IEEE 859-1987 en Standard Terms for Reporting and Analyzing Outage Occurrences and Outage States of Electrical Transmission Facilities《报告及分析输电设施发生中断和中断状态用术语》.pdf
《IEEE 859-1987 en Standard Terms for Reporting and Analyzing Outage Occurrences and Outage States of Electrical Transmission Facilities《报告及分析输电设施发生中断和中断状态用术语》.pdf》由会员分享,可在线阅读,更多相关《IEEE 859-1987 en Standard Terms for Reporting and Analyzing Outage Occurrences and Outage States of Electrical Transmission Facilities《报告及分析输电设施发生中断和中断状态用术语》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、IEEE Std 859-1987 IEEE Standard Terms for Reporting and Analyzing Outage Occurrences and Outage States of Electrical Transmission Facilities Published by The Institute of Electrical and Electronics Engineers, Inc 345 East 47th Street, New York, NY 10017, USA February 17,1988 SI11478 Copyright 1988 b
2、yThe Institute of Electrical and Electronics Engineers, Inc.345 East 47th Street, New York, NY 10017, USANo part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the publisher.IEEE Std 859-1987 (R2008)IEEE Stan
3、dard Terms for Reporting and Analyzing Outage Occurences and Outage States of Electrical Transmission FacilitiesSponsorPower System Engineering Committeeof thePower Engineering SocietyReaffirmed 27 March 2008Approved 11 June 1987IEEE Standards BoardIEEE Standards documents are developed within the T
4、echnical Com- mittees of the IEEE Societies and the Standards Coordinating Committees of the IEEE Standards Board. Members of the committees serve volun- tarily and without compensation. They are not necessarily members of the Institute. The standards developed within IEEE represent a consensus of t
5、he broad expertise on the subject within the Institute as well as those activities outside of IEEE which have expressed an interest in participating in the development of the standard. Use of an IEEE Standard is wholly voluntary. The existence of an IEEE Standard does not imply that there are no oth
6、er ways to produce, test, measure, purchase, market, or provide other goods and services related to the scope of the IEEE Standard. Furthermore, the viewpoint expressed at the time a standard is approved and issued is subject to change brought about through developments in the state of the art and c
7、omments received from users of the standard. Every IEEE Standard is subjected to review at least once every five years for revision or reaffirmation. When a document is more than five years old, and has not been reaffirmed, it is reasonable to conclude that its contents, although still of some value
8、, do not wholly reflect the present state of the art. Users are cautioned to check to deter- mine that they have the latest edition of any IEEE Standard. Comments for revision of IEEE Standards are welcome from any inter- ested party, regardless of membership affiliation with IEEE. Suggestions for c
9、hanges in documents should be in the form of a proposed change of text, together with appropriate supporting comments. Interpretations: Occasionally questions may arise regarding the meaning of portions of standards as they relate to specific applications. When the need for interpretations is brough
10、t to the attention of IEEE, the Institute will initiate action to prepare appropriate responses. Since IEEE Standards represent a consensus of all concerned interests, it is important to ensure that any interpretation has also received the concurrence of a balance of interests. For this reason IEEE
11、and the members of its technical commit- tees are not able to provide an instant response to interpretation requests except in those cases where the matter has previously received formal consideration. Comments on standards and requests for interpretations should be addressed to: Secretary, IEEE Sta
12、ndards Board 345 East 47th Street New York, NY 10017 USA Foreword (This Foreword is not a part of BEE Std 859-1987, IEEE Standard Terms for Reporting and Analyzing Outage Occur- Data on outage occurrences of transmission facilities have been collected for many years. Initially, reporting was general
13、ly limited to reporting frequency of outage occurrence on transmission lines. Total outage frequency was classified into several general cause categories, but there were no formal definitions for the events and statistics reported beyond those contained in the data forms and instructions. Early effo
14、rts did not generally collect data on outage duration, except to class outages as temporary or permanent according to type of restoration used. In the 1960s, methods were first proposed for calculating reliability of transmission and distribution “systems” (networks) in terms of the reliability of t
15、heir individual “components? This led to the need for more formal definitions of terms to foster uniformity and standardization of language among engineers engaged in reporting, analyzing, and predicting outages of transmission and distribution facilities and interruptions to customers. This resulte
16、d in development of IEEE Std 346-1973, IEEE Standard Defini- tions in Power Operations Terminology Including Terms for Reporting and Analyzing Outages of Electri- cal Transmission and Distribution Facilities and Interruptions to Customer Service. More recent developments have shown the need to inclu
17、de definitions for a broader scope of outage events. For example, two general categories of facilities (reportable entities) must be recognized to support presently available models. In one type of model, a transmission system is partitioned function- ally into “units” which represent the capability
18、 to transfer power between specified points. In the second type of model, a system is partitioned physically into “components? Another recent development is the increasing recognition of the importance of “related outage occur- rences” in which outage occurrences of two or more facilities are relate
19、d in some way due to the physical construction of equipment (such as common structure), the electrical interconnection of equipment (common bus, for example), or exposure to a common environment (storms). Achieving clear and unambiguous definitions for related outage occurrences is important for rep
20、orting outage occurrences at the transmission unit level. At the component level, an important consideration is the recognition of several modes of failure, particularly for switching, protection, and automatic reclosing equipment. No attempt is made here to standardize procedures for the collection
21、 of outage data. What is at- tempted is to speclfy certain common terms and indices to provide a basis of information exchange. The task force has attempted to keep the list of terms and indices as brief as possible. The indices defined here are intended to serve as estimates for parameters of model
22、s which are used in transmission system reliability evaluation. The indices may also be used directly to guide system opera- tion or in assessment of equipment performance. No attempt is made to recommend acceptable equip- ment reliability levels. This is a revision of IEEE Std 346-1973. However, te
23、rms related to distribution system facilities and interruptions were eIiminated from the scope of this document. This document was prepared by the Transmission and Distribution Outage and Interruption Defini- tions Task Force. This task force was formed by the PROSD (Performance Records for Optimizi
24、ng System Design) Working Group, which is under the guidance of the Power System Engineering Committee. The members of the task force were: rences and Outage States of Electrical Transmission Facilities.) P. F. Albrecht R. N. Allan M. P. Bhavaraju M. G. Lauby (Chairman) R. Billinton D. W. Forrest G.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- IEEE8591987ENSTANDARDTERMSFORREPORTINGANDANALYZINGOUTAGEOCCURRENCESANDOUTAGESTATESOFELECTRICALTRANSMISSIONFACILITIES

链接地址:http://www.mydoc123.com/p-1248965.html