1、Designation: D7082 15 An American National StandardStandard Specification forPolyethylene Stay In Place Form System for End Walls forDrainage Pipe1This standard is issued under the fixed designation D7082; the number immediately following the designation indicates the year oforiginal adoption or, in
2、 the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification addresses the requirements for poly-ethylene stay in place form
3、s for end walls or head walls for usewith standard storm drainage systems.1.2 The wall form system consists of a base wall form, acap, an optional riser to adjust the height of the wall above thepipe, and an optional adaptor to adjust the pipe opening toaccommodate smaller pipe sizes.1.3 The form sy
4、stem is manufactured using the rotationalmolding process and is available in different colors.1.4 The values stated in SI units are to be regarded as thestandard, the inch-pounds in parentheses are given for infor-mation only.1.5 This standard does not purport to address all of thesafety concerns, i
5、f any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Documents2.1 ASTM
6、Standards:2D638 Test Method for Tensile Properties of PlasticsD648 Test Method for Deflection Temperature of PlasticsUnder Flexural Load in the Edgewise PositionD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating Materi-alsD883 Terminology Relat
7、ing to PlasticsD1238 Test Method for Melt Flow Rates of Thermoplasticsby Extrusion PlastometerD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1693 Test Method for Environmental Stress-Cracking ofEthylene Plastics
8、D4883 Test Method for Density of Polyethylene by theUltrasound Technique3. Terminology3.1 Definitions:3.1.1 Definitions used in this specification are in accordancewith definitions in Terminology D883 and abbreviations inaccordance with Terminology D1600 unless otherwise indi-cated.3.1.2 end walla w
9、all installed at the outlet of a stormdrainage pipe.3.1.3 head walla wall installed at the inlet of a stormdrainage pipe.4. Ordering Information4.1 Number and color of base wall forms,4.2 Number and color of riser forms,4.3 Number and color of caps, and4.4 Number, color and size of adaptors.5. Mater
10、ials and Manufacture5.1 The material used shall be a polyethylene meeting thecriteria in Table 1.5.2 Only virgin materials shall be used.5.3 This product shall be manufactured using a rotationalmolding process.6. Requirements6.1 Wall System Description:6.1.1 Base wall form is hollow with opening at
11、the top toaccept fill material and designed to accept either cap or risersection. Base wall has opening in the center for pipe andadaptors as needed. Pipe is secured to base wall form withgalvanized screws. (See Fig. 1.)1This specification is under the jurisdiction of ASTM Committee D20 onPlastics a
12、nd is the direct responsibility of Subcommittee D20.24 on Plastic BuildingProducts.Current edition approved Oct. 1, 2015. Published October 2015. Originallyapproved in 2004. Last previous edition approved in 2010 as D7082 - 04(2010).DOI: 10.1520/D7082-15.2For referenced ASTM standards, visit the AST
13、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Ha
14、rbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.1.2 Riser form is hollow with opening at top to accept fillmaterial and cap section. Multiple risers can be installed onbase wall. (See Fig. 2.)6.1.3 Cap fits on top of base wall or riser and is secured withgalvanized screws.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIASTMD70822015STANDARDSPECIFICATIONFORPOLYETHYLENESTAYINPLACEFORMSYSTEMFORENDWALLSFORDRAINAGEPIPEPDF

链接地址:http://www.mydoc123.com/p-432461.html