《AECMA PREN 3475-302-2004 Aerospace Series Cables Electrical Aircraft Use Test Methods Part 302 Voltage Proof Test Issue P 2《航天系列 飞行器用的电缆试验方法.第302部分.耐电压测试》.pdf》由会员分享,可在线阅读,更多相关《AECMA PREN 3475-302-2004 Aerospace Series Cables Electrical Aircraft Use Test Methods Part 302 Voltage Proof Test Issue P 2《航天系列 飞行器用的电缆试验方法.第302部分.耐电压测试》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、AECMA STANDARD NORME AECMA AECMA NORM Edition approved for publication Comments should be sent within six months after the date of publication to 31 December 2004 AECMA-STAN prEN 3475-302 Edition P 2 December 2004 Electrical Domain ICs: 49.060 Supersedes issue P 1 of August 1992 and will supersede E
2、N 3475-302:2002 Descriptors: ENGLISH VERSION Aerospace series Cable, electrical, aircraft use Test methods Part 302: Voltage proof test Srie arospatiale Luft- und Raumfahrt Mthodes dessais Prfverfahren Cbles lectriques a usage aronautique Partie 302 : Tenue en tension Elektrische Leitungen fr Luftfa
3、hrtverwendung Teil 302: Spannungsfestigkeit This “Aerospace Series“ Prestandard has been drawn up under the responsibilify of AECMA-STAN (The European Association of Aerospace Industries - Standardization). It is published for the needs of the European Aerospace Industry. It has been technically app
4、roved by the experts of the concerned Domain following member comments. Subsequent to the publication of this Prestandard, the technical content shall not be changed to an extent that interchangeability is affected, physically or functionally, without re-identification of the standard. After examina
5、tion and review by users and formal agreement of AECMA-STAN, it will be submitted as a draft European Standard (prEN) to CEN (European Committee for Standardization) for formal vote and transformation to full European Standard (EN). The CEN national members have then to implement the EN at national
6、level by giving the EN the status of a national standard and by withdrawing any national standards conflicting with the EN. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without
7、license from IHS-,-,-Page 2 prEN 3475-302:2004 Foreword This standard was reviewed by the Domain Technical Coordinator of AECMA-STANS Electrical Domain. After inquiries and votes carried out in accordance with the rules of AECMA-STAN defined in AECMA- STANS General Process Manual, this standard has
8、received approval for Publication. Contents Page 1 Scope 3 2 Normative references . 3 3 Immersion test . 3 4 Dry spark test (in production) 3 5 Dry impulse test (test in production as an alternative to 4) 4 6 Method . 5 7 Voltage test of components (screened cables) . 5 Copyright Association Europee
9、ne des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Page 3 prEN 3475-302:2004 1 Scope This standard specifies a method of performing voltage proof tests on finished cables and cables i
10、n course of production. It shall be used together with EN 3475-100. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced doc
11、ument (including any amendments) applies. EN 3475-100, Aerospace series - Cables, electrical, aircraft use - Test methods - Part 700: General 3 Immersion test The specimens, each 15 m long, shall be immersed in the solution so that their ends are at least 150 mm from the surface of the solution. The
12、 composition of the solution, at a temperature of between 15 OC and 25 OC, shall be as follows: - sodium chloride 30 g - distilled water 1 O00 g - wetting agent 2g After immersion for 1 h, the voltage specified by the technical specification with a frequency of 40 Hz to 60 Hz, shall be applied betwe
13、en the conductor of the cable and the screen, if present, or an electrode in contact with the liquid for 5 min. Single and multicore (jacketed) without shield: - between the conductor(s) and an electrode in contact with the liquid Shielded and jacketed cables - between the shield and an electrode in
14、 contact with the liquid The voltage rise time shall be between 300 V per second and 500 V per second. There shall be no perforation of the insulation or jacket. 4 Dry spark test (in production) All the finished cables shall pass, without flash-over, through the electrode of a suitable dry tester, a
15、t the voltage stated in the technical specification at a frequency of 40 Hz to 60 Hz. The electrode consists of an assembly of small chains or other metallic feelers suitable for making close contact with practically the whole surface of the cable. The length of the electrode and speed of the cable
16、shall be such that each portion of the insulation or jacket is subjected to the test voltage for at least 0,20 s. Copyright Association Europeene des Constructeurs de Materiel Aerospatial Provided by IHS under license with AECMANot for ResaleNo reproduction or networking permitted without license fr
17、om IHS-,-,-Page 4 prEN 3475-302:2004 The voltage shall be applied: Single and multicore (jacketed) without shield: - between the conductor(s) and the electrode Shielded and jacketed cables - between the shield and the electrode There shall be no perforation of the insulation or jacket. NOTE If a def
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- AECMAPREN34753022004AEROSPACESERIESCABLESELECTRICALAIRCRAFTUSETESTMETHODSPART302VOLTAGEPROOFTESTISSUEP2

链接地址:http://www.mydoc123.com/p-420315.html