IEEE C57.105-1978 Guide for Application of Transformer Connections in Three-Phase Distribution Systems《三相配电系统变压器连接应用指南》.pdf
《IEEE C57.105-1978 Guide for Application of Transformer Connections in Three-Phase Distribution Systems《三相配电系统变压器连接应用指南》.pdf》由会员分享,可在线阅读,更多相关《IEEE C57.105-1978 Guide for Application of Transformer Connections in Three-Phase Distribution Systems《三相配电系统变压器连接应用指南》.pdf(39页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE C57.105-1978 (R2008)IEEE Guide for Application of Transformer Connections in Three-Phase Distribution SystemsSponsorTransformers Committeeof theIEEE Power Engineering SocietyApproved 2 June 1977Reaffirmed 11 June 1987Reaffirmed 18 June 1992Reaffirmed 27 March 2008Institute of Electrical and Ele
2、ctronics EngineersSecretariatEdison Electric InstituteInstitute of Electrical and Electronics EngineersNational Electric Manufacturers AssociationApproved May 19, 1978Approved March 2, 1989American National Standards InstitutePublished byThe Institute of Electrical and Electronics Engineers, Inc 345
3、 East 47th Street, New York, NY 10017No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without theprior written permission of the publisher.American National StandardAn American National Standard implies a consensus of those substantially conc
4、erned with its scope and provisions.An American National Standard is intended as a guide to aid the manufacturer, the consumer, and the general public.The existence of an American National Standard does not in any respect preclude anyone, whether he has approved thestandard or not, from manufacturin
5、g, marketing, purchasing, or using products, processes, or procedures notconforming to the standard. American National Standards are subject to periodic review and users are cautioned toobtain the latest editions.CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time
6、. The procedures ofthe American National Standards Institute require that action be taken to reaffirm, revise, or withdraw this standard nolater than five years from the date of publication. Purchasers of American National Standards may receive currentinformation on all standards by calling or writi
7、ng the American National Standards Institute. Copyright byThe Institute of Electrical and Electronics Engineers, IncNo part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without theprior written permission of the publisher.iiiForeword(This Forewor
8、d is not a part of ANSI/IEEE C57.105-1978, American National Standard Guide for Application of TransformerConnections in Three-Phase Distribution Systems.)In the fall of 1968, a Working Group was formed by the Performance Characteristics Subcommittee of the IEEETransformers Committee to prepare a us
9、ers guide for application of Y-Y transformers considering user systems,manufacturing capabilities, tank heating, ferroresonance and telephone interference. The scope of the proposed usersguide was subsequently expanded to cover the full range of transformer connections commonly used in 3-phasedistri
10、bution systems with emphasis on those characteristics of connections which distinguish one from another, appearmost prominently with asymmetrical system conditions, and affect the selection of connections.The guide assumes the reader has an educational or practical background equivalent to that of a
11、 graduate electricalengineer with some knowledge of transformers and distribution practices. Recognizing from the start, however, thatthe guide would be most needed by and most useful to the engineer with relatively little experience, the WorkingGroup has incorporated explanatory material where cons
12、idered to be helpful.The Institute wishes to acknowledge its indebtedness to those who have given so freely of their time and knowledge tothe development of this guide.At the time it approved this standard, C57 had the following membership:H. D. Lewis, Chair C. R. Wilmore, Secretary Bonneville Power
13、 Administration George W. IliffElectric Light and Power Group R. R. BestI. O. BerkhanI. H. KoponenJ. P. Markey (Alt)P. H. PhilippidisW. A. RichterB. F. SmithE. A. VillasusoInstitute of Electrical and Electronics Engineers .S. BennonW. P. BurtJ. C. DuttonD. C. Johnson (Alt)L. W. LongD. E. MasseyNaval
14、 Facilities Engineering Command Leonard W. JohnsonNational Electrical Manufacturers Association L. C. AicherW. R. CourtadeJ. D. DouglassW. C. KendallG. W. Mayall (Alt)W. J. McNuttNorman M. Neagle (Alt)R. L. SchwabR. E. Uptegraff, JrG. C. Wilburn (Alt)Rural Electrification Administration J. C. Arnold
15、, JrTennessee Valley Authority L. R. SmithUnderwriters Laboratories W. A. Farquhar (Alt)ivE. J. HuberU. S. Bureau of Reclamation R. H. RichardsonThis guide was developed by a Working Group of the Performance Characteristics Committee of the IEEETransformers Committee of the IEEE Power Engineering So
16、ciety which had the following membership:L. W. Long, Chair J. D. BorstD. E. MasseyK. M. McWilliamsD. A. RoachD. R. SmithOther members who have served in the past are:E. R. Freitag*R. H. HollisterA. M. LockieR. L. MacdonaldR. L. Schmid*First chairmanSpecial acknowledgement is due C. R. French, Chairm
17、an of the Performance Characteristics Subcommittee at the timeof Working Group formation, who saw the need for this work and contributed substantially to the initial efforts.The Transformers Committee of the IEEE Power Engineering Society of 1976 and 1977 reviewed and approved thisstandard.When this
18、 standard was approved June 2, 1977, the IEEE Standards Board had the following membership:William R. Kruesi, Chair Irvin N. Howell, Jr, Vice Chair Ivan G. Easton, Secretary William E. AndrusJean Jacques ArchambaultMark BarberEdward J. CohenWarren H. CookLouis CostrellR. L. CurtisDavid B. DobsonR. O
19、. DuncanCharles W. FlintJay ForsterRalph I. HauserJoseph L. KoepfingerIrving KolodnyBenjamin J. LeonThomas J. MartinDonald T. MichaelVoss A. MooreWilliam S. MorganWilliam J. NeiswenderRalph M. ShowersRobert A. SodermanLeonard W. Thomas, SrB. W. WhittingtonvCLAUSE PAGE1. Scope.12. Electrical Connecti
20、ons 12.1 Primary and Secondary Systems 12.2 and Y Connections 22.3 Zigzag-Connected Winding . 32.4 TT Connections 52.5 Terminal Markings, Phase Relations, and Paralleling . 52.6 Connection of the Neutral 93. Magnetic Circuits 93.1 General Transformer Design 93.2 3-Phase Transformer Core Configuratio
21、n 103.3 Magnetic Circuit Effects on 3-Phase Transformer Behavior. 124. Harmonic Currents and Voltages 134.1 Exciting Current Harmonics 134.2 Harmonic Generation . 134.3 Flow on 3-Phase System 144.4 Telephone Noise 155. Primary Faults .155.1 Types and Clearing of Faults . 155.2 Ground Faults. 155.3 O
22、pen Conductor Faults 166. Unbalanced Loads and Secondary Ground Faults 176.1 Phase-to-Neutral Loads 176.2 Phase-to-Phase Loads 186.3 Secondary Faults 197. Ferroresonance 207.1 Qualitative Description 207.2 Transformer Connections Highly Susceptible to Ferroresonance . 227.3 Measures to Minimize the
23、Probability of Ferroresonance with Ungrounded Primary Connection. 247.4 Transformer Connections Least Susceptible to Ferroresonance 257.5 Measures to Minimize the Probability of Ferroresonance with Grounded Primary Connections . 267.6 Bibliography. 278. Unsymmetrical Banks and Special Connections 27
24、8.1 T-Connected. 278.2 Circulating Delta Currents . 278.3 Grounded Delta Secondary 288.4 Open- Secondary . 308.5 Open-Y primary to 4-Wire 208 V Service. 318.6 Effect on Voltage Balance . 31viCLAUSE PAGE9. References and Bibliography 319.1 General . 319.2 Ferroresonance . 319.3 Special Connections .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEEC571051978GUIDEFORAPPLICATIONOFTRANSFORMERCONNECTIONSINTHREEPHASEDISTRIBUTIONSYSTEMS 三相 配电 系统 变压器

链接地址:http://www.mydoc123.com/p-1366122.html