ANSI ASTM F1755M-1996 Standard Specification for Solid State Bargraph Meters for Shipboard Use [Metric].pdf
《ANSI ASTM F1755M-1996 Standard Specification for Solid State Bargraph Meters for Shipboard Use [Metric].pdf》由会员分享,可在线阅读,更多相关《ANSI ASTM F1755M-1996 Standard Specification for Solid State Bargraph Meters for Shipboard Use [Metric].pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1755M 96 (Reapproved 2012)1An American National StandardStandard Specification forSolid State Bargraph Meters for Shipboard Use Metric1This standard is issued under the fixed designation F1755M; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEReapproved with editorial changes in October 2012.1. Scope1.1 This specification provid
3、es the requirements for design,construction, performance, and testing of solid state bargraph-type indicating meters.1.2 The solid state bargraph meters covered by this speci-fication are intended for use in shipboard applications ofelectrical measurement. This specification covers the require-ments
4、 and quality assurance provisions for solid state, panel-type (edgewise), and rectangular switchboard-typeinstruments, which use light-emitting diodes (LEDs) for bar-graph indication and optional digital displays.1.3 This specifications requirements may be invoked forspecialized measurement applicat
5、ions where another quantity,for example, position, weight, concentration of a trace elementin an atmosphere sample, and so forth, is converted to electricalenergy for display and measurement. Special dial markingsshall be specified for such cases.1.4 The values stated in metric units are to be regar
6、ded asthe standard. The values given in parentheses are for informa-tion only.2. Referenced Documents2.1 ASTM Standards:2B117 Practice for Operating Salt Spray (Fog) ApparatusD3951 Practice for Commercial PackagingF1166 Practice for Human Engineering Design for MarineSystems, Equipment, and Faciliti
7、es2.2 Federal Specifications:TTE529 Enamel, Alkyd, Semigloss, Low VOC Content32.3 Federal Standards:H28 Screw Thread Standards for Federal Services33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 accuracy, nthe accuracy is a number that defines thelimit of errors expressed as
8、a percentage of full-scale value.3.1.2 center-zero meter, nmeter with display mode char-acterized by a sequentially illuminated string of LEDs startingat the center scale zero position and extending in eitherdirection from zero, proportional to the polarity and magnitudeof the input signal.3.1.3 dua
9、l bargraph display, ntwo completely indepen-dent bargraph displays included in a single enclosure.3.1.4 end-scale value, nthe value of the actuating electri-cal quantity that corresponds to end scale indication. Whenzero is not at the end or at the electrical center of the scale, thehigher value is
10、used. See Table 1.3.1.5 end-zero meter, nmeter with display mode charac-terized by a sequentially illuminated string of LEDs startingfrom a zero point, normally at the left for switchboard-stylemeters or horizontally installed edgewise meters, or the bottomof vertically installed edgewise meters, th
11、at extends in thedirection of full-scale value.3.1.6 full-scale value, nfull-scale value is the largest valueof the actuating electrical quantity that can be indicated on thescale. For instruments with zero between the ends of the scale,the full-scale value is the arithmetic sum of the values of the
12、actuating electrical quantity corresponding to the two ends ofthe scale.3.1.7 response time, nthe response time is the time re-quired for the indicating means to display a new value after astep change has occurred in the measured quantity to a newconstant value.3.1.8 scale division, na scale divisio
13、n is the incrementbetween the centers of two consecutive scale marks. Thenumber of scale marks is one more than the number of scaledivisions. For example, 10 scale divisions require 11 scalemarks.1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is
14、 the direct responsibility of Subcommittee F25.10 onElectrical.Current edition approved Oct. 1, 2012. Published November 2012. Originallyapproved in 1996. Last previous edition approved in 2007 as F1755M - 96(2007).DOI: 10.1520/F1755M-96R12E01.2For referenced ASTM standards, visit the ASTM website,
15、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 191115098,
16、 ATTN: NPODS.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.8.1 linear scale divisions, nlinear scale divisions arescale divisions that are spaced an equal distance apart and ofthe same value, for example, scale divisions spaced
17、5 A aparton a 100A meter.3.1.8.2 nonlinear scale divisions, nnonlinear scale divi-sions are scale divisions of the same value spaced an unequaldistance apart.3.1.9 scale length, nthe scale length is the length of thepath described by the pattern of the LEDs in moving from oneend of the scale to the
18、other. For multiple scale meters, thelongest scale shall be used to determine the scale length.3.1.10 scale visibility, nscale visibility is the maximumhorizontal or vertical viewing angle measured from a linenormal to the scale from which all scale marks and arcs, but notnecessarily all markings, m
19、ay be seen.4. Classification4.1 Classification Bargraph meters covered in this speci-fication shall be classified by type and style as specified in4.2-4.3.4.2 TypeThe type designation defines the physical con-figuration of the meter and the scale.4.2.1 Rectangular/switchboard-type meters present ang
20、ulardisplays from 90 to 270 scale for the measured parameter(s).Fig. 1 provides typical dimensional and mounting data forrectangular/switchboard-type meters.4.2.2 Edgewise/panel-type meters present linear displaysfor measured parameters. Fig. 2 provides typical dimensionaland mounting data for edgew
21、ise type meters.4.2.2.1 Orientation of MeterFor edgewise/panel-typemeters, the scale marking shall be specified either for a verticalor horizontal mounting condition.4.3 StyleThe style designation defines the meters displayattributes as follows:4.3.1 Bargraph DisplayThe bargraph display shall consis
22、tof light-emitting diode (LED) elements that illuminate toproduce a bar image proportional to the input signal. Thedisplay designation defines whether the meter has single ordual bargraph displays.4.3.2 Digital DisplayThe digital display designation de-fines the number of digits in the digital displ
23、ay as follows:4.3.2.1 3-digit display.4.3.2.2 312-digit display.4.3.2.3 4-digit display.4.3.2.4 412-digit display4.3.2.5 No digital display.5. Ordering Information5.1 Purchase orders or inquiries for bargraph meters of thisspecification shall specify the following:5.1.1 Title, date, and year of this
24、 specification.5.1.2 Quantity.5.1.3 Type, and for edgewise meter, orientation (see 4.2).5.1.4 Style of display (single or dual, digital display) (see4.3).5.1.5 Window type (plastic or shatterproof glass) (see 7.5).5.1.6 Dial colors (see 7.9.1.1).5.1.7 Range(s) (see 7.9.2).5.1.8 Power supply voltage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMF1755M1996STANDARDSPECIFICATIONFORSOLIDSTATEBARGRAPHMETERSFORSHIPBOARDUSEMETRICPDF

链接地址:http://www.mydoc123.com/p-432904.html