimation. Horizontal and vertical stadia lines shall be a minimum of 5 minutes of arc in length, parallel to the corresponding cross lines, and spaced at standard stadia line
16、intervals of 1 to 100. The width of all reticle lines shall be 3 seconds of arc, + 0.0 seconds, -0.5 seconds. 3.3.2 Stadia constant. When horizontal distance is measured using the stadia method the difference shall not be greater than 0.3 percent when compared to the verified distance. 3.3.3 Optical
17、 micrometer. When provided, the parallel plate optical micrometer shall measure the interval between the horizontal reticle line and the nearest rod graduation directly to 1 mm. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52036B 33.4 Level in
18、dicators. 3.4.1 Coarse level indicator. The coarse leveling indicators shall be clearly visible when the instrument is set up, horizontal, and parallel to the line of sight. The level indicator sensitivity shall be by instrument type as follows: a. Type I 10 2 minutes of arc per 2 mm division. b. Ty
19、pe II 7 to 15 minutes of arc per 2 mm division. 3.4.2 Telescope (precise) level indicator. The type I telescope level indicator shall have a sensitivity of 8 to 10 seconds of arc, per 2 mm movement. Level indicator readings shall be clearly discernible in temperatures of -25 to +120F. 3.5 Mounting.
20、The instrument shall be mounted on a tribrach with a baseplate and leveling screws. Leveling screws shall operate without binding, backlash, or end play in temperatures of -25 to +120F. For interface with existing instruments, the tribrach shall have at its center a means of accepting an instrument
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA52036B2004LEVELSURVEYINGSELFLEVELINGANDTILTING 水准测量 自调 平和 倾斜 PDF

链接地址:http://www.mydoc123.com/p-439856.html