ANSI CTA-2045.2-2014 Modular Communications Interface for Generic Display Message Set (Formerly ANSI CEA-2045.2).pdf
《ANSI CTA-2045.2-2014 Modular Communications Interface for Generic Display Message Set (Formerly ANSI CEA-2045.2).pdf》由会员分享,可在线阅读,更多相关《ANSI CTA-2045.2-2014 Modular Communications Interface for Generic Display Message Set (Formerly ANSI CEA-2045.2).pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 ANSI/CTA Standard Modular Communications Interface for Generic Display Message Set ANSI/CTA-2045.2 (Formerly ANSI/CEA-2045.2) July 2014 NOTICE Consumer Technology Association (CTA) Standards, Bulletins and other technical publications are designed to serve the public interest through eliminating mi
2、sunderstandings between manufacturers and purchasers, facilitating interchangeability and improvement of products, and assisting the purchaser in selecting and obtaining with minimum delay the proper product for his particular need. Existence of such Standards, Bulletins and other technical publicat
3、ions shall not in any respect preclude any member or nonmember of the Consumer Technology Association from manufacturing or selling products not conforming to such Standards, Bulletins or other technical publications, nor shall the existence of such Standards, Bulletins and other technical publicati
4、ons preclude their voluntary use by those other than Consumer Technology Association members, whether the standard is to be used either domestically or internationally. Standards, Bulletins and other technical publications are adopted by the Consumer Technology Association in accordance with the Ame
5、rican National Standards Institute (ANSI) patent policy. By such action, the Consumer Technology Association does not assume any liability to any patent owner, nor does it assume any obligation whatever to parties adopting the Standard, Bulletin or other technical publication. This document does not
6、 purport to address all safety problems associated with its use or all applicable regulatory requirements. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations before its use. This docu
7、ment is copyrighted by the Consumer Technology Association and may not be reproduced, in whole or part, without written permission. Federal copyright law prohibits unauthorized reproduction of this document by any means. Organizations may obtain permission to reproduce a limited number of copies by
8、entering into a license agreement. Requests to reproduce text, data, charts, figures or other material should be made to the Consumer Technology Association. (Formulated under the cognizance of the CTA R7.8 Modular Communication Interface for Energy Management Subcommittee.) Published by CONSUMER TE
9、CHNOLOGY ASSOCIATION 2015 Technology Phone 800-699-9277; Fax 734-780-2046; Internet http:/; Email 2.2 Compliance Notation As used in this document “shall” and “must” denote mandatory provisions of the standard. “Should” denotes a provision that is recommended but not mandatory. “May” denotes a feat
10、ure whose presence does not preclude compliance, and implementation of which is optional. “Optional” denotes items that may or may not be present in a compliant device. 2.3 Definitions and Abbreviations Big-Endian Specifies that the transmission byte order of a data stream is MSB first LSB Least Sig
11、nificant Byte e.g. for the value 0x12345678, 0x78 is the LSB LSN Bits 23through 20e.g. the LSN of 0xAB is 0xB MSB Most Significant Byte e.g. for the value 0x12345678, 0x12 is the MSB MSN Bits 27through 24e.g. the MSN of 0xAB is 0xA 3 Nibble Four bit value obtained by dividing a byte in half SGD Smar
12、t Grid Device the end device that is being informed of grid conditions SINT8 Eight-bit signed value (ones compliment) SINT16 16-bit signed value (ones compliment) UCM Universal Communications Module the communications device that provides communication connectivity to an SGD UINT8 Eight-bit unsigned
13、 value UINT16 16-bit unsigned value UINT32 32-bit unsigned value 3 Message Set The Generic Display message set is an extension of the ANSI/CEA-2045 Intermediate DR message set (Message Type = 0x08, 0x02). Unlike the Basic DR Application message set, which is fixed at 8 bytes total message length, In
14、termediate DR application messages have variable lengths. Some message definitions include Null terminated strings which causes the length of the packet to be content specific. Prior to sending any of the messages defined in this specification, the device must negotiate the maximum payload size usin
15、g the “Query: Maximum payload length?“ and “Response: Maximum payload length“ messages defined in Section 6 of ANSI/CEA-2045. ANSI/CEA-2045 prohibits transfer of serial messages that would overflow buffers of the recipient. Intermediate DR commands are all optional, however if the device supports th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSICTA204522014MODULARCOMMUNICATIONSINTERFACEFORGENERICDISPLAYMESSAGESETFORMERLYANSICEA20452PDF

链接地址:http://www.mydoc123.com/p-434579.html