1、i A-A-52029 83 9999974 0063460 3 m - I INCH-POUND 1 9 May 1991 A-A-52029 COMMERCIAL ITEM DESCRIPTION CONTAINER, CARGO, . SIDE OPENING The General Services Administration has authorized the use of this commercial item description. This item description covers 20 foot, reusable, IS0 lCC, side opening,
2、 cargo containers for the transportation, distribution, and storage of military supplies. Salient characteristics Description. The containers shall be noncollapsible, of a permanent character and suitable for repeated use. inch IS0 1CC container with full length side opening doors. shall comply with
3、 the requirements of IS0 1496/1. The container shall be a steel 8 foot 6 The container Weiqht, ratinqs and dimensions. The tare weight of the container shall be the minimum practical but shall not exceed 6100 pounds. The gross weight rating shall be 52,910 pounds. Dimensions, tolerances, and diagona
4、l differences of the container shall meet the requirements for a 20 foot nominal length containers as specified in IS0 668. Standard Droduct. Except as otherwise specified herein, the container shall The container shall be new and be the standard product of the contractor. unused. Material. Material
5、 shall be as specified herein. Used, rebuilt or remanufactured components, pieces, and parts shall not be incorporated into the container. Materials not specified shall be in accordance with Federal, Military, or National Technical Society, Association or Institute specifications or standards. fabri
6、cated from compatible materials, inherently corrosion resistant or treated to provide protection against the various forms of corrosion and deterioration that may be encountered in any of the applicable operating or storage environments to which the container may be exposed. Material deterioration,
7、prevention and control. The container shall be Beneficial comments, recommendations, additions, deletions, clarifications, etc, and other data which may improve this document should be sent by letter to: Commander, US Army Belvoir Research, Development and Engineering Center, ATTN: STRBE-TSE, Fort B
8、el voi r, VA 22060-5606. AMSC N/A FSC 8115 DISTRIBUTION STATEMENT A. Approved for public release, distribution is unlimited. A Licensed by Information Handling ServicesProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-A-A-52029 81 9999974 00bL4b1 5 A-A
9、-52 02 9 Dissimilar metals. Dissimilar metals shall not be uced in inthte contact with each other unless protected against galvanic corrosion. specific material, material finish or treatmsnt for use with component or Cubcomponent, and shall make information available upon request to the contracting
10、officer or designated representative. recesses and voids in which contraband can be concealed or where moisture can accumulate. beyond the outside surfaces of the comer fittings. Identification of materials and finishes. .The contractor shall identify the Construction. The containers shall be constr
11、ucteii so as to be free of any No part of the container (when empty) shall protrude Doors. An unobstructed door opening with minimum dimensions of 84 inches high and 221 inches wide shall be provided. shall be hung within the side of the container to pravide access to the interior of the container.
12、The doors shall be hinged together to make two pairs. Heavy uty hhge pins, recessed within the corner post shall be provided on each door allowing the door pair to open a minimum of 170 degrees. corrosion resistant steel pins. than two heavy-duty, handle operated cam locking devices with anti-rack p
13、rovisions which through lever type action aid in releas- the door seal fram the door frame. accept- a padlock and security seal. doors in the full open position and shall be of a material which will not scrape or chafe the container when the doors are closed. The doors, when closed, shall be sealed
14、in such a manner as to prevent moisture entry into the container. hinges shall be permanently lubricated. The steel side walls and end walls may be of the interior or exterior post type, corrugated or of smooth skin construction. The end walls and side walls shall withstand loading in accordance wit
15、h IS0 1496/1 except each end wall shall withstand an internal loadkg equal to the full payload uniformiy distributed over the surface of the end wall. Four equally sized doors Each pair shall be hinged to a comer post. Steel hirges shall have Each door shall be provided with not less Fach locking de
16、vice handle must be capable of Means shall be provided to hold the All movixj parts of the door locking mechanism and door Side walls and enCi walls. Floor. The floor shall be fabricated of marhe grade harawood. The floor shall be attacheci to the crossmembers by countersunk fasteners, 1/4 inch mini
17、mum head diameter, either of the self-tapping screw type, or machine screws with self-locking nuts and shall be installed so that each head is O to 1/16 inch below the board surface and at least 1 inch frm the board edge. Screws shall be used on 10 inch centers on each cross member. The floor shall
18、be installed to permit lateral variations in floor board width due to swelling. be chdcally treated in accordance with the regulations as stated by the Vommonwealth of Australia Department of Health.Il affixed to the container indicating the immunization code used in the treat- proceCs. The floor sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ARMYAA520291991CONTAINERCARGOSIDEOPENING 开放 货物 集装箱 PDF

链接地址:http://www.mydoc123.com/p-439852.html