ISO 7240-17-2009 Fire detection and fire alarm systems - Part 17 Short-circuit isolators《失火探测和失火报警系统 第17部分 短路光电隔离器》.pdf
《ISO 7240-17-2009 Fire detection and fire alarm systems - Part 17 Short-circuit isolators《失火探测和失火报警系统 第17部分 短路光电隔离器》.pdf》由会员分享,可在线阅读,更多相关《ISO 7240-17-2009 Fire detection and fire alarm systems - Part 17 Short-circuit isolators《失火探测和失火报警系统 第17部分 短路光电隔离器》.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO 7240-17:2009(E) ISO 2009INTERNATIONAL STANDARD ISO 7240-17 First edition 2009-08-15 Fire detection and fire alarm systems Part 17: Short-circuit isolators Systmes de dtection dincendie et dalarme Partie 17: Isolateurs de court-circuit ISO 7240-17:2009(E) PDF disclaimer This PDF
2、 file may contain embedded typefaces. In accordance with Adobes licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein
3、the responsibility of not infringing Adobes licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PD
4、F-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT
5、ISO 2009 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in t
6、he country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2009 All rights reservedISO 7240-17:2009(E) ISO 2009 All rights reserved iii Contents Page Foreword
7、 iv Introduction . vi 1 Scope . 1 2 Normative references . 1 3 Terms and definitions. 2 4 Requirements 2 4.1 Compliance 2 4.2 Integral status indication . 2 4.3 Connection of ancillary devices 2 4.4 Monitoring of detachable short-circuit isolators. 3 4.5 Manufacturers adjustments 3 4.6 On-site adjus
8、tments . 3 4.7 Marking 3 4.8 Data 3 4.9 Additional requirements for software controlled short-circuit isolators 4 5 Tests. 5 5.1 General. 5 5.2 Reproducibility 7 5.3 Variation in supply voltage 8 5.4 Dry heat (operational). 8 5.5 Cold (operational) . 9 5.6 Damp heat, cyclic (operational). 10 5.7 Dam
9、p heat, steady state (endurance). 10 5.8 Sulfur dioxide (SO 2 ) corrosion (endurance) 11 5.9 Shock (operational) 12 5.10 Impact (operational) 13 5.11 Vibration, sinusoidal (operational) 14 5.12 Vibration, sinusoidal (endurance). 15 5.13 Electromagnetic compatibility (EMC), immunity tests (operationa
10、l). 16 6 Test report . 17 Annex A (informative) Examples for the functional test procedure 18 Annex B (informative) Apparatus for impact test . 25 Bibliography . 27 ISO 7240-17:2009(E) iv ISO 2009 All rights reservedForeword ISO (the International Organization for Standardization) is a worldwide fed
11、eration of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that comm
12、ittee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accorda
13、nce with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires
14、 approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 7240-17 was prepared by Technical
15、 Committee ISO/TC 21, Equipment for fire protection and fire fighting, Subcommittee SC 3, Fire detection and alarm systems. ISO 7240 consists of the following parts, under the general title Fire detection and fire alarm systems: Part 1: General and definitions Part 2: Control and indicating equipmen
16、t Part 4: Power supply equipment Part 5: Point-type heat detectors Part 6: Carbon monoxide fire detectors using electro-chemical cells Part 7: Point-type smoke detectors using scattered light, transmitted light or ionization Part 8: Carbon monoxide fire detectors using an electro-chemical cell in co
17、mbination with a heat sensor Part 9: Test fires for fire detectors Technical Specification Part 10: Point-type flame detectors Part 11: Manual call points Part 12: Line type smoke detectors using a transmitted optical beam Part 13: Compatibility assessment of system components Part 14: Guidelines fo
18、r drafting codes of practice for design, installation and use of fire detection and fire alarm systems in and around buildings Technical Report Part 15: Point type fire detectors using scattered light, transmitted light or ionization sensors in combination with a heat sensor ISO 7240-17:2009(E) ISO
19、2009 All rights reserved v Part 16: Sound system control and indicating equipment Part 17: Short-circuit isolators Part 18: Input/output devices Part 19: Design, installation, commissioning and service of sound systems for emergency purposes Part 20: Aspirating smoke detectors Part 21: Routing equip
20、ment Part 22: Smoke-detection equipment for ducts Part 24: Sound-system loudspeakers Part 25: Components using radio transmission paths Part 27: Point-type fire detectors using a scattered-light, transmitted-light or ionization smoke sensor, an electrochemical-cell carbon-monoxide sensor and a heat
21、sensor Part 28: Fire protection control equipment A Part 3, dealing with audible alarm devices and a Part 23, dealing with visual alarm devices, are in preparation. ISO 7240-17:2009(E) vi ISO 2009 All rights reservedIntroduction This part of ISO 7240 is based on a European standard EN 54-17, prepare
22、d by the European Committee for Standardization CEN/TC 72 “Fire detection and fire alarm systems”. The purpose of short-circuit isolators is to limit the consequences of low-parallel-resistance faults between the lines of a transmission path of a fire detection and alarm system. This is normally ach
23、ieved by connecting the transmission path in a loop configuration, separating sections of the loop with short-circuit isolators and introducing a means of detecting the presence of a fault, if its consequences (e.g. reduction in the line voltage) jeopardizes the correct operation of components on th
24、e transmission path. The faulty section of the loop can then be switched out, between a pair of short-circuit isolators, allowing the rest of the loop to continue to function correctly. It is recognized that it is not possible for this part of ISO 7240 to specify all of the requirements for the func
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO7240172009FIREDETECTIONANDFIREALARMSYSTEMSPART17SHORTCIRCUITISOLATORS 失火 探测 报警 系统 17 部分 短路 光电 隔离器

链接地址:http://www.mydoc123.com/p-1255239.html