《ASTM F2419-11(2017) Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring.pdf》由会员分享,可在线阅读,更多相关《ASTM F2419-11(2017) Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation of the Surface to Receive Resilient Flooring.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2419 11 (Reapproved 2017)Standard Practice forInstallation of Thick Poured Gypsum ConcreteUnderlayments and Preparation of the Surface to ReceiveResilient Flooring1This standard is issued under the fixed designation F2419; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the installation and preparatio
3、n ofthe thick poured gypsum concrete underlayments over woodstructural panel subfloors in commercial structures or overconcrete floors in commercial structures and the preparation ofthe thick poured gypsum concrete underlayment surface priorto the installation of resilient flooring in commercial bui
4、ldings.1.2 This practice covers the factors that are required to becontrolled while installing thick poured gypsum concreteunderlayment as a base for resilient flooring.1.3 This practice does not cover the structural adequacy ofthe wood structural panel subfloor or concrete subfloor. Thestructural i
5、ntegrity of assemblies is governed by local buildingcodes.1.4 This practice does not supersede in any manner the thickpoured gypsum concrete underlayment manufacturers, adhe-sive manufacturers or resilient flooring manufacturers writteninstructions. Consult the individual manufacturer for specificre
6、commendations.1.5 Thick poured gypsum concrete underlayments are notsuitable for use on concrete slabs on ground due to potentialmoisture problems arising from moisture intrusion, unless anadequate vapor retarder or vapor barrier is present directlybeneath the concrete subfloor.1.6 The values stated
7、 in inch-pound units are to be regardedas standard. The values stated in parentheses are approximatemathematical conversions to SI units, which are provided forinformation only.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsi
8、bility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.8 This international standard was developed in accor-dance with internationally recognized principles on standard-izatio
9、n established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C472 Test Methods for Physical Testing of Gypsum, Gyp-su
10、m Plasters and Gypsum ConcreteD4263 Test Method for Indicating Moisture in Concrete bythe Plastic Sheet MethodF141 Terminology Relating to Resilient Floor CoveringsF1482 Practice for Installation and Preparation of PanelType Underlayments to Receive Resilient Flooring3. Terminology3.1 DefinitionsDef
11、initions used in this practice shall be inaccordance with Terminology F141.3.2 Definitions of Terms Specific to This Standard:3.2.1 fully adhered flooring, nresilient flooring which hasadhesive under the entire product, bonding it to the underlay-ment surface. F14823.2.2 non-fully adhered flooring,
12、nresilient flooring thatmay be loose laid, in which no adhesive is utilized, or partiallybonded to the surface of the underlayment, typically at seamsand the surrounding perimeter of the product. F14823.2.3 subfloor, nthat wood or concrete structural layerintended to provide support for design loads
13、 which may receiveresilient floor coverings directly if the surface is appropriate orindirectly via an underlayment if its surface is not suitable or ifunderlayment is required by appropriate code authorities.3.2.4 gypsum concrete underlayment, nthat layer ofmaterial, with binder content composed pr
14、imarily of gypsum1This practice is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.40 onPractices.Current edition approved Dec. 15, 2017. Published January 2018. Originallyapproved in 2005. Last previous edition approved i
15、n 2011 as F2419-11. DOI:10.1520/F2419-11R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM In
16、ternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standard
17、s, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1cement and Portland cement that is mixed with sand and water,then pumped and poured in a liquid state to be installed on orover a subfloor to provide a monolithic surface suitable torece
18、ive resilient floor coverings.3.2.5 thick poured gypsum concrete underlayment,nproducts which are installed in a liquid state over astructurally sound concrete or precast subfloor at a minimum of12 in. (13 mm) or a structurally sound wood subfloor at aminimum of34 in. (19 mm) which when dry form an
19、integralpart of the floor ceiling assembly for fire resistance and soundratings, satisfy building codes for thick poured gypsum con-crete underlayments, and provide a suitable floor surface forthe installation of resilient floor coverings.3.2.6 sound mat, na membrane installed between a struc-turall
20、y sound subfloor and a thick poured gypsum concreteunderlayment to increase sound reduction in the floor ceilingassembly.4. Significance and Use4.1 This practice provides minimum recommendations forthe installation of thick poured gypsum concrete floor under-layments suitable to receive resilient fl
21、oor coverings. Thispractice establishes the proper preparation, installation andquality control for thick poured gypsum concrete floor under-layments.4.2 Actual requirements for thick poured gypsum concreteunderlayments are generally included as part of project plans orspecifications and may vary fr
22、om the recommendations setforth in this practice. Project plans or specifications, or both,shall supersede the recommendations set forth in this practice.5. Product Requirements5.1 For the purposes of this practice, thick poured gypsumconcrete underlayment shall be compounds consisting primar-ily of
23、 a mixture of gypsum cement, Portland cement and sand.5.2 When tested in accordance with Test Methods C472,thick poured gypsum concrete underlayment shall have aminimum compressive strength of 2000 psi (13.8 MPa) for useover wood subfloor and 3000 psi (20.7 MPa) for use overconcrete subfloors.5.3 Wh
24、en tested in accordance with Test Methods C472, thedensity shall be a minimum of 105 pcf (1680 kg/m3).6. Storage and Handling of Thick Poured GypsumConcrete Underlayments6.1 Thick poured gypsum concrete underlayments includedin this practice are typically delivered to the jobsites as drypowder in ba
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM F2419 11 2017 Standard Practice for Installation of Thick Poured Gypsum Concrete Underlayments and Preparation the Surface to Receive Resilient Flooring

链接地址:http://www.mydoc123.com/p-288041.html