ABS 191 NOTICE 1-2015 GUIDE FOR DYNAMIC POSITIONING SYSTEMS.pdf
《ABS 191 NOTICE 1-2015 GUIDE FOR DYNAMIC POSITIONING SYSTEMS.pdf》由会员分享,可在线阅读,更多相关《ABS 191 NOTICE 1-2015 GUIDE FOR DYNAMIC POSITIONING SYSTEMS.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、 GUIDE FOR DYNAMIC POSITIONING SYSTEMS NOVEMBER 2013 NOTICE NO. 1 September 2015 The following Changes become EFFECTIVE AS OF 1 SEPTEMBER 2015. (See http:/www.eagle.org for the consolidated version of the Guide for Dynamic Positioning Systems 2013, with all Notices and Corrigenda incorporated.) Note
2、s - The date in the parentheses means the date that the Rule becomes effective for new construction based on the contract date for construction, unless otherwise noted. (See 1-1-4/3.3 of the ABS Rules for Conditions of Classification (Part 1).) SECTION 5 CONTROL SYSTEMS (Revise Subsection 5/15, as f
3、ollows:) 15 Display and Monitoring (1 September 2015) The DP control station is to receive alarms and warnings reflecting the status of the DP system. If the vessel exceeds preset position and heading limits an alarm is to be initiated. If the alarms in the DP control station are slave signals of ot
4、her alarm systems, there are to be a local acknowledgement and silencing device. The silencing device is not to inhibit new alarms. The display unit is to present a position plot including the location of the vessel relative to the reference sources. The plot may be vessel relative, or a true motion
5、 presentation. For DP control systems designed with redundancy, there is to be at least two independent position displays. If the display is used for presentation of warnings or alarms, they are to have priority over other information and they are not to be inhibited by other data currently being di
6、splayed. The critical DP alarms and displays are to be available in DPS-3 backup DP control station. Non-critical DP alarms (e.g., grouping of alarms, logging on by authorized crew only to the alarm monitoring system, etc.) are to be of non-intrusive type announcements for the DP operator, since in
7、a fire or loss of compartment situations, many failed electrical systems, thrusters and other alarms may be initiated simultaneously. ABSGUIDE FOR DYNAMIC POSITIONING SYSTEMS .2013 1 Notice No. 1 September 2015 SECTION 6 AUXILIARY SYSTEMS (APPLIED TO DPS-2 AND DPS-3 (Revise Subsection 6/3, as follow
8、s:) 3 Fuel Oil (1 September 2015) The fuel system is to be arranged to follow the redundancy concept. The duty pump is to be powered from within the same redundancy group as the component or system it serves. The effect of pump failure is not to exceed the WCFDI. If the fuel system requires heating,
9、 then the heating system is to be designed with the appropriate level of redundancy. The design of the fuel system is to facilitate isolation of services between DP operation and industrial functions if applicable. Actuators for quick closing valves are to be installed on a per engine basis and henc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ABS191NOTICE12015GUIDEFORDYNAMICPOSITIONINGSYSTEMSPDF

链接地址:http://www.mydoc123.com/p-400729.html