ACI 307-2008 Code Requirements for Reinforced Concrete Chimneys (ACI 307-08) and Commentary《钢筋混凝土烟囱的规范要求(ACI 307-08)和注释》.pdf
《ACI 307-2008 Code Requirements for Reinforced Concrete Chimneys (ACI 307-08) and Commentary《钢筋混凝土烟囱的规范要求(ACI 307-08)和注释》.pdf》由会员分享,可在线阅读,更多相关《ACI 307-2008 Code Requirements for Reinforced Concrete Chimneys (ACI 307-08) and Commentary《钢筋混凝土烟囱的规范要求(ACI 307-08)和注释》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、ACI 307-08Reported by ACI Committee 307Code Requirements for ReinforcedConcrete Chimneys (ACI 307-08)and CommentaryAn ACI StandardCode Requirements for Reinforced Concrete Chimneysand CommentaryFirst PrintingNovember 2008ISBN 978-0-87031-307-3American Concrete InstituteAdvancing concrete knowledgeCo
2、pyright by the American Concrete Institute, Farmington Hills, MI. All rights reserved. This materialmay not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or otherdistribution and storage media, without the written consent of ACI.The technical committees res
3、ponsible for ACI committee reports and standards strive to avoid ambiguities,omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionallyfind information or requirements that may be subject to more than one interpretation or may beincomplete or incorre
4、ct. Users who have suggestions for the improvement of ACI documents arerequested to contact ACI. Proper use of this document includes periodically checking for errata atwww.concrete.org/committees/errata.asp for the most up-to-date revisions.ACI committee documents are intended for the use of indivi
5、duals who are competent to evaluate thesignificance and limitations of its content and recommendations and who will accept responsibility for theapplication of the material it contains. Individuals who use this publication in any way assume all risk andaccept total responsibility for the application
6、 and use of this information.All information in this publication is provided “as is” without warranty of any kind, either express or implied,including but not limited to, the implied warranties of merchantability, fitness for a particular purpose ornon-infringement.ACI and its members disclaim liabi
7、lity for damages of any kind, including any special, indirect, incidental,or consequential damages, including without limitation, lost revenues or lost profits, which may resultfrom the use of this publication.It is the responsibility of the user of this document to establish health and safety pract
8、ices appropriate tothe specific circumstances involved with its use. ACI does not make any representations with regard tohealth and safety issues and the use of this document. The user must determine the applicability of allregulatory limitations before applying the document and must comply with all
9、 applicable laws and regulations,including but not limited to, United States Occupational Safety and Health Administration (OSHA) healthand safety standards.Order information: ACI documents are available in print, by download, on CD-ROM, through electronicsubscription, or reprint and may be obtained
10、 by contacting ACI.Most ACI standards and committee reports are gathered together in the annually revised ACI Manual ofConcrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgACI 307-08 supersedes
11、ACI 307-98, was adopted August 19, 2008, and publishedNovember 2008.Copyright 2008, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by anymeans, including the making of copies by any photo process, or by electronic ormechanical device, printed,
12、 written, or oral, or recording for sound or visual reproductionor for use in any knowledge or retrieval system or device, unless permission in writingis obtained from the copyright proprietors.307-1ACI Committee Reports, Guides, Manuals, StandardPractices, and Commentaries are intended for guidance
13、 inplanning, designing, executing, and inspecting construction.This Commentary is intended for the use of individuals whoare competent to evaluate the significance and limitations of itscontent and recommendations and who will acceptresponsibility for the application of the material it contains.The
14、American Concrete Institute disclaims any and allresponsibility for the stated principles. The Institute shall notbe liable for any loss or damage arising therefrom.Reference to this Commentary shall not be made in contractdocuments. If items found in this document are desired by thelicensed design
15、professional to be a part of the contractdocuments, they shall be restated in mandatory language.ACI 307-08This code gives material, construction, and design requirements for cast-in-place and precast reinforced concrete chimneys. It sets forth minimumloadings for design and contains methods for det
16、ermining the concrete andreinforcement required as a result of these loadings. The method of analysisapplies primarily to circular chimney shells; however, a general procedurefor analysis of noncircular shapes is included.Equations are provided for determining the temperature gradient throughthe con
17、crete resulting from the difference in temperature of the gases insidethe chimney and the surrounding atmosphere. Methods for combining theeffects of dead and wind (or earthquake) loads with temperature, bothvertically and circumferentially, are included in this code. These methodspermit the license
18、d design professional to establish minimum concrete andreinforcement requirements.The Commentary discusses some of the background and considerationsof Committee 307 in developing the provisions contained in “CodeRequirements for Reinforced Concrete Chimneys (ACI 307-08).” Twoappendixes provide the d
19、erivation of the equations for nominal strengthand temperature stresses. Commentary provisions begin with an “R,” suchas “R1.1.1,” and are shown in italics.Keywords: chimneys; compressive strength; concrete construction; earth-quake-resistant structures; formwork (construction); foundations; hightem
20、perature; linings; loads (forces); moments; openings; precast concrete;quality control; reinforced concrete; reinforcing steels; specifications;static loads; strength; structural analysis; structural design; temperature;thermal gradient; wind pressure.CONTENTSR0Introduction, p. 307-2Chapter 1General
21、, p. 307-31.1Scope1.2Drawings1.3Regulations1.4NotationChapter 2Materials, p. 307-72.1General2.2Cement2.3Aggregates2.4ReinforcementChapter 3Construction requirements, p. 307-73.1General3.2Concrete strength3.3Strength tests3.4Forms3.5Reinforcement placement3.6Concrete placement3.7Concrete curing3.8Con
22、struction tolerances3.9Precast erectionChapter 4Loads and general design criteria,p. 307-84.1General4.2Wind loadsVictor A. Bochicchio Thomas D. Joseph Robert A. Porthouse Randolph W. SnookJohn J. Carty Jagadish R. Joshi Ronald E. Purkey John C. SowizalSamuel Dilcer Faris A. Malhas Denis J. Radecki B
23、arry J. VickeryShu-Jin Fang David C. Mattes Scott D. Richart Edward L. YordySigmund A. FreemanThe committee acknowledges the late Milton Harstein for his contribution to the development of these code requirements.David J. BirdChairCode Requirements for Reinforced Concrete Chimneys (ACI 307-08) and C
24、ommentaryAn ACI StandardReported by ACI Committee 307307-2 ACI STANDARD4.3Earthquake loads4.4Special design considerations and requirements4.5Wind deflection criteriaChapter 5Design of chimney shells: strength method, p. 307-175.1General5.2Design loads5.3Required strength5.4Design strength5.5Nominal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACI3072008CODEREQUIREMENTSFORREINFORCEDCONCRETECHIMNEYSACI30708ANDCOMMENTARY 钢筋混凝土 烟囱 规范 要求 ACI30708

链接地址:http://www.mydoc123.com/p-401155.html