1、Designation: C1026 13 (Reapproved 2018)Standard Test Method forMeasuring the Resistance of Ceramic and Glass Tile toFreeze-Thaw Cycling1This standard is issued under the fixed designation C1026; the number immediately following the designation indicates the year oforiginal adoption or, in the case o
2、f revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the procedures and equip-ment required to test either glazed or ung
3、lazed ceramic or glasstiles for resistance to repeated cycles of freezing and thawing.Tiles of any size or shape may be tested by this test method.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard do
4、es not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This internatio
5、nal standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Commit
6、tee.2. Referenced Documents2.1 ASTM Standards:C242 Terminology of Ceramic Whitewares and RelatedProducts23. Summary of Test Method3.1 Adesignated test load of tile specimens is saturated withwater prior to being placed face-up in a metal water-filledcontainer inside a freezer. The water level is adj
7、usted such thatthe tile specimens are partially submerged. A thermocouple isinserted into the bottom of the metal container such that thewater surrounding the thermocouple is the last location tofreeze and thaw. Freezing is followed by a thawing cycle usingwater that flows over the test load. The nu
8、mber of freeze-thawcycles is recorded and after 300 cycles, the test load is visuallyexamined for damage and checked for total weight loss.4. Significance and Use4.1 The test for resistance to freezing and thawing functionsas a guide to the selection of ceramic and glass tiles suitable foroutdoor se
9、rvice in geographic areas subjected to freezing. Itcan serve as a test method to verify compliance with specifi-cations for ceramic and glass tiles, and provides a control testfor determining the freeze/thaw resistance of tiles beingmanufactured for exterior installations.5. Apparatus5.1 Freezing Ch
10、amber. The freezing chamber for this testmethod may be of any type provided it has the capacity to coolthe test load to 27 612 F (-3 614 C) within a period of 3to 6 h. By adjusting the mass of the test load, any freezer canbe used in this test as long as a 3- to 6-h period to reach 27 612 F (-3 614
11、C) is achieved. See Figs. 1 and 2.5.2 Freezing Container. A freezing container of such designand shape that it fits inside the freezing chamber and will allowthe test specimens to be laid flat on a tile support rack at thebottom of the container. The freezing container may be of anyconvenient size o
12、r shape (a stainless steel sink works well). Itmust have a low point in which the thermocouple can besecurely located such that the water around the thermocouplefreezes last (typically near the bottom center of the container).The water level inside the container is maintained throughoutthe test by a
13、djusting the height of an overflow drain. See Fig.3.5.3 Tile Support Rack. A rack capable of supporting the testspecimens a minimum of14 in. (6 mm) above the bottom of thefreezing container in a consistent, level manner. It should berustproof, unaffected by freeze/thaw cycling and with sufficientope
14、nings that the thawing water passes easily over and aroundthe frozen tile specimens during the thawing cycle. See Fig. 4.5.4 Water Reservoir. A reservoir of sufficient volume, inwhich water is maintained at a temperature of 60 6 20F (166 11C) and used to raise the temperature of the test load to 406
15、12 F (5 614 C) during the thawing cycle. See Fig. 5.5.5 Water Pump. A low-pressure water pump of sufficientcapacity to pump water from the water reservoir into the1This test method is under the jurisdiction ofASTM Committee C21 on CeramicWhitewares and Related Productsand is the direct responsibilit
16、y of SubcommitteeC21.06 on Ceramic Tile.Current edition approved Feb. 1, 2018. Published February 2018. Originallypublished in 1984. Last previous edition approved in 2013 as C1026 13. DOI:10.1520/C1026-13R18.2Annual Book of ASTM Standards, Vol 15.02.Copyright ASTM International, 100 Barr Harbor Dri
17、ve, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations is
18、sued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1freezing chamber in such manner that it can flood water overthe test load.Aflow or pressure reduction valve may need to beinstalled between the water pump and the flooding assembly toprevent spraying. See Fig. 6.5.6 Fl
19、ooding Assembly. PVC pipe or similar which as-sembled to spread thawing water throughout the freezingcontainer. Holes18 in. (3 mm) in diameter are drilled in thebottom of the flooding assembly. Holes14 in. (6 mm) indiameter are drilled in the top to maintain the flow of water inthe event the bottom
20、holes become frozen. No holes shall bedrilled in the flooding assembly which would allow water tofall directly on the thermocouple. See Figs. 7-9.FIG. 1 Freezing Chamber, Front ViewC1026 13 (2018)25.7 Controller. A device capable of receiving input from athermocouple and accurately measuring and dis
21、playing thetemperature of the water around the thermocouple within12 F(14 C). The controller must have an electric relay triggered byFIG. 2 Freezing Chamber, Top ViewIncludes Inlet Hose from Water Pump and Control Box Housing the Temperature Controller and Cycle CounterFIG. 3 Freezing ContainerInclu
22、des Low Point for the Thermocouple and Adjustable Overflow Drain in the CornerC1026 13 (2018)3FIG. 4 Freezing Container with Tile Support Rack InstalledFIG. 5 Water Reservoir, Includes Water Line Which Goes Through the Top of the FreezerC1026 13 (2018)4change in temperature to engage and disengage t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM C1026 13 2018 Standard Test Method for Measuring the Resistance of Ceramic and Glass Tile to Freeze Thaw Cycling

链接地址:http://www.mydoc123.com/p-286733.html