ANSI UL 1424-2015 UL Standard for Safety Cables for Power-Limited Fire-Alarm Circuits (Fourth Edition Reprint with revisions through and including December 8 2017).pdf
《ANSI UL 1424-2015 UL Standard for Safety Cables for Power-Limited Fire-Alarm Circuits (Fourth Edition Reprint with revisions through and including December 8 2017).pdf》由会员分享,可在线阅读,更多相关《ANSI UL 1424-2015 UL Standard for Safety Cables for Power-Limited Fire-Alarm Circuits (Fourth Edition Reprint with revisions through and including December 8 2017).pdf(76页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1424 Cables for Power-Limited Fire-Alarm CircuitsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORI
2、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Cables for Power-Limited Fire-Alarm Circuits, UL 1424 Fourth Edition, Dated January 22, 2015 Summary of Topics The Fourth Edition of the Standard for Safety for Cables for Power-Limited Fire-Alarm Circ
3、uits, UL 1424, has been issued to reect the reaffirmation of the ANSI approval. No changes in requirements have been made. The revisions are substantially in accordance with Proposal(s) on this subject dated December 5, 2014. All rights reserved. No part of this publication may be reproduced, stored
4、 in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warrantie
5、s of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL
6、or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indem
7、nify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this St
8、andard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are l
9、ocated after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 22, 2015 UL 1424 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 22, 2015 UL 1424 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORI
10、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 22, 2015 1 UL 1424 Standard for Cables for Power-Limited Fire-Alarm Circuits First Edition October, 1990 Second Edition April, 1996 Third Edition August, 2005 Fourth Edition January 22, 2015 This ANSI/UL Standard for Saf
11、ety consists of the Fourth Edition. The most recent designation of ANSI/UL 1424 as an American National Standard (ANSI) occurred on January 22, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for
12、revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standa
13、rd should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 1424-2010 (R2015)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REP
14、RODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 22, 2015 CABLES FOR POWER-LIMITED FIRE-ALARM CIRCUITS - UL 1424 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Me
15、asurement .7 3 References and Terms 7 CONSTRUCTION 4 Materials .7 5 Conductors .8 6 Metal Coating .10 7 Insulation .11 7.1 Material and application 11 7.2 Properties 11 7.3 Thicknesses 15 8 Coaxial and Optical-Fiber Members 22 9 Individual Covering .23 10 Electromagnetic Shield(s) 24 11 Binder(s) .2
16、5 12 Assembly of Multiple-Conductor Cable 25 13 Cable Jacket .27 14 Metal Covering .29 14.1 General .29 14.2 Smooth metal sheath .30 14.3 Welded and corrugated metal sheath .30 14.4 Extruded and corrugated metal sheath 31 14.5 Interlocked armor .32 15 Jacket over Metal Covering 33 PERFORMANCE 16 Con
17、tinuity Test of Conductors and Shields .33 17 D-C Resistance Test of Copper Conductors 34 18 Cold Bend Test of Insulation .38 19 Cold Bend Test of Complete Cable .40 20 Smoke and Fire Testing of Type FPLP Cable 41 21 Fire Testing of Type FPLR Cable .41 22 VW-1 (Vertical-Specimen) Flame Test .41 23 A
18、lternative Vertical-Tray Flame Tests on Type FPL Cable .42 23.1 General .42 23.2 UL test 42 23.3 FT4/IEEE 1202 Test 43 24 Sunlight Resistance Test 43 25 Spark Test after Insulating .43 26 Dielectric Voltage-Withstand Test .44 27 Test for Insulation Resistance at 60.0F (15.6C) .44 28 Long Term Insula
19、tion-Resistance Test in Water 48 29 Test Procedure for Determining the Multiplying-Factor Column for Adjusting Insulation Resistance .49 30 Shrinkback Test on Thermoplastic Insulation .51 JANUARY 22, 2015 CABLES FOR POWER-LIMITED FIRE-ALARM CIRCUITS - UL 1424 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED
20、FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 31 Crushing Resistance Test of Insulation 53 32 Crushing Test for Cable Marked for Direct Burial .54 33 Mechanical Water Absorption Test of Insulation in Direct-Burial Cable 55 34 Copper Sulphate Test of Zinc Coating on Steel Strip
21、for and from Interlocked Steel Armor . .56 35 Abrasion Resistance Test of Overall Jacket on Cable Consisting of a Single Coaxial Member .58 36 Tension Test of Interlocked Armor 61 37 Flexibility Test for Cable Having Interlocked Armor or a Smooth or Corrugated Metal Sheath .63 38 Circuit Integrity .
22、64 39 Durability Test of Ink Printing .65 40 Limited Combustible 66 41 Breaking Strength Test 66 MARKINGS 42 Intervals .66 43 Coding 66 44 Information on or in the Cable 67 45 Information on the Tag, Reel, or Carton .70 46 Multiple Markings .71 47 Date of Manufacture 72 JANUARY 22, 2015 CABLES FOR P
23、OWER-LIMITED FIRE-ALARM CIRCUITS - UL 1424 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover 60 250C (140 482F) single- and multiple-conductor cables for use as xed wiring within buildings (so
24、me are also marked for direct burial) principally for power-limited re-alarm circuits as described in Article 760 and other applicable parts of the National Electrical Code (NEC). Cables covered by these requirements are: a) Type FPLP (plenum cable), b) Type FPLR (riser cable), and c) Type FPL (cabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIUL14242015ULSTANDARDFORSAFETYCABLESFORPOWERLIMITEDFIREALARMCIRCUITSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGDECEMBER82017PDF

链接地址:http://www.mydoc123.com/p-438879.html