1、INTERNATIONAL STANDARD ISO 4262 Second edition 1993-09-15 Petroleum products - Determination of carbon residue - Ramsbottom method Produits p6 troliers - Dbtermination du r attempt to pass a 2,0 mm diameter drill rod through the capillary. Reject bulbs that do not permit the insertion of the smaller
2、 rod and those whose capillaries are larger than the larger rod. 4.2 Control bulb, for use in determining compliance of furnace characteristics with the Performance re- quirements (see clause 5). Made of stainless steel, containing a thermocouple and conforming to the tol- erances shown in figure 2.
3、 The control bulb shall be provided with a dull finish by heating in a furnace at a temperature of 850 “C to 900 “C for 30 min, and shall not be polished thereafter, as a polished bulb has different heating characteristics from one with a dull finish. Hemispherical inside rradius z 11 mm I I I I I Y
4、 1,4 m c / I I / t I : 1 ii 1 “y/ / / N / -a ,) 252 # 24,2 I Dimensions in millimetres - Capillary length 8 7 - 5 2,0 IS Capillary, free a-a of constrictions A suita ble th te mperature ermocouple pyrometer for within + 1 “C is also requ observ red. ing true Figure 1 - Glass coking bulb 4.3 Syringe,
5、 for test Portion charging. A 5 ml or IO ml glass hypodermic Syringe fitted with a needle of 1,5 mm outside diameter or a Serum needle of 1,45 mm to 1,47 mm outside diameter, for transfer of the test Portion to the glass coking bulb. NOTE 6 A Syringe having a needle which fits on the ground glass ti
6、p of the Syringe is not recommended, as it may be blown off when pressure is applied to the Syringe plunger. Locking-type syringes are more satisfactory, as the needle locks on the bottom of the Syringe barrel, and cannot be blown off by pressure. 4.4 Metal coking furnace, constructed of solid metal
7、, having coking bulb wells 25,45 mm + 0,l mm in internal diameter and 76 mm deep to the centre of the well bottom, with suitable arrangements for heating to a uniform temperature of 550 “C. The bot- tom of the well shall be hemispherical to accommo- date the bottom of the glass coking bulb (4.1). DO
8、 not cast or otherwise form the furnace with un- necessary voids which will impede heat transfer. If a molten metal furnace is used, provide it with a suitable number of bulb wells, the internal dimensions of which correspond to the internal dimensions of holes in the solid metal furnace. The bulb w
9、ells shall be immersed in the molten metal to leave not more than 3 mm of the bulb weil exposed above the molten metal at operating temperatures. NOTE 7 been fou n A description of one type of furnace wh d to be satisfacto ry is given in annex B. ich has 4.5 Temperature-measuring devices. A removabl
10、e iron-constantan thermocouple with a sensitive pyrometer, or other suitable temperature-indicating device shall be used, located centrally near the bot- tom Portion of the furnace and arranged to measure the temperature of the furnace, thus enabling the performante tests specified in clause 5 to be
11、 carried out. NOTES 8 When a molten bath is used, it is desirable to protect the temperature-indicating device with a quartz or thin metal sheath. 9 lt is good practice to calibrate the thermocouple or other temperature-measuring device against a Standard thermocouple or a reference Standard approxi
12、mately once a week when the furnace is in constant use, the actual fre- quency depending on experience. ISO 4262:1993(E) Ceramic insulator with two holes length 64 for thermocouple 0,s mm wires Double glass-lapped and silicone- impregnated 1 500 mm lang with M two holes for thermocouple wires R 0,8
13、7 Dimensions in miliimetres Tolerante on dimensions f 0,4 unless othervvise stated 25,02 ext. 6,4 ! Iron-constantan thermocouple, 0,s mm wires Stainless steel 1 Austenitic stainless Wall thickness 0,9 mm steeL Onforming t” stainless steel ISO 683-13 Threaded Hemispherical outside radius 12,4 mm to 1
14、2,7 mm NOTE - Total mass of control bulb less thermocouple: 24 g k 1 g Figure 2 - Control bulb 5 Verification of apparatus Performance 5.1 General Periodically check the Performance of the furnace (4.4) and temperature-measuring devices (4.5) as de- scribed in 5.2 to 5.4 to ensure that as used they
15、con- form to the requirements of the method. Consider the furnace as having Standard Performance when the operating requirements described are met by each coking bulb well while the bath is fully loaded as well as singly Ioaded. Once these criteria have been met, use the furnace with any degree of l
16、oading. Use only a furnace that has successfully undergone the per- formante or control tests given in this clause. 5.2 Thermocouple Calibrate the thermocouple in the control bulb against a Standard thermocouple at least once every 50 h of use of the control bulb (4.2). NOTE 10 During use at the hig
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO42621993PETROLEUMPRODUCTSDETERMINATIONOFCARBONRESIDUERAMSBOTTOMMETHOD 石油 产品 测定 兰姆斯 波特 RAMSBOTTOM 简称

链接地址:http://www.mydoc123.com/p-1253813.html