ANSI UL 60079-30-1-2017 UL Standard for Safety Explosive Atmospheres C Part 30-1 Electrical Resistance Trace Heating C General and Testing Requirements (First Edition).pdf
《ANSI UL 60079-30-1-2017 UL Standard for Safety Explosive Atmospheres C Part 30-1 Electrical Resistance Trace Heating C General and Testing Requirements (First Edition).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 60079-30-1-2017 UL Standard for Safety Explosive Atmospheres C Part 30-1 Electrical Resistance Trace Heating C General and Testing Requirements (First Edition).pdf(91页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 60079-30-1 Explosive Atmospheres Part 30-1: Electrical Resistance Trace Heating General and Testing Requirements STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
2、CTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Explosive Atmospheres Part 30-1: Electrical Resistance Trace Heating General and Testing Requirements, UL 60079-30-1 F
3、irst Edition, Dated May 5, 2017 Summary of Topics Adoption of IEC/IEEE 60079-30-1, Explosive Atmospheres - Part 30-1: Electrical Resistance Trace Heating General and Testing Requirements (rst edition, issued by IEC September 2015) as a new IEC/IEEE based UL standard, UL 60079-30-1 with US National D
4、ifferences. The requirements are substantially in accordance with Proposal(s) on this subject dated March 10, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recordin
5、g, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, cons
6、equential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs l
7、iability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (includin
8、g reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MAY 5, 2017 UL 60079-30-1 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL M
9、AY 5, 2017 UL 60079-30-1 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 5, 2017 1 UL 60079-30-1 Standard for Explosive Atmospheres Part 30-1: Electrical Resistance Trace Heating General and Testing Requirements F
10、irst Edition May 5, 2017 This ANSI/UL Standard for Safety consists of the First Edition. The most recent designation of ANSI/UL 60079-30-1 as an American National Standard (ANSI) occurred on May 5, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page.
11、 The National Difference Page and IEC Foreword are also excluded from the ANSI approval of IEC-based standards. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standa
12、rds Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive pr
13、operty of UL. COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 60079-30-1-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 5, 2017 UL 60079-30-1 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTIO
14、N OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface (UL) 6 National Differences 8 FOREWORD 9 INTRODUCTION . 14 1 Scope .15 2 Normative references .19 3 Terms and denitions 20 4 General requirements 27 4.1 General 27 4.2 Mechanical strength .28 4.3 Terminations and connections 28 4.4 Circui
15、t protection requirements for branch circuits .28 4.5 Temperature requirements 29 5 Testing .32 5.1 Type tests 32 5.2 Routine tests .60 6 Marking .60 6.1 Product markings for trace heaters 60 6.2 Markings for eld assembled components 61 7 Documentation requirements 61 7.1 General 61 7.2 Circuit desi
16、gn documentation .62 7.3 Trace heating system documentation 62 7.4 Instructions for installation of trace heating system 64 7.5 Instructions for commissioning 65 7.6 Instructions for maintenance / repair or modication .65 Annex A (informative) Type test matrix for EPLs Gb/Gc/Db/Dc (Refer to IEC 6007
17、9-14 for the relationship of EPLs to Zones) Annex B (informative) Checklist for installation Annex C (normative) Trace heater product design verication methodology C.1 General .68 C.2 Design methodology and selection of trace heaters 68 C.3 Stabilized design calculations .68 C.4 Trace heater perform
18、ance and equilibrium conditions 69 C.5 Heat loss calculations 72 C.6 Heat loss design safety factor .74 C.7 Maximum temperature determination .74 C.7.1 Theoretical pipe and sheath temperature calculations Metallic applications .74 C.7.2 Theoretical vessel and sheath temperature calculations Metallic
19、 applications .76 MAY 5, 2017 UL 60079-30-1 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL C.7.3 Sheath temperature metallic applications utilizing a temperature limiter control sensing the trace heater sheath or an articial hot spot 77 C.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL600793012017ULSTANDARDFORSAFETYEXPLOSIVEATMOSPHERESCPART301ELECTRICALRESISTANCETRACEHEATINGCGENERALANDTESTINGREQUIREMENTSFIRSTEDITIONPDF

链接地址:http://www.mydoc123.com/p-439327.html