ISO 14708-2-2012 Implants for surgery - Active implantable medical devices - Part 2 Cardiac pacemakers《外科植入物 有源可植入医疗装置 第2部分 心脏起搏器》.pdf
《ISO 14708-2-2012 Implants for surgery - Active implantable medical devices - Part 2 Cardiac pacemakers《外科植入物 有源可植入医疗装置 第2部分 心脏起搏器》.pdf》由会员分享,可在线阅读,更多相关《ISO 14708-2-2012 Implants for surgery - Active implantable medical devices - Part 2 Cardiac pacemakers《外科植入物 有源可植入医疗装置 第2部分 心脏起搏器》.pdf(76页珍藏版)》请在麦多课文档分享上搜索。
1、 Reference number ISO 14708-2:2012(E) ISO 2012INTERNATIONAL STANDARD ISO 14708-2 Second edition 2012-08-15 Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers Implants chirurgicaux Dispositifs mdicaux implantables actifs Partie 2: Stimulateurs cardiaques ISO 14708-2:20
2、12(E) COPYRIGHT PROTECTED DOCUMENT ISO 2012 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the add
3、ress below or ISOs member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyrightiso.org Web www.iso.org Published in Switzerland ii ISO 2012 All rights reservedISO 14708-2:2012(E) ISO 2012 All rights
4、reserved iiiContents Page Foreword . v Introduction vi 1 Scope 1 2 Normative references 1 3 Terms and definitions . 2 4 Symbols and abbreviated terms 6 5 General requirements for non-implantable parts . 6 6 Measurements of implantable pulse generator and lead characteristics . 6 6.1 Measurement of i
5、mplantable pulse generator characteristics . 6 6.2 Measurement of the lead pacing impedance (Z p ) 18 7 General arrangement of the packaging . 19 8 General markings for active implantable medical devices . 20 9 Markings on the sales packaging 20 10 Construction of the sales packaging 21 11 Markings
6、on the sterile pack 21 12 Construction of the non-reusable pack 22 13 Markings on the active implantable medical device 23 14 Protection from unintentional biological effects being caused by the active implantable medical device . 24 15 Protection from harm to the patient or user caused by external
7、physical features of the active implantable medical device . 24 16 Protection from harm to the patient caused by electricity 24 17 Protection from harm to the patient caused by heat . 25 18 Protection from ionizing radiation released or emitted from the active implantable medical device . 26 19 Prot
8、ection from unintended effects caused by the device . 26 20 Protection of the device from damage caused by external defibrillators . 27 21 Protection of the device from changes caused by high power electrical fields applied directly to the patient 27 22 Protection of the active implantable medical d
9、evice from changes caused by miscellaneous medical treatments 27 23 Protection of the active implantable medical device from mechanical forces . 27 24 Protection of the active implantable medical device from damage caused by electrostatic discharge 32 25 Protection of the active implantable medical
10、device from damage caused by atmospheric pressure changes 32 26 Protection of the active implantable medical device from damage caused by temperature changes 33 ISO 14708-2:2012(E) iv ISO 2012 All rights reserved27 Protection of the active implantable medical device from electromagnetic non-ionizing
11、 radiation 33 28 Accompanying documentation 33 Annex A A (informative) Relationship between the fundamental principles in ISO/TR 14283 and the clauses of this International Standard 37 Annex B B (informative) Relationship between the clauses of this part of ISO 14708 and the fundamental principles i
12、n Annex A 51 Annex C C (informative) Rationale 52 Annex D D (informative) Code for describing modes of implantable pulse generators 61 Annex E E (informative) Symbols 64 Annex F F (normative) Pulse forms .65 Bibliography 67 ISO 14708-2:2012(E) ISO 2012 All rights reserved vForeword ISO (the Internat
13、ional Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has bee
14、n established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical stand
15、ardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for
16、 voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all
17、 such patent rights. ISO 14708-2 was prepared by Technical Committee ISO/TC 150, Implants for surgery, Subcommittee SC 6, Active implants. This second edition cancels and replaces the first edition (ISO 14708-2:2005), which has been technically revised. ISO 14708 consists of the following parts, und
18、er the general title Implants for surgery Active implantable medical devices: Part 1: General requirements for safety, marking and for information to be provided by the manufacturer Part 2: Cardiac pacemakers Part 3: Implantable neurostimulators Part 4: Implantable infusion pumps Part 5: Circulatory
19、 support devices Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators) The following parts are under preparation: Part 7: Particular requirements for cochlear implant systems ISO 14708-2:2012(E) vi ISO 2012 All
20、 rights reservedIntroduction This part of ISO 14708 specifies particular requirements for those ACTIVE IMPLANTABLE MEDICAL DEVICES intended to treat bradyarrhythmias (PACEMAKERS), to provide basic assurance of safety to both patients and users. An implantable cardiac PACEMAKER is essentially a power
21、ed electronic device within a sealed, encapsulating enclosure (an IMPLANTABLE PULSE GENERATOR). The device can stimulate heart beats by generating electrical impulses which are transmitted to the heart along implanted, insulated conductors with ELECTRODES (LEADS). The PACEMAKER may be adjusted non-i
22、nvasively by an electronic device, known as a programmer. This part of ISO 14708 is relevant to all parts of implantable PACEMAKERS, including all accessories. Typical examples are IMPLANTABLE PULSE GENERATORS, LEADS, ADAPTORS, programmers and the related software. The requirements of this part of I
23、SO 14708 supplement or modify those of ISO 14708-1, referred to as the General Standard. The requirements of this part of ISO 14708 take priority over those of ISO 14708-1. Figures or tables that are additional to those of ISO 14708-1 are numbered starting from 101; additional annexes are lettered A
24、A, BB, etc. Although both this part of ISO 14708 and the Directive 90/385/EEC deal with the same products, the structure and purpose of the two documents are different. Annex AA correlates the requirements of the Directive with the subclauses of ISO 14708-1 and this part of ISO 14708. Annex BB provi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ISO1470822012IMPLANTSFORSURGERYACTIVEIMPLANTABLEMEDICALDEVICESPART2CARDIACPACEMAKERS 外科 植入 有源 医疗 装置 部分

链接地址:http://www.mydoc123.com/p-1251127.html