ANSI UL 209-2011 UL Standard for Safety Cellular Metal Floor Raceways and Fittings (Tenth Edition Reprint with revisions through and including May 27 2016)《网状金属地面电缆管和管件安全标准》.pdf
《ANSI UL 209-2011 UL Standard for Safety Cellular Metal Floor Raceways and Fittings (Tenth Edition Reprint with revisions through and including May 27 2016)《网状金属地面电缆管和管件安全标准》.pdf》由会员分享,可在线阅读,更多相关《ANSI UL 209-2011 UL Standard for Safety Cellular Metal Floor Raceways and Fittings (Tenth Edition Reprint with revisions through and including May 27 2016)《网状金属地面电缆管和管件安全标准》.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 209 Cellular Metal Floor Raceways and Fittings STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MAT
2、ERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Cellular Metal Floor Raceways and Fittings, UL 209 Tenth Edition, Dated December 20, 2011 Summary of Topics The following revisions are being issued for the Tenth Edition of UL 209: 1.
3、 Revision to Installation Instructions (19.1) Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. The revised requirements are substantially in accordance with Proposal(s) on this subject dated April 1, 2016. All righ
4、ts reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either express
5、ed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising ou
6、t of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the elec
7、tronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Stand
8、ard on the purchasers computer system. MAY 27, 2016 UL 209 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 27, 2016 UL 209 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT
9、 PERMISSION FROM UL DECEMBER 20, 2011 (Title Page Reprinted: May 27, 2016) 1 UL 209 Standard for Cellular Metal Floor Raceways and Fittings First Edition December, 1956 Second Edition October, 1969 Third Edition July, 1973 Fourth Edition April, 1978 Fifth Edition November, 1981 Sixth Edition Februar
10、y, 1987 Seventh Edition November, 1995 Seventh Edition November, 1995 Eighth Edition December, 1998 Ninth Edition November, 2005 Tenth Edition December 20, 2011 This ANSI/UL Standard for Safety consists of the Tenth Edition including revisions through May 27, 2016. The most recent designation of ANS
11、I/UL 209 as an American National Standard (ANSI) occurred on May 27, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and Title Page. The Department of Defense (DoD) has adopted UL 209 on May 18, 1987. The publication of revised pages or a new edition of this Sta
12、ndard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety ar
13、e copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 2
14、09-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 20, 2011 CELLULAR METAL FLOOR RACEWAYS AND FITTINGS - UL 209 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMIS
15、SION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 General 4 2.1 Undated references .4 2.2 Units of measurement .4 CONSTRUCTION 3 General 5 4 Grounding and Bonding .6 5 Protective Coating 6 6 Cellular Metal Floor Raceways .7 7 Header Duct or Trench Header .9 8 Duct or Cell Fittings 10 9 Outlet Fittings
16、 .12 PERFORMANCE 10 Load Test 13 11 Tension/Shear Test 14 12 Peel Test .15 13 Grounding and Bonding Test .16 14 Protective Coating Test Zinc 16 15 Protective Coating Test Enamel .17 16 Rigidity of Cover Test 18 17 Flame Test .18 MARKINGS AND INSTRUCTIONS 18 Markings .21 19 Installation Accessories a
17、nd Instructions .22 EXAMINATION OF FINISHED PRODUCT BY MANUFACTURER 20 General 22 DECEMBER 20, 2011 CELLULAR METAL FLOOR RACEWAYS AND FITTINGS - UL 209 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requireme
18、nts cover cellular metal oor raceway systems intended to be installed as an integral part of the building structure and constructed for the installation of wires and cables in accordance with the National Electrical Code (NEC), NFPA 70. 1.2 These requirements do not cover rigid or exible conduit, su
19、rface metal raceways and ttings, underoor raceways and ttings, or other products of a similar nature. 1.3 These requirements do not cover the structural aspects or properties of cellular metal oor units their load-carrying and re-resistant capabilities or their physical dimensions with relation to m
20、echanical strength. 1.4 Cellular metal oor raceways consist of the hollow spaces in cellular metal oors and associated ttings that serve as enclosures for wires and cables. A duct or cell is a single enclosed tubular space in a cellular oor unit with a longitudinal axis parallel to the longitudinal
21、axis of the oor units. Header duct is an enclosed transverse wire raceway that, by providing access to predetermined cells of a cellular metal oor, facilitates the installation of wiring from a distribution center to the cells. Cellular metal oor raceway is always installed with concrete poured over
22、 the raceway and may be installed on top of a concrete slab. Trench header is a transverse wire raceway that provides access to all cells of the cellular oor units it crosses. Trench header allows lay-in wiring along its length by providing removable cover plates at its top surface. Trench header ma
23、y be the bottomless type allowing direct access for wiring into cells with factory punched holes or it may incorporate a bottom pan requiring eld cut entry holes into cells. 2 General 2.1 Undated references 2.1.1 Any undated reference to a code or standard appearing in the requirements of this stand
24、ard shall be interpreted as referring to the latest edition of that code or standard. 2.2 Units of measurement 2.2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or approximate information. 2.2.2 Unless otherwise indicated, all voltage and current valu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL2092011ULSTANDARDFORSAFETYCELLULARMETALFLOORRACEWAYSANDFITTINGSTENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMAY272016

链接地址:http://www.mydoc123.com/p-439039.html