ANSI IT2.26-1998 Photography - Photographic Materials - Determination of Safelight Conditions《摄影.摄影材料.安全光条件的测定.ANSI PH2.22-1998的修改件和重新设计》.pdf
《ANSI IT2.26-1998 Photography - Photographic Materials - Determination of Safelight Conditions《摄影.摄影材料.安全光条件的测定.ANSI PH2.22-1998的修改件和重新设计》.pdf》由会员分享,可在线阅读,更多相关《ANSI IT2.26-1998 Photography - Photographic Materials - Determination of Safelight Conditions《摄影.摄影材料.安全光条件的测定.ANSI PH2.22-1998的修改件和重新设计》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、STD-ANSI IT2.2b-ENGL 1778 = 072gL50 0558342 917 m- for Photography - Photographic Materials Determination of Safelig iht I ANSUPIMA IT2, :onditions ,26- -1998 This material is reproduced from American National Standard XT 4 2 6 , copyright 1448 , with permission of the American National Standards In
2、stitute, Inc. Not for resale. No part of this publication may be copied or reproduced in any form, electronic retrieval system or otherwise, without the prior written permission of the American National Standards Institute, Inc., 11 West 42nd Street, New York, New York 10036. - -!rra American Nation
3、al Standards Institute 77 West 42nd Street New York, New York 10036 ANSVPIMA lT2.26-1998 Revision and redesignation of ANSI PH2.22-1988 American National Standard for Photography - Photographic Materials - Dete rm in at ion of Safe I ig h t Conditions Secretariat Photographic their existence does no
4、t in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances gi
5、ve an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the secretariat or s
6、ponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard.
7、 Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by American National Standards Institute, Inc. 11 West 42nd Street, New York, NY 10036 Copyright O 1998 by American National Standard
8、s Institute All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America Contents Page Foreword i Introduction . III 1 Scope . 1 . 2 Normative
9、 references . 1 Maintenance and recording of safelight conditions 3 Evaluation of safelight conditions used during processing . 9 3 Definitions . 1 4 5 Test methods 3 6 7 Evaluation . 10 8 Designation . 11 Fig u res 1 2 3 Partition mask . 7 4 Step mask . 8 Annexes A Safelight testing using halftone
10、images 12 6 Bibliography 14 Typical strip after processing (unsafe condition) . 5 Format of three-partition safelight test 6 I Foreword (This foreword is not part of American National Standard ANSI/PIMA lT2.26-1998.) This standard is based upon an IS0 Committee Draft of the revision of IS0 8374:1986
11、, and it is considered to be a significant improvement over the existing na- tional standard, ANSI PH2.22-1988. Once the work on the revision of IS0 8374 reaches the FDIS stage, Technical Committee IT2 will submit it to ballot for adoption as a joint ANSI/ISO standard. This standard contains two ann
12、exes. Annex A is normative and is considered part of this standard. Annex B is for information only. Suggestions for improvement of this standard will be welcome. They should be sent to the Photographic in such cases, a simple fog test would be adequate. 2 ANSVPIMA lT2.26-1998 4 Maintenance and reco
13、rding of safelight conditions A record shall be made of all pertinent data including the safelight source type (e.g., light-emitting diode, electroluminescent panel, tungsten bulb, sodium vapor lamp, etc.), source wattage or milliamp draw, volt- age, filter used (if any), approximate age of the filt
14、er, type and interior finish (e.g., white, matte black, sil- vered, etc.) of the safelight fixture, distance from the safelight to the sensitized material, exposure times, and processing data. The data for indirect safelight illumination (aimed at walls or ceilings) shall also in- clude the color an
15、d reflectance of the surfaces and appropriate geometrical descriptions. Once established, the safelight exposure variable shall be maintained by ensuring that proper replacement lamps are used, that filters are not fading, that the distance from the safelight to the sensitized material is maintained
16、, and that the environment has not changed (by painting walls, etc.). Any changes to the elements described above shall be evaluated individually via the methods set forth in this standard. 5 Test methods This clause describes two methods of testing to determine the maximum safelight condition. Meth
17、od 1 (see 5.1): The most general and the one that shall be used when the safelightlmaterial relation- ship is unknown. It makes no assumptions regarding: (a) the image density at which the safelight exposure produces the maximum effect; (b) the order of exposures (safelight and image) that produces
18、the maximum effect. Method 2 (see 5.2): Intended for use only when the basic relationship between the safelight and the sen- sitized material is already known. It is thus useful for “in situ“ testing of safelit areas, once Method 1 has yielded the safelightlmaterial relationship. (Method 1 may also
19、be used for “in situ“ testing, but it is more cumbersome than Method 2.) In Method 2, the image exposure is simulated by a uniform exposure that produces the greatest sensitivity to subsequent safelight exposure. (in some cases, the material may be most sensitive over a range of densities from fog u
20、pwards; here, Method 2 can be reduced to a simple fog test.) The description in 5.2 includes testing both orders of exposures (safelight then image, and image then safelight); but if the order producing the greatest safelight sensitivity is known, or if only one order is relevant (e.g., in an area w
21、here photographic materials are manufactured), then the other order may be omitted. Method 2 can be accomplished using a single sheet of sensitized material, as opposed to Method 1 which requires several sheets. 5.1 Method 1 5.1.1 Principle Separate samples are subjected to a series of safelight exp
22、osures before the image exposure and after the image exposure. The maximum safelight exposure that does not affect the image, and also the expo- sure required to produce the smallest detectable change, are determined and used to define the “IS0 maximum safelight condition.“ Alternatively, if one has
23、 already determined whether a given sensitized product shows the first detectable change in the unexposed areas or in the exposed areas at a particular density, the safelight series may be performed on one sample (Method 2, see 5.2). 3 ANSVPIMA lT2.26-1998 5.1.2 Apparatus 5.1.2.1 Step tablet The use
24、 of a transmission step tablet is recommended to create a series of stepped exposures that will provide the range of densities expected in the normal use of the material to be evaluated. For products normally exposed with direct X-rays, the exposure series shall be obtained in a manner appropriate f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIIT2261998PHOTOGRAPHYPHOTOGRAPHICMATERIALSDETERMINATIONOFSAFELIGHTCONDITIONS 摄影 材料 安全 条件 测定 ANSIPH2221998

链接地址:http://www.mydoc123.com/p-437301.html