BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研.pdf
《BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研.pdf》由会员分享,可在线阅读,更多相关《BS PD CLC TR 50627-2015 Study Report on Electromagnetic Interference between Electrical Equipment Systems in the Frequency Range Below 150 kHz《150 kHz以下频率范围内电气设备 系统间电磁干扰的研.pdf(88页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards Publication Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz PD CLC/TR 50627:2015National foreword This Published Document is the UK implementation of CLC/TR50627:2015. The UK participation in its preparation was ent
2、rusted to Technical Committee PEL/205, Mains signalling. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The
3、British Standards Institution 2015. Published by BSI Standards Limited 2015 ISBN 978 0 580 85332 6 ICS 33.100.01 Compliance with a British Standard cannot confer immunity from legal obligations. This Published Document was published under the authority of the Standards Policy and Strategy Committee
4、on 31 December 2015. Amendments/corrigenda issued since publication Date Text affected PUBLISHED DOCUMENT PD CLC/TR 50627:2015 TECHNICAL REPORT RAPPORT TECHNIQUE TECHNISCHER BERICHT CLC/TR 50627 November 2015 ICS 33.100.01 English Version Study Report on Electromagnetic Interference between Electric
5、al Equipment/Systems in the Frequency Range Below 150 kHz Rapport dtude sur les perturbations lectromagntiques entre les quipements / systmes lectriques entre eux dans la plage des frquences infrieure 150 kHZ Studienbericht ber elektromagnetische Interferenz zwischen elektrische Betriebsmittel/Syste
6、me im Frequenzbereich unter 150 kHz This Technical Report was approved by CENELEC on 2015-11-02. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France,
7、Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. European Committee for Electrotechnical Standardization Comit Europen de Normali
8、sation Electrotechnique Europisches Komitee fr Elektrotechnische Normung CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CENELEC All rights of exploitation in any form and by any means reserved worldwide for CENELEC Members. Ref. No. CLC/TR 50627:2015 E PD CLC/TR 50627:2015CLC/
9、TR 50627:2015 (E) 2 Contents Page European foreword 4 Introduction 5 1 Scope 6 2 General 6 3 The frequency range from 2 kHz to 150 kHz . 8 3.1 Challenges in terms of EMI . 8 3.2 Frequency utilization . 10 3.3 The impact of voltage / current shapes . 12 3.4 Interaction of equipment . 16 4 Emissions,
10、measurement and test results 16 4.1 General 16 4.2 Noise measured in a block of flats 17 4.3 Lighting equipment . 17 4.3.1 General 17 4.3.2 Compact lamps 17 4.3.3 Fluorescent lamps . 18 4.3.4 LEDs 19 4.4 Portable mains powered tools 20 4.5.1 General 21 4.5.2 Austrian lab tests on inverters . 22 4.5.
11、3 Active Infeed Converters 22 4.5.4 PV inverters 24 4.5.5 Italian lab and field measurements 25 4.5.6 Power electronics in an Intelligent Distribution Station 27 4.6 Power supplies. 28 4.6.1 General 28 4.6.2 Power supply with PLC signal on DC side 28 4.6.3 Power supply of a TV receiver 28 4.6.5 Powe
12、r supplies in communication technology 29 4.7 Other equipment Rectifier in a cell tower . 31 5 EMI cases, measurement and test results 32 5.1 General 32 5.2 EMI due to conducted emissions . 33 5.2.1 EMI to lighting equipment . 33 5.2.2 EMI to electricity meters . 33 5.2.3 EMI to mains communicating
13、systems (MCS) 34 5.2.4 EMI to medical equipment 50 6 Standardization for the frequency range 2 kHz to 150 kHz. Conformity and time . 57 6.1 Standardization situation 57 6.2 Conformity and time 62 7 Options for improved safeguarding EMC . 62 7.1 For equipment / systems in general 62 7.1.1 Filter appl
14、ication 62 7.1.2 Move from PLC to RF 63 7.1.3 Frequency allocation management 63 7.1.4 Move to broadband lines 64 7.1.5 Notching on transmitter side vs. selectivity on receiver side . 65 7.2 For PLC in particular Move to higher frequencies. 67 8 Conclusions . 69 PD CLC/TR 50627:2015CLC/TR 50627:2015
15、 (E) 3 9 Recommendations . 74 Annex A (informative) Acronyms and abbreviations . 77 Bibliography . 80 PD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 4 European foreword This document (CLC/TR 50627:2015) has been prepared by CLC/SC 205A “Mains communicating systems“. Attention is drawn to the possibility
16、that some of the elements of this document may be the subject of patent rights. CENELEC and/or CEN shall not be held responsible for identifying any or all such patent rights. This document has been prepared under a mandate given to CENELEC by the European Commission and the European Free Trade Asso
17、ciation. This Technical Report provides useful information for standards related to the following European Mandate(s): M/441, M/490. This Technical Report is based on the Study Report “Electromagnetic Interference between Electrical Equipment / Systems in the Frequency Range below 150 kHz” of SC 205
18、A (SC 205A/Sec0339/R:April 2013) (second edition) 1b, with some update according to the developments that have taken place since. PD CLC/TR 50627:2015CLC/TR 50627:2015 (E) 5 Introduction In April 2010, CLC/SC 205A 1)published their first Study Report on “Electromagnetic Interference between Electric
19、al Equipment in the Frequency Range below 150 kHz” 1a. Related studies had been made and information gathered due to first cases of EM interference, with Touch-dimmer lamps (TDLs) as an EMI victim, an inverter as an EMI source, and automated meter reading systems using powerline communication (AMR-
20、PLC) figuring as EMI victims as well as sources. Following this first CLC/SC 205A Study Report, its second edition 1b and, based on it, this Technical Report aims at: a) highlighting the broad relevance of recognized electromagnetic interference for safeguarding EMC also in the frequency range 2 kHz
21、 150 kHz; b) extending knowledge about: 1) EMI cases having been observed between electrical equipment in the frequency range 2 kHz to 150 kHz, with an emphasis on interference between: i) electrical equipment and its non-intentional emissions (NIE); ii) mains communicating systems (MCS) using (powe
22、rline communication) PLC technology with intentional signal injection for the transmission of information over the electricity supply network; 2) different mechanisms causing interference to electrical equipment due to non-intentional or intentional voltage/current components in the considered frequ
23、ency range; as a basis for evaluating the need for closing the recognized gap in standardization as highlighted in the first edition, and considering the recent developments; that: c) without evaluating certain types of electrical equipment concerning applied technology or priority; d) and with rega
24、rd to: 1) problems having occurred with operational equipment of distribution network operators (DNOs), in particular related to smart metering and smart grids control and monitoring equipment; 2) complaints by network users to deliverers and subsequently by deliverers to DNOs or by network users di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDCLCTR506272015STUDYREPORTONELECTROMAGNETICINTERFERENCEBETWEENELECTRICALEQUIPMENTSYSTEMSINTHEFREQUENCYRANGEBELOW150KHZ150KHZ

链接地址:http://www.mydoc123.com/p-397586.html