1、Application of IR Raman Spectroscopy,3 IR regions Structure and Functional GroupAbsorption IR Reflection IR Photoacoustic IR IR Emission Micro,Mid-IR,Mid-IR absorption Samples Placed in cell (salt) Combined with oil Need cell that does not absorb IR KBr, NaCl Tends to absorb water Gases Solutions So
2、lvent issues Dissolution of cell,Analysis,Can calculate group frequencies C-H, C=O, C=C, O-H Variations of frequencies for group Fingerprint region Compare to standards Absorption of inorganics Sulphate, phosphate, nitrate, carbonate Search spectra against library,Mid-IR,Interpretation,Alcohols and
3、amines display strong broad O-H and N-H stretching bands in the region 3400-3100 cm-1 bands are broadened due to hydrogen bonding and a sharp non-bonded peak can around 3400 cm-1 . Alkene and alkyne C-H bonds display sharp stretching absorptions in the region 3100-3000 cm-1 bands are of medium inten
4、sity often obscured (i.e., OH). Triple bond stretching absorptions occur in the region 2400-2200 cm-1 Nitriles are generally of medium intensity and are clearly defined Alkynes absorb weakly unless they are highly asymmetric symmetrical alkynes do not show absorption bands Carbonyl stretching bands
5、occur in the region 1800-1700 cm-1 bands are generally very strong and broad Carbonyl compounds (acyl halides, esters) are generally at higher wave number than simple ketones and aldehydes amides are the lowest, absorbing in the region 1700-1650 cm-1 Carbon-carbon double bond stretching occurs in th
6、e region around 1650-1600 cm-1 bands are generally sharp and of medium intensity Aromatic compounds will display a series of sharp bands Carbon-oxygen single bonds display stretching bands in the region 1200-1100 cm-1 bands are generally strong and broad,Quantitative IR,Difficult to obtain reliable
7、quantitative data based on IR Deviations from Beers law Narrow Bands and wide slit widths required Require calibration sources Complex spectra Weak beam Lack of reference cell Need to normalize refraction Take reference and sample with same cell,Other methods,Reflectance IR Measurement of absorbance
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
2000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- APPLICATIONOFIRRAMANSPECTROSCOPYPPT