1、MIL-C-25548C (2) 1 INCH-POUND I MIL-C-25548C (USAF) AMENDMENT 2 7 SEPTEMBER 1994 SUPERSEDING AMENDMENT 1 26 MAR 84 MILITARY SPECIFICATION CONTROL, PUBLIC ADDRESS SET C-1614/AIC-13 This amendment forms a part of Military Specification MIL-C-25548C (USAF) dated 18 June 1970 and is approved for use by
2、the Depaxtment of the Air Force and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 * 1.1: Add after the first sentence: “This specification may be used or Control, Public Address Set C-3944(P)/AIC-13. When C-1614/AIC-13 is stated in this document, C-3944(P)
3、/AIC-13 may be substituted and applied accordingly. The only difference between these controls is that the latter uses 6 volts for its panel lighting. This difference will be addressed in paragraphs 3.2.5.1 and 4.5.2.“ 2.1 Delete: “MIL-E-5272“ and its title. Add : “MIL-STD-810, Environmental Test Me
4、thods.“ * Add : The headings “HANDBOOK“ and “MILITARY“ and list “MIL- HDBK-781“ - “Reliability Test Methods, Plans, and Environments for Engineering Development, Qual if icat ion , and Product ion. PAGE 3 * Add: 3.2.5.1: Control, Public Address Set C-3944(P)/AIC-13 uses a lamp voltage of 6 volts ins
5、tead of that specified for C-1614/AIC-13. The appropriate nomenclature shall be used on the circuit label.“ PAGE 6 and PAGE 7 * 4.3.2 Table IV, DELETE: .“Salt Spray, Temperature Shock, Sand and Dust, and Fungus.“ SUBSTITUTE: “Salt Fog and Explosive Atmosphere.“ AMSC N/A 1 of 3 FSC 5831 DISTRIBUTION
6、STATEMENT A: Approved for public release; distribution is unlimited. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-25548C (USAF) AMENDMENT 2 * 4.3.2 Table IV: ADD UNDER THE FOLLOWING HEADINGS: Inspection or Test Paragraph Preproduction Indivi
7、dual s amp1 ing “Environmental Stress 4.5.6 Screening al 1 all PAGE 8 * 4.5.2: Add to the end of the paragraph: “Public Address Set Control C-3944(P)/AIC-13 uses a lamp voltage of 6 volts. Make certain that the test circuit does not put 27 volts into the lamp circuit.“ 4.5.4: Delete and substitute:
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AIRFORCEMILC25548C21994CONTROLPUBLICADDRESSSETC1614AIC13C1614AIC13 公共 地址 控制系统 PDF

链接地址:http://www.mydoc123.com/p-427547.html