ANSI NEIS 409-2015 Standard for Installing and Maintaining Dry-Type Transformers.pdf
《ANSI NEIS 409-2015 Standard for Installing and Maintaining Dry-Type Transformers.pdf》由会员分享,可在线阅读,更多相关《ANSI NEIS 409-2015 Standard for Installing and Maintaining Dry-Type Transformers.pdf(45页珍藏版)》请在麦多课文档分享上搜索。
1、 AN AMERICAN NATIONAL STANDARD NECA 409-2015 Standard for Installing and Maintaining Dry-Type Transformers Published by National Electrical Contractors Association Published by National Electrical Contractors Association Standard for Installing and Maintaining Dry-Type Transformers NECA 409-2015 An
2、American National StandardNOTICE OF COPYRIGHT This document is copyrighted by NECA Reproduction of these documents either in hard copy or soft (including posting on the web) is prohibited without copyright permission. For copyright permission to reproduce portions of this document, please contact NE
3、CA Standards & Safety at (301) 215-4549, or send a fax to (301) 215-4500. OR National Electrical Contractors Association 3 Bethesda Metro Center, Suite 1100 Bethesda, Maryland 20814 (301) 657-3110 Revision History NECA 409-2002 originally published 04/2002 NECA 409-2009 revised 12/2009 NECA 409-2015
4、 revised 08/2015iii n 1. Scope Foreword v 1. Scope 1 1.1 Products and Applications Included .1 1.2 Products and Applications Excluded 1 1.3 Regulatory and Other Requirements 1 1.4 Mandatory Requirements, Permissive Requirements, Quality and Performance Recommendations, Explanatory Material, and Info
5、rmative Annexes.1 2. Definitions 3 3. Safety Procedures . 4 3.1 General 4 3.2 Safe Work Practices 4 3.3 Personal Protective Equipment (PPE) 5 3.4 De-Energizing Electrical Equipment 5 4. Receiving, Handling, and Storage . 6 4.1 Receiving .6 4.2 Handling .6 4.3 Storage .7 4.4 Pre-Installation Checks 7
6、 5. Installation 8 5.1 General 8 5.2 Environmental Conditions 8 5.3 Coordination with Other Trades .8 5.4 Supporting Transformers .9 5.5 General Installation Requirements 9 5.6 Disconnecting Means, Conductor Ampacity, and Overcurrent Protection10 5.7 Electrical Circuit Connections 10 5.8 Grounding a
7、nd Bonding 10 5.9 Transformer Accessories 11 6. Cleaning, Testing, and Commissioning . 12 6.2 Visual and Mechanical Inspection 12 6.3 Transformer Acceptance T esting13 6.4 Energizing Transformers 13 Table of Contentsn iv NECA 409 Standard for Installing and Maintaining Dry-Type Transformers 7. Site
8、Cleanup. 15 7.1 Restoring Transformer Finishes 15 7.2 Test Data and Manuals .15 7.3 Training .15 7.4 Spare Parts and Special Tools 15 8. Inspections and Maintenance 16 8.1 Frequency of Inspections and Maintenance .16 8.2 Routine Inspections .16 8.3 External Cleaning, Inspection, and Maintenance 17 8
9、.4 Internal Cleaning, Inspection, and Maintenance .18 8.5 Transformer Maintenance Testing.19 8.6 Re-energizing Transformers.19 8.7 Final Infrared Scan .19 9. Inspection and Re-energization After Adverse Operating Conditions 20 9.1 Inspection and Testing Following a Short-Circuit or Ground-Fault 20 9
10、.2 Transformers Soaked By or Submersed Under Water 20 9.3 Inspecting and Re-energizing Transformers Sprayed or Splashed with Clean Water 20 10. Drying Transformers . 21 10.1 General 21 10.2 Drying by Internal Heat .21 10.3 Drying by External Heat 21 10.4 Drying by Internal and External Heat 22 10.5
11、Determining Drying Time .22 11.1 General 23 11.2 Contact Resistance Test 23 11.3 Insulation Resistance Test 23 11.4 Turns Ratio Test 23 11.5 Excitation Current Test 24 11.6 Winding Resistance Test.24 11.7 Core Insulation Resistance Test .24 11.8 High Potential Test .24 11.9 Infrared Scan 25 11.10 In
12、sulation Power Factor Test 25 Annex A: Transformer Troubleshooting Guide . 26 Annex B: Recommended Tightening Torque Tables 32 Annex C: Reference Standards 35v n 1. Scope National Electrical Installation Standards (NEIS) are designed to improve communication among specifiers, purchasers, and supplie
13、rs of electrical construction services. They define a minimum baseline of quality and workmanship for installing electrical products and systems. NEIS are intended to be referenced in contract documents for electrical construction projects. The following language is recommended: Dry-type transformer
14、s should be installed and maintained in accordance with NECA 409-2015, Standard for Installing and Maintaining Dry- Type Transformers (ANSI). Use of NEIS is voluntary, and the National Electrical Contractors Association assumes no obligation or liability to users of this publication. Existence of a
15、standard shall not preclude any member or non- member of NECA from specifying or using alternate construction methods permitted by applicable regulations. This publication is intended to comply with the edition of the National Electrical Code (NEC) in effect at the time of publication. Because they
16、are quality standards, NEIS may in some instances go beyond the minimum safety requirements of the NEC. It is the responsibility of users of this publication to comply with applicable federal, state, and local electrical codes when installing electrical products and systems. Installers should also f
17、ollow all manufacturers installation instructions and ensure conformity to electrical ratings marked on such equipment. Suggestions for revisions and improvements to this standard are welcome. They should be addressed to: NECA Standards & Safety 3 Bethesda Metro Center, Suite 1100 Bethesda, MD 20814
18、 (301) 215-4549 (301) 215-4500 Fax www.neca-neis.org neisnecanet.org To purchase National Electrical Installation Standards, contact the NECA Order Desk at (301) 215-4504 tel, (301) 215-4500 fax or orderdesk necanet.org. NEIS can also be purchased in .pdf download format at www.neca-neis.org/standar
19、ds. Copyright 2015, National Electrical Contractors Association. All rights reserved. Unauthorized reproduction prohibited. National Electrical Installation Standards, NEIS, and the NEIS logo are trademarks of the National Electrical Contractors Association. National Electrical Code and NEC are regi
20、stered trademarks of the National Fire Protection Association, Quincy, MA. Foreword (This foreword is not a part of the standard)1 n 1. Scope 1.1 Products and Applications Included This standard describes the installation and maintenance procedures for single- and three- phase general purpose dry-ty
21、pe transformers and associated accessories rated 1000 Volts AC or less, and 0.25 kVA or more. This publication applies to indoor and outdoor, ventilated and non-ventilated, two-winding transformers used for supplying power, heating, and lighting loads for commercial, institutional, and industrial us
22、e in nonhazardous locations both indoors and outdoors. It also covers periodic routine maintenance and troubleshooting procedures for transformers, and special procedures used after adverse operating conditions such as a short-circuit, ground-fault, or immersion in water. 1.2 Products and Applicatio
23、ns Excluded This standard does not include: Transformers with one or more windings rated greater than 1000 Volts AC. Liquid-filled transformers. Autotransformers. Current transformers. Control transformers and transformers used with Class 2 and Class 3 circuits. Dry-type transformers that constitute
24、 a component part of other apparatus and comply with the requirements for such apparatus, including an X-ray, high-frequency, or electrostatic-coating apparatus. Transformers for sign and outline lighting, including electric-discharge lighting. Transformers used for power-limited fire alarm circuits
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSINEIS4092015STANDARDFORINSTALLINGANDMAINTAININGDRYTYPETRANSFORMERSPDF

链接地址:http://www.mydoc123.com/p-437454.html