1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 193 Alarm Valves for Fire-Protection Service STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATER
2、IAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Alarm Valves for Fire-Protection Service, UL 193 Eleventh Edition, Dated February 26, 2016 Summary of Topics This new edition of ANSI/UL 193 was issued to incorporate revisions to the Hy
3、drostatic Test Requirements in the Strength of Body Test and Bolt Strength, 10.13 and 28.1; and updates to the Pressure Gauge requirements in 26.2 and 29.1.8. The revised requirements are substantially in accordance with Proposal(s) on this subject dated November 6, 2015. All rights reserved. No par
4、t of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, incl
5、uding but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or
6、the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of
7、ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchase
8、rs computer system. FEBRUARY 26, 2016 UL 193 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 26, 2016 UL 193 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSI
9、ON FROM UL FEBRUARY 26, 2016 1 UL 193 Standard for Alarm Valves for Fire-Protection Service First Edition March, 1937 Second Edition June, 1952 Third Edition November, 1967 Fourth Edition November, 1972 Fifth Edition December, 1973 Sixth Edition April, 1979 Seventh Edition July, 1980 Eighth Edition
10、January, 1988 Ninth Edition March, 1993 Tenth Edition January, 2004 Eleventh Edition February 26, 2016 This ANSI/UL Standard for Safety consists of the Eleventh Edition. The most recent designation of ANSI/UL 193 as an American National Standard (ANSI) occurred on February 26, 2016. ANSI approval fo
11、r a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards
12、Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive propert
13、y of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 193-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL FEBRUARY 26, 2016 ALARM VALVES FOR FIRE-PROTECTION SERVICE - UL 193 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTH
14、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .5 3 Undated References 5 4 Components 5 5 Glossary .6 ASSEMBLY 6 General 6 7 Sizes 7 8 Working Pressures 7 9 Positions .7 10 Bodies and Covers .7 11 Valve Mechanisms .9
15、 11.1 General 9 11.2 Clapper supports 9 12 Clapper Stops 10 13 Clapper Rings and Seat Rings .10 14 Nonmetallic Materials .11 15 Clearances .11 16 Auxiliary Checks 12 17 Retarding Chambers 12 18 Valve Gags 13 PERFORMANCE 19 General 13 20 Metallic Materials Tests 13 21 Nonmetallic Materials Tests 14 2
16、1.1 General .14 21.2 Plastic parts .14 21.3 Elastomeric parts (except gaskets) .15 22 Adhesion Test for Resilient Seat Material 15 23 Installation Assembly Test .18 24 Servicing Test for Valves Without Handhole Openings 18 25 Positiveness of Response and Transmission Test 19 26 Hydraulic Friction Lo
17、ss Test 19 27 Leakage Test 20 28 Strength of Body Test .20 29 Operational Tests .20 29.1 Sensitiveness 20 29.2 Retarding factor 23 MANUFACTURING AND PRODUCTION TESTS 30 General 25 MARKING FEBRUARY 26, 2016 ALARM VALVES FOR FIRE-PROTECTION SERVICE - UL 193 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
18、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 31 General 25 INSTALLATION INSTRUCTIONS 32 Installation Instructions and Trim Drawings .26 FEBRUARY 26, 2016 ALARM VALVES FOR FIRE-PROTECTION SERVICE - UL 193 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUT
19、ION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover alarm valves for use in automatic wet-pipe sprinkler systems for re-protection service. Alarm valves covered by these requirements are of either the variable- or constant-pressure type and are of the swing-check pattern
20、. Ordinarily, variable-pressure alarm valves are acceptable for constant-pressure service without alteration; however, in some designs, that part of the device having to do with the delaying of alarms may be omitted. 1.2 Alarm valves covered by these requirements include the sizes11 2inches, inclusi
21、ve. 1.3 Alarm valves covered by these requirements are intended for installation and use in accordance with the Standard for the Installation of Sprinkler Systems, NFPA 13. 2 Units of Measurement 2.1 Values stated without parentheses are the requirement. Values in parentheses are explanatory or appr
22、oximate information. 3 Undated References 3.1 Any undated reference to a code or standard appearing in the requirements of this standard shall be interpreted as referring to the latest edition of that code or standard. 4 Components 4.1 Except as indicated in 4.2, a component of a product covered by
23、this standard shall comply with the requirements for that component. 4.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the application of the component in the product covered by this standard, or b) Is superseded by a re
24、quirement in this standard. 4.3 A component shall be used in accordance with its rating established for the intended conditions of use. 4.4 Specic components are incomplete in construction features or restricted in performance capabilities. Such components are intended for use only under limited con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL1932016ULSTANDARDFORSAFETYALARMVALVESFORFIREPROTECTIONSERVICEELEVENTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-439004.html