ANSI American Society of Sanitary Engineering 1071-2012 Performance Requirements for Temperature Actuated Mixing Valves for Plumbed Emergency Equipment.pdf
《ANSI American Society of Sanitary Engineering 1071-2012 Performance Requirements for Temperature Actuated Mixing Valves for Plumbed Emergency Equipment.pdf》由会员分享,可在线阅读,更多相关《ANSI American Society of Sanitary Engineering 1071-2012 Performance Requirements for Temperature Actuated Mixing Valves for Plumbed Emergency Equipment.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、Temperature Actuated Mixing Valves for Plumbed Emergency Equipment 1ASSE 1071-2012Performance Requirements forTemperature Actuated Mixing Valves for Plumbed Emergency EquipmentAmerican Society of Sanitary EngineeringASSE Standard #1071-2012ASSE Board Approved: August, 2012ANSI Approved: October, 201
2、2An American National StandardTemperature Actuated Mixing Valves for Plumbed Emergency Equipment iASSE 1071-2012General InformationNeither this standard, nor any portion thereof, may be reproduced without the written consent of the American Society of Sanitary Engineering.No product may be said to b
3、e ASSE listed unless the manufacturer has applied to ASSE, has had its product tested according to the applicable standards, the product has passed the test and displays the ASSE Seal on the product.Instructions for receiving the authorization to display the Seal are available from ASSEs Internation
4、al Office. Organizations wishing to adopt or list any ASSE Standard should print the ASSE Standard number on the cover page first and in equal or larger type to that of the adopting or listing organization.American Society of Sanitary EngineeringWestlake, OhioCopyright 2012, 2008All Rights reserved.
5、ii Temperature Actuated Mixing Valves for Plumbed Emergency EquipmentASSE 1071-2012Temperature Actuated Mixing Valves for Plumbed Emergency Equipment iiiASSE 1071-2012ForewordThis foreword is not a part of the standard. However, it is offered to provide background information.Water mixing, also defi
6、ned as tempering or blending, valves are used extensively in applications for emergency shower/eye and face wash systems to mix hot and cold water to provide “tepid” water. The term “tepid” has not been specifically defined, but is generally understood to mean “lukewarm” or “moderately warm.”These d
7、evices, while designed for automatic control of the hot water temperature within a reasonable degree of uniformity, should not be confused or used in place of ASSE Standard 1016, 1017, 1069 or 1070 devices. Valves designed to meet this standard are intended to be used as a component that can provide
8、 tepid water for emergency eye wash and shower equipment that comply with the requirements of ANSI Z358.1, American National Standard for Emergency Eyewash and Shower Equipment. These valves, by themselves, do not meet the requirements of ANSI Z358.1.In circumstances where chemical reaction is accel
9、erated by flushing fluid temperature, per ANSI Z358.1, a medical advisor should be consulted for the optimum temperature for each application.The working group, which developed this standard revision, was set up within the framework of the Product Standards Committee of the American Society of Sanit
10、ary Engineering.Recognition is made of the time volunteered by members of this working group and of the support of the manufacturers who also participated in the meetings for this standard.This standard does not imply ASSEs endorsement of a product which conforms to these requirements.Compliance wit
11、h this standard does not imply acceptance by any code body.It is recommended that these devices be installed consistent with local codes by qualified and trained professionals.This standard was promulgated in accordance with procedures developed by the American National Standards Institute (ANSI).Th
12、is edition of the standard was approved by the ASSE Board of Directors on August 30, 2012 as an ASSE standard.iv Temperature Actuated Mixing Valves for Plumbed Emergency EquipmentASSE 1071-2012Joseph Fugelo, ChairmanLabov Co.Philadelphia, Pennsylvania Rand AckroydRand Technical Consulting, LLCNewbur
13、yport, Massachusetts William Briggs Jr.MGJ AssociatesNew York, New YorkMaribel CamposICC Evaluation ServicesWhittier, CaliforniaJudson CollinsJULYCOMannford, OklahomaRon GeorgePlumb-Tech Design & Consulting Services, LLCNewport, MichiganJohn F. Higdon P.E.Apollo Valves / Conbraco Industries, Inc.Mat
14、thews, North CarolinaJim Kendzel, MPH, CAEAmerican Society of Plumbing EngineersDes Plaines, Illinois2012 Product Standards Committee Chuck LottPrecision Plumbing ProductsPortland, OregonPeter MarzecUnited Association of Plumbers and PipefittersPearl River, New YorkRamiro MataASSE Staff EngineerWest
15、lake, OhioAbraham MurraIAPMO R&TOntario, CaliforniaBrad NollWilkins / A Division of ZurnPaso Robles, CaliforniaThomas PitcherelloState of New JerseyBordentown, New JerseyShabbir RawalpindiwalaKohler CompanyKohler, WisconsinTsan-Liang Su, PhDStevens Institute of TechnologyHoboken, New Jersey Temperat
16、ure Actuated Mixing Valves for Plumbed Emergency Equipment vASSE 1071-2012Rand Ackroyd, ChairmanRand EngineeringNewburyport, Massachusetts Richard CotaLeonard Valve Co.Cranston, Rhode IslandNed DickeyCSA InternationalCleveland, OhioTom EberhardyBradley CorporationMenomonee Falls, WisconsinRobert Eve
17、leighLawler Manufacturing Co.Indianapolis, IndianaMatt FratantonioWatts Water TechnologyNorth Andover, MassachusettsJim GalvinPlumbing Manufacturers InternationalSarasota, FloridaRon GeorgePlumb-Tech Design & Consulting Services, LLCNewport, MichiganSteve GregoryVernet SANew Palestine, IndianaWillia
18、m HallLeonard ValveCranston, Rhode Island1071 Working GroupSteven HazzardASSE Staff EngineerWestlake, OhioTim KilbaneSymmons Industries, Inc.Braintree, Massachusetts Mat LunnLawler Manufacturing Co.Indianapolis, IndianaSara MarxenASSE Compliance CoordinatorWestlake, OhioMargo MeeHaws CorporationSpar
19、ks, NevadaRyan PfundBradley CorporationMenomonee Falls, WisconsinBert RodriguezApollo Valves/Conbraco IndustriesPageland, South CarolinaPurvez SaeedPowers, A Watts Technologies CompanyBuffalo Grove, IllinoisKen Van WagnenASSE Standards CoordinatorWestlake, Ohiovi Temperature Actuated Mixing Valves f
20、or Plumbed Emergency EquipmentASSE 1071-2012Table of ContentsSection I . 11.0 General 11.1 Application .11.2 Scope .1Table 1 21.3 Reference Standards 2Section II 42.0 Test Specimens .42.1 Samples Submitted 42.2 Samples Tested .42.3 Drawings 42.4 Rejection 4Section III. 53.0 Performance Requirements
21、and Compliance Testing .53.1 Conditioning Test 5Figure 1 63.2 Temperature Control Test 73.3 Hot Water Shut-Off Test .73.4 Maximum Outlet Temperature Test 83.5 Cold Water Shut-Off Test .83.6 Cross Flow Test .83.7 Hydrostatic Pressure Test 9Section IV 104.0 Detailed Requirements 104.1 Installation and
22、 Maintenance Instructions 104.2 Identification and Markings .10Section V 115.0 Definitions 11Temperature Actuated Mixing Valves for Plumbed Emergency Equipment 1ASSE 1071-2012Temperature Actuated Mixing Valves for Plumbed Emergency Equipment Section I1.0 General1.1 ApplicationTemperature Actuated Mi
23、xing Valves for Plumbed Emergency Equipment (herein referred to as the “device”), including eyewash, eye/face wash, drench showers and combination units, are intended to be installed in systems that comply with ANSI Z358.1.1.2 Scope1.2.1 DescriptionThese devices shall consist of a hot water inlet co
24、nnection, a cold water inlet connection, a mixed water outlet connection, a temperature controlling element and a means for adjusting the mixed water outlet temperature while in service. The device shall also have a means to limit the maximum outlet temperature under normal operating conditions. Pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ANSIAMERICANSOCIETYOFSANITARYENGINEERING10712012PERFORMANCEREQUIREMENTSFORTEMPERATUREACTUATEDMIXINGVALVESFORPLUMBEDEMERGENCYEQUIPMENTPDF

链接地址:http://www.mydoc123.com/p-430874.html