1、 - MIL-PRF-25370F 9999906 203b570 300 MIL-PRF-253 70F 09 May 1997 SUPERSEDING 12 July 1994 MIL-L-25 3 70E(uSAF) PERFORMANCE SPECIFICATION VALVE, PNEUMATIC INFLATOR (LIFE PRESERVER, MA-1) This specification is approved for use by all Departments and Agencies of the Department of Defense. 1. SCOPE 1-1
2、 MA-1). Scope. This specification covers one type of pneumatic inflator valve (life preserver, 2. APPLICABLE DOCUMENTS 2.1 General. The documents listed in this section are cited in sections 3 and 4 of this specification. These lists do not include documents cited in other sections of this specifica
3、tion or recommended for additional information or as examples. While every effort has been made to ensure the completeness of these lists, document users are cautioned that they must meet all specified requirements documents cited in sections 3 and 4 of this specification, whether or not they are li
4、sted. 2.2 Government documents. 2.2.1 Specifications and standards. The following specifications and standards form a part of this document to the extent specified herein. Unless otherwise specified, the applicable issues o Beneficial comments (recommendations, additions, deletions) and any pertinen
5、t data that may be of use in improving this document should be addressed to: Resources & Logistics Services Division, SA-ALC/TILDD, 485 Quentin Roosevelt Road, Kelly AFB TX 78241-6425, by using the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of this document or
6、by letter. AMSC N/A FSC 4220 DISTRIBUTION STATEMENT A. Approved for public release: distribution is unlimited. Licensed by Information Handling ServicesMIL-PRF-253 70F these documents are those listed in the specific issue of the Department of Defense hdex of Specifications and Standards (DoDISS) an
7、d supplement thereto, cited in the solicitation (see 6.2). SPECIFICATIONS DEPARTMENT OF DEFENSE MIL-PRF-25369 - Cylinders, Carbon Dioxide, For the Inflation of Pneumatic Life Preservers (Unless otherwise indicated, copies of the above specification are available from the Defense Automated Printed Se
8、rvice, Bldg 4D (DPM-DODSSP), 700 Robbins Avenue, Philadelphia PA 191 11-5094) 2.3 Non-Government publications. The following document(s) form a part of this document to the extent specified herein. Unless otherwise specified, the applicable issues of the documents which have been adopted by the DoD
9、are those listed in the specific issue of the DoDISS cited in the solicitation. Unless otherwise specified, the documents not listed in the DoDISS are the issues of the documents cited in the solicitation (see 6.2). AMERICAN SOCIETY FOR QUALITY CONTROL ANSUASQC Z 1.4- 1993 - Sampling Procedures and
10、Tables for Inspection by Attributes (Application for copies should be addressed to the American Society for Quality Control, 6 1 1 East Wisconsin Avenue, P.O. Box 3005, Milwaukee, Wisconsin 53201 -3005) AMERICAN SOCIETY FOR TESTING AND MATERTALS (ASTM) - ASTM-B-117 - Standard Test Method of Salt Spr
11、ay (FOG) Testing (Application for copies should be addressed to the American Society For Testing and Materials, 1916 Race Street, Philadelphia, Pennsylvania 19103-1 187) 2.4 references cited herein (except for related associated specifications or specification sheets), the text of this document take
12、s precedence. Nothing in this document, however, supersedes applicable laws and regulations unless a specific exemption has been obtained. If there is a conflict between the contents of this specification and an associated specification or specification sheet, the associated specification or specifi
13、cation sheet should apply. Order of precedence . In the event of a conflict between the text of this document and the 3. REQUIREMENTS 3.1 General. Figure 1 represents a general concept of a pneumatic inflator valve. It should be used for general dimensional purposes such as length, width and thickne
14、ss but should not be 2 Licensed by Information Handling ServicesMIL-PRF-25370F 9799906 203b572 183 MIL-PRF-25 370F construed as the only possible design approach. 3.2 article inspection in accordance with 4.5. First article. When a first article is specified (see 6.2 and 6.4) it shall be subjected t
15、o first 3.3 component parts used in the inflator valve shall have been manufactured not more than 12 months prior to the date of delivery to the Government. &. Unless otherwise specifically approved by the procuring activity, all materials and 3.4 decomposition, fungus, salt spray, and any other atm
16、ospheric condition that may be encountered during operational use or storage. Materials. All materials shall be suitably treated to resist corrosion due to electrolytic 3.5 Rl. Recycled, recovered, or environmentally preferable materials should be used to the maximum extent possible provided that th
17、e materials meet or exceed the operational or maintenance requirements, and promote economically advantageous life cycle costs. 3.6 world-wide environmental conditions expected to be encountered by aircrew personnel. The unit shall function easily by personnel wearing standard flight gear. peration.
18、 The pneumatic infiator valve shall be capable of being easily operated in 3.6.1 with the infiator valve housing in the unopened position. The actuator shall be secured in the unopened position. The inflator valve shall consist of a piercing mechanism that will retract immediately fi-om the opening
19、of the punctured cylinder, and have a seal that shall prevent leakage of the life preserver cell with the actuator in any position. The inlet of the inflator valve shall be threaded to accept a carbon dioxide cylinder conforming to MIL-PRF-25369. A locking mechanism shall be provided to retain the c
20、arbon dioxide cylinder in the inlet. An outlet shall be provided to mount the inflator valve on the life preserver cell valve stem as shown in Figure 2. A passage shall be provided for conducting gas fi-om the punctured carbon dioxide cylinder to the outlet when actuated. The outlet shall align with
21、 the hole in the side of the stem regardless of which side of the outlet is toward the base of the stem. Inflator valve housing. The inflator valve shall consist of an actuator that shall be flush 3.6.2 Valve stem cap. A valve stem cap (see figure 2) shall be provided to hold the inflator valve in p
22、lace on the valve stem. 3.7 Performance. 3.7.1 operate the piercing mechanism. linder. An actuating load of not more than 20 pounds shall 3.7.2 dioxide cylinder conforming to MIL-PRF-25369 for the life of the infiator valve. The Piercing mechanism. The piercing mechanism shall be capable of puncturi
23、ng a carbon 3 Licensed by Information Handling Services MIL-PRF-25370F 9999906 2036573 OLT MIL-PRF-25370F mechanism shall be positioned so as not to accidentally puncture the cylinder due to vibrations or other motion encountered in an operational or storage environment. 3.7.3 pressure of 1500 psi w
24、ithout deformation or leakage. Hydrostatic pressure. The inflator valve shall satisfactorily withstand a hydrostatic 3.7.4 Salt spray. The inflator valve shall operate properly after exposure to a salt spray environment. 3.7.5 Leakage. The inflator valve shall display no evidence of leakage during n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILPRF25370F1997VALVEPNEUMATICINFLATORLIFEPRESERVERMA1 救生 工具 MA1 气动 充气 PDF

链接地址:http://www.mydoc123.com/p-428173.html